Lincoln ElectricメーカーINVERTEC V160-Sの使用説明書/サービス説明書
ページ先へ移動 of 29
INVER TEC V160-S ™ OPERA TOR’S MANUAL IM737-A August, 2007 Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed a nd built with s afety in mind. Ho wever , y our ov erall safety can be increased by pr oper installatio n ...
FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
iii SAFETY iii FOR ELECTRICALL Y powered equipment. 8.a. T urn off input power using the disconnect switch at the fuse box before working on the equipment. 8 .b . Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer ʼs recommendations.
iv SAFETY iv Mar . ʻ93 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L ʼArc 1.
v v Thank You for selecting a QUALITY product. We want you to take pride in operating this product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference.
vi vi T ABLE OF CONTENTS Page Installation ................................................................................................................... ....Section A T echnical Specifications ....................................................
A-1 INST ALLA TION V160-S A-1 Input Circuit 1 15V (20A Plug and Branch) 1 15V (30A Branch) 230V (30A Branch) 230V (30A Branch) Maximum Open Circuit V oltage 48 V olts Max. Duty Cycle 100% 35% 100% Output Current Range 5-160 Amps INPUT - SINGLE PHASE ONL Y RA TED OUTPUT OUTPUT Height Widt h Depth Weight 12.
A-2 INST ALLA TION V160-S A-2 Read entire installation section before starting installation. SAFETY PRECAUTIONS ELECTRIC SHOCK can kill. • Only qualified personnel should per- form this installation. • Disconnect input power by removing plug from receptacle before working inside V160-S.
A-3 INST ALLA TION V160-S A-3 Fuse the input circuit with time delay fuses marked “D” or delay type 1 circuit breakers. Using fuses or circuit breakers smaller than recommended may result in “nuisance” shut-offs from welder inrush currents even if not welding at high currents.
A-4 INST ALLA TION V160-S A-4 OUTPUT CONNECTIONS ELECTRIC SHOCK can kill. • Keep the electrode holder and cable insulation in good condition. • Do not touch electrically live parts or electrode with skin or wet cloth- ing. • Insulate yourself from work and gr ound.
A-5 INST ALLA TION V160-S A-5 QUICK DISCONNECT PLUG (FOR STICK ELEC- TRODE CABLE) A quick disconnect system is used for the welding cable connections. The stick electrode cable will need to have a plug attached. 1. Cut off welding cable lug, if present.
B-1 OPERA TION V160-S B-1 Read and understand this entire section before operating your machine. SAFETY INSTRUCTIONS ELECTRIC SHOCK can kill. • Do not touch electrically live parts such as output terminals or internal wiring. • Insulate yourself from the work and ground.
B-2 OPERA TION B-2 REAR CONTROL P ANEL 1 . Power Switch: Controls the input power to the machine. Make sure the machine is properly con- nected to the input supply before turning the machine on.(See Figure B.1) 2. F a n : The cooling fan will turn ON when the machine is turned ON and it will continue to run whenever the output of the machine is ON.
B-3 OPERA TION B-3 7. Remote LED: This indicator will turn on when a remote control is connected to the machine via the remote control connector . Using a remote control will change the function of the output current con- trol, refer to the output current control section below .
B-4 OPERA TION B-4 V160-S DIP SWITCH FUNCTIONS T his section has 8 DIP switch functions of the V160- S. Read and understand the functions before making any changes because abnormal operation can occur with the wrong settings. The machine must be turned OFF when the DIP Switches are changed.
B-5 OPERA TION B-5 DIP Switch 6: European/USA Machine Configuration This configures several functions of the V160-S as required by the European and USA markets. For the European market it is OFF and for the USA market it is ON. Specifically , this configures the operation of the TIG slope timers, remote control, and trigger .
C-1 ACCESSORIES C-1 OPTIONAL ACCESSORIES AND COMP A TIBLE EQUIPMENT Factory Installed Electrical Holder and Cable Assembly Work Cable and Clamp Strap Packet Instruction Manual Field Installed K870 - Foot Amptrol tm for TIG welding.
D-1 MAINTENANCE D-1 V160-S SAFETY PRECAUTIONS ELECTRIC SHOCK can kill. • Have an electrician install and serv- ice this equipment. • T urn the input power off at the fuse box, disconnect supply lines and allow machine to sit for five minutes minimum to allow the power capaci- tors to discharge before working inside this equipment.
E-1 TROUBLESHOOTING E-1 V160-S If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2 TROUBLESHOOTING E-2 V160-S Observe all Safety Guidelines detailed throughout this manual PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENTS(S) RECOMMENDED COURSE OF ACTION Excessive spatter Craters Inclusions Insufficient penetration Sticking Porosity Cracks 1.
E-3 TROUBLESHOOTING E-3 V160-S If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-4 TROUBLESHOOTING E-4 V160-S Observe all Safety Guidelines detailed throughout this manual PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION Machine fails to come o.
F-1 DIAGRAMS F-1 V160-S NOTE: This diagram is for refer ence only . It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a r eplacement.
F-2 DIAGRAMS F-2 V160-S NOTE: This diagram is for refer ence only . It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a r eplacement.
NOTES V160-S.
W ARNING AV I S O D E PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING AV I S O D E PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE PARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 441 17-1 199 U.S.A. TEL: 216.481.8100 F AX: 216.486.1751 WEB SITE: www .
デバイスLincoln Electric INVERTEC V160-Sの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lincoln Electric INVERTEC V160-Sをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLincoln Electric INVERTEC V160-Sの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lincoln Electric INVERTEC V160-Sの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lincoln Electric INVERTEC V160-Sで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lincoln Electric INVERTEC V160-Sを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLincoln Electric INVERTEC V160-Sの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lincoln Electric INVERTEC V160-Sに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLincoln Electric INVERTEC V160-Sデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。