Lincoln ElectricメーカーIM723-Aの使用説明書/サービス説明書
ページ先へ移動 of 29
R IP 21S NTRL/C UNDER-COOLER CAR T OPERA TOR’S MANUAL IM723-A January, 2004 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation .
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
iv SAFETY iv Mar. ‘93 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1.
v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
vi T ABLE OF CONTENTS Page Installation ................................................................................................................... ....Section A Technical Specifications ........................................................
A-1 INST ALLA TION UNDER-COOLER CART A-1 TECHNICAL SPECIFICA TIONS – UNDER- W A TER COOLER Model / Make Under-Cooler Cart K1828-1 Input 100-120 VAC 50/60 Hz 1 Phase Rated Current Draw 60 Hz (2.8-3.5 Amps) 50 Hz (3.5-5.3 Amps) Operating Pressure 60 psig (413 kPa) (4.
SAFETY PRECAUTIONS: ELECTRIC SHOCK Can Kill • Only qualified persons should per- form this installation. HOT COOLANT CAN BURN SKIN • Always be sure coolant is not hot before doing any work on cooler parts. ROT A TING F AN BLADES ARE HAZARDOUS • Do not put your hands near an oper- ating fan.
A-3 INST ALLA TION UNDER-COOLER CART A-3 NOTE: D O NOT ADD MORE THAN 2 GALLONS (7.6 LITERS) OF COOLANT INTO THE RESER- VOIR. The fill cap contains a pressure release air hole, which must not be blocked by overfilling the reservoir with coolant.
A-4 INST ALLA TION UNDER-COOLER CART A-4 INPUT POWER CONNECTION Plug the input power cord on the Under-Cooler cart into the standard bottom 115V NEMA circuit breaker protected receptacle, located on the back of the Precision TIG machine.
A-5 INST ALLA TION UNDER-COOLER CART A-5 CONNECTION OF TIG TORCHES Installation of TIG torches to be used with this Precision TIG Under-Cooler cart is explained in the Precision TIG machine literature. The torch does not directly attach to the cooler but through a connection box mounted on the TIG machine.
B-1 OPERA TION UNDER-COOLER CART B-1 SAFETY PRECAUTIONS GENERAL DESCRIPTION The Under-Cooler cart is an internal type, re-circula- tion cooling system designed for use with water- cooled TIG torches.
B-2 OPERA TION B-2 TURNING THE SYSTEM "ON" After connecting the Precision Tig and Tig Torches per Installation Section, plug the unit into a 115V NEMA electrical receptacle for start-up operation. Be certain that the power input into the unit matches the Cooler's rated input.
D-1 MAINTENANCE D-1 PUMP The pump head has a "built in" strainer on the inlet side of the pump. It is recommended to clean or replace the pump’s inlet strainer at least annually as follows: • Drain the coolant reservoir and all coolant lines.
D-2 MAINTENANCE D-2 RESERVOIR COOLANT LEVEL The reservoir volume should be checked daily before using the cooler. Remove the reservoir fill cap and check the coolant level. The reservoir is full when the coolant level is just below the input elbow of the reser- voir (approximate.
D-3 MAINTENANCE D-3 Disinfect the cooling system: • Prepare the disinfectant: Make a quantity of only is needed to avoid an excess. • Bulk preparation (for coolers serviced in quantity): 2.325 gals. (8.775 liters) of pure, fresh water per cooler 1.
D-4 MAINTENANCE D-4 Service the pump’s inlet strainer: a. Place absorbent towels underneath pump head to prevent stray coolant from wetting cooler’s electrical components. b. Hold pump head to apply counter torque when loos- ening strainers 7/8 acorn nut.
E-1 TROUBLESHOOTING E-1 UNDER-COOLER CART If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2 TROUBLESHOOTING E-2 UNDER-COOLER CART Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
F-1 WIRING DIAGRAM F-1 UNDER-COOLER CART NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
F-2 DIAGRAM F-2 UNDER-COOLER CART M19724 3 - 0 1 HEAT "IN" W ELDING TORCH OR GUN HEAT EXCHANGER FAN AIR FLOW PUMP COOLANT RESERVOIR K1828-1 U nder-Cooler Ca rt Wate r Cooler Flow Diagram COO.
F-3 DIMENSION PRINT F-3 UNDER-COOLER CART M19757 B (27.16) (16.34) (22.25) (22.84) (20.94) (12.20) (40.96) (23.32) (19.94) (13.35) (20.94) NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels.
NOTES UNDER-COOLER CART.
NOTES UNDER-COOLER CART.
NOTES UNDER-COOLER CART.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS PAR TES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
デバイスLincoln Electric IM723-Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lincoln Electric IM723-Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLincoln Electric IM723-Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lincoln Electric IM723-Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lincoln Electric IM723-Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lincoln Electric IM723-Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLincoln Electric IM723-Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lincoln Electric IM723-Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLincoln Electric IM723-Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。