Lincoln ElectricメーカーIM724の使用説明書/サービス説明書
ページ先へ移動 of 45
SP- 135T OPERA TOR’S MANUAL IM724 April, 2001 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part.
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
iv SAFETY iv PRÉCA UTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instruc- tions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suivantes: Sûreté Pour Soudage A L’Arc 1.
Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
vi MASTER T ABLE OF CONTENTS FOR ALL SECTIONS Page Installation .......................................................................................................Section A Technical Specifications .................................................
A-1 SP-135T A-1 Fuse or Output Mode Input Voltage Breaker Size 1 Input Amps Power Cord Extension Cord Three Conductor #14 AWG (2.1 mm 2 ) or Larger RATED 120V/60Hz 20 Amp 20 15 Amp, 125V, Up to 25 Ft. (7.6 mm) Three Prong Plug Three Conductor (NEMA Type 5-15P) #12 AWG (3.
A-2 INST ALLA TION SP-135T A-2 Read entire installation section before starting installation. SAFETY PRECA UTIONS IDENTIFY AND LOCA TE COMPONENTS If you have not already done so, unpack the SP-135T from its carton and remove all packing material around the SP-135T.
A-3 INST ALLA TION SP-135T A-3 SP-135T 4 5 8 3 6 7 1 2 DO NOT SWITCH DO NOT SWITCH WHEN WELDING WHEN WELDING + - FIGURE A.2 W ork Clamp Installation Attach the work clamp per the following: 1. Unplug the machine or turn the power switch to the “ OFF ” position.
W ork Cable Installation Refer to Figure A.2. 1. Open the wire feed section door on the right side of the SP-135T. 2. Pass the end of the work cable that has the termi- nal lug with the smaller hole through the Work Cable Access Hole (1) in the case front.
CYLINDER may explode if dam- aged. Keep cylinder upright and chained to support • Keep cylinder away from areas where it may be damaged. • Never lift welder with cylinder attached. • Never allow welding electrode to touch cylinder. • Keep cylinder away from welding or other live electrical circuits.
A-6 INST ALLA TION SP-135T A-6 INPUT CONNECTIONS Refer to Figure A.6. The SP-135T has a power input cable located on the rear of the machine. FIGURE A.6 CODE REQUIREMENTS FOR INPUT CONNECTIONS This welding machine must be connected to a power source in accordance with applicable elec- trical codes.
B-1 OPERA TION B-1 SP-135T Read entire operation section before operating the SP-135T . ELECTRIC SHOCK can kill. • Do not touch electrically live parts or electrode with skin or wet clothing. Insulate yourself from work and ground. • Always wear dry insulating gloves.
B-2 OPERA TION B-2 5. Gun Trigger - Activates welding output, wire feed, and gas solenoid operation. Releasing the trigger deactivates welding and simultaneously activates the “ burnback ” function so that the welding wire does not stick in the weld puddle.
B-3 OPERA TION B-3 FIGURE B.1a FIGURE B.1b WELDING OPERA TIONS SEQUENCE OF OPERA TION Wire Loading Refer to Figures B.2 and B.3. The machine power switch should be turned to the OFF ( “ O ” ) position before working inside the wire feed enclosure.
B-4 OPERA TION B-4 Friction Brake Adjustment With wire spool installed on the spindle shaft and the wing nut loose, turn the spool by hand while slowly tightening the wing nut until a light drag is felt.
B-5 OPERA TION B-5 FIGURE B.6 Making A Weld 1. See “ Process Guidelines ” in this section for selec- tion of welding wire and shielding gas and for range of metal thicknesses that can be welded. 2. See the Application chart on the inside of the wire feed compartment door for information on setting the SP-135T controls.
B-6 OPERA TION B-6 The SP-135T is suitable for .035" aluminum wire and .030" stainless wire. Refer to Table B.1 for recom- mended procedure settings (requires K499 Argon Regulator Kit). TABLE B.1 CHANGING MA CHINE O VER T O FEED O THER WIRE SIZES The SP-135T is shipped from the factory ready to feed .
B-7 LEARNING T O WELD B-7 LEARNING T O WELD No one can learn to weld simply by reading about it. Skill comes only with practice. The following pages will help the inexperienced operator to understand welding and develop this skill. For more detailed infor- mation, order a copy of “ New Lessons in Arc Welding ” listed at the end of this manual.
B-8 LEARNING T O WELD B-8 The “ arc stream ” is seen in the middle of the picture. This is the electric arc created by the electric current flowing through the space between the end of the wire electrode and the base metal. The temperature of this arc is about 6000 ° F, which is more than enough to melt metal.
B-9 LEARNING T O WELD B-9 SP-135T For GMAW (MIG) Process 1. Is most of my welding performed on 16 gauge and lighter materials? 2. Can I afford the extra expense, space, and lack of portability required for gas cylinders and gas sup- ply? 3.
B-10 LEARNING T O WELD B-10 SP-135T FIGURE B.12 Penetration Unless a weld penetrates close to 100% of the metal thickness, a butt weld will be weaker than the material welded together. In the example shown in Figure B.13, the total weld is only half the thickness of the material thus the weld is only approximately half as strong as the metal.
B-11 LEARNING T O WELD B-11 SP-135T FIGURE B.16 Vertical-down Welding Refer to Figure B.17 Vertical-down welds are applied at a fast pace. These welds are therefore shallow and narrow and, as such, are excellent for sheet metal. Vertical-down welds may be applied to 5/32 ” (3.
B-12 LEARNING T O WELD B-12 SP-135T ARC RAYS can burn eyes and skin. When using an open arc process, it Is necessary to use correct eye, head and body protection. Protect yourself and others, read “ ARC RAYS can burn ” at the front of this manual.
B-13 LEARNING T O WELD B-13 SP-135T Helpful Hints 1. For general welding, it is not necessary to weave the arc, neither forward or backward nor sideways.
B-14 LEARNING T O WELD B-14 SP-135T MA CHINE SET UP FOR THE GMA W (MIG) PROCESS 1. See PROCESS GUIDELINES in the OPERATION section for selection of welding wire and shielding gas, and for range of metal thicknesses that can be welded. 2. See the Application Guide on the inside of wire feed section door for information on setting the controls.
B-15 LEARNING T O WELD B-15 SP-135T FIGURE B.24 3. The Correct Electrical Stickout (ESO) The electrical stickout (ESO) is the distance from the end of the contact tip to the end of the wire. See Figure B.24. Once the arc has been established, maintaining the correct ESO becomes extremely important.
B-16 LEARNING T O WELD B-16 TR OUBLESHOO TING WELDS Good welds have excellent appearance. To Eliminate Porosity (in order of importance): 1. Turn on gas supply, if used 2. Decrease voltage. 3. Increase stickout. 4. Increase WFS (wire feed speed). 5. Decrease drag angle.
B-17 LEARNING T O WELD B-17 Proper Gun Handling Most feeding problems are caused by improper han- dling of the gun cable or electrodes. 1. Do not kink or pull the gun around sharp corners 2. Keep the gun cable as straight as practical when welding. 3.
B-18 APPLICA TION CHART B-18 SP-135T.
C-1 A CCESSORIES C-1 OPTIONAL A CCESSORIES 1. K549-1 .035" (0.9 mm) Innershield ® Welding Kit — Includes a contact tip, a gasless nozzle and a .035/.045" (.9/1.2 mm) cable liner to permit the Magnum ™ 100L gun and cable to use .035" (0.
C-2 A CCESSORIES C-2 INNERSHIELD (FCA W) CONVERSION Several changes are needed to convert the unit for operation with the Innershield (FCAW) process. The K549-1 or K549-2 Innershield Kits include all the nec- essary accessories for this conversion and are provid- ed for this purpose.
MAINTENANCE SAFETY PRECA UTIONS ELECTRIC SHOCK can kill. • Disconnect input power by removing plug from receptacle before working inside SP-135T. Use only grounded receptacle. Do not touch electrically “ hot ” parts inside SP-135T. • Have qualified personnel do the mainte- nance and trouble shooting work.
D-2 MAINTENANCE D-2 SP-135T GUN AND CABLE MAINTENANCE FOR MA GNUM ™ 100L GUN Gun Cable Cleaning Clean cable liner after using approximately 300 lbs (136 kg) of solid wire or 50 lbs (23 kg) of flux-cored wire. Remove the cable from the wire feeder and lay it out straight on the floor.
D-3 MAINTENANCE D-3 SP-135T COMPONENT REPLA CEMENT PR OCEDURES CHANGING THE CONT A CT TIP 1. Refer to Figure D.2. Remove the gas nozzle from the gun by unscrewing counter-clockwise. 2. Remove the existing contact tip from the gun by unscrewing counter-clockwise.
GUN HANDLE P ARTS The gun handle consists of two halves that are held together with a collar on each end. To open up the handle, turn the collars approximately 60 degrees counter-clockwise until the collar reaches a stop. Then pull the collar off the gun handle.
E-1 TR OUBLESHOO TING E-1 SP-135T If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2 TR OUBLESHOO TING E-2 SP-135T If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-3 TR OUBLESHOO TING E-3 SP-135T If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-4 TR OUBLESHOO TING E-4 SP-135T If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
F-1 DIA GRAMS F-1 SP-135T S1 SWITCH D1 D3 D2 D4 204 204 204 203 203 203 C1 59,000 f 40V 203 204 - + GUN CABLE CONDUCTOR BLOCK TO WORK ELECTRICAL SYMBOLS PER E1537 CAVITY NUMBERING SEQUENCE ( COMPONENT SIDE OF BOARD ) 539 541 T1 GUN TRIGGER THERMOSTAT 208 5K WIRE SPEED R2 (W) (B) N.
NO TES SP-135T.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
デバイスLincoln Electric IM724の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lincoln Electric IM724をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLincoln Electric IM724の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lincoln Electric IM724の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lincoln Electric IM724で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lincoln Electric IM724を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLincoln Electric IM724の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lincoln Electric IM724に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLincoln Electric IM724デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。