Lincoln ElectricメーカーINVERTEC V300-PRO SVM105-Bの使用説明書/サービス説明書
ページ先へ移動 of 117
INVERTEC V300-PRO SVM105-B April, 2007 Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed and built with safety in mind. However , your overall safety can be increased by pr oper installation . . . and thoughtful operation on your part.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC i SAFETY i FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding.
SAFETY iii iii Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FOR ELECTRICALL Y powered equipment. 8.a. T urn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions d.
V300-I v v MASTER T ABLE OF CONTENTS FOR ALL SECTIONS Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i-iv Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC V300-PRO Section A-1 Section A-1 T ABLE OF CONTENTS - INST ALLA TION SECTION - Installation ...........................................................................
V300-PRO Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC A-2 INST ALLA TION A-2 TECHNICAL SPECIFICA TIONS - V300-PRO (K1349-3, K1349-4) Height W idth Depth W eight 18.
V300-PRO INST ALLA TION A-3 A-3 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC THE LINCOLN ELECTRIC CO. CLEVELAND, OHIO U.S.A.
V300-PRO INST ALLA TION A-4 A-4 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC POWER INPUT CONNECTION Connect terminal marked to earth ground per any existing local or national electrical codes.
V300-PRO INST ALLA TION A-5 A-5 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC LN-9 GMA Connection Instructions (Not applicable to machines with only 42V Aux.
V300-PRO INST ALLA TION A-6 A-6 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OUTPUT CABLES Select the output cable size based upon the following chart.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC V300-PRO Section B-1 Section B-1 T ABLE OF CONTENTS - OPERA TION SECTION - Operation ..................................................................................
V300-PRO OPERA TION B-2 B-2 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OPERA TING INSTRUCTIONS DUTY CYCLE The Invertec is rated at 300 amps, 60% duty cycle for 3 phase inputs (based on a 10 minute cycle).
V300-PRO OPERA TION B-3 B-3 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC MODE SWITCH GT A W Optimized for both scratch start and Hi- Freq kit use.
V300-PRO OPERA TION B-4 B-4 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC METER POLARITY SWITCH The wire feeder polarity switch is located at the rear of the machine.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC V300-PRO Section C-1 Section C-1 T ABLE OF CONTENTS - ACCESSORIES SECTION - Accessories ...............................................................................
V300-PRO ACCESSORIES C-2 C-2 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OPTIONS / ACCESSORIES CABLE PLUGS Cable Plug Kit for 1/0-2/0 cable (K852-70) attaches to welding cable to provide quick disconnect from machine.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC V300-PRO Section D-1 Section D-1 T ABLE OF CONTENTS - MAINTENANCE SECTION - Maintenance ...............................................................................
V300-PRO MAINTENANCE D-2 D-2 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC 5. Locate the two capacitor terminals (large hex head capscrews)shown in Figure D.
V300-PRO MAINTENANCE D-3 D-3 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OVERLOAD PROTECTION The machine is electrically protected from producing high output currents.
V300-PRO MAINTENANCE D-4 D-4 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FIGURE D.2 — LOCA TION OF MAINTENANCE COMPONENTS.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC V300-PRO Section E-1 Section E-1 Theory of Operation ...............................................................................................Section E Power Supply Operation .
V300-PRO THEOR Y OF OPERA TION INPUT LINE VOL T AGE & AUXILIAR Y TRANSFORMER The V300-PRO can be connected for a variety of three phase or single phase input voltages. Power is applied through the Line Switch to the Input Rectifier and the Auxiliary T ransformer .
V300-PRO THEOR Y OF OPERA TION PRECHARGE & PROTECTION CIRCUITS The DC voltage from the Input Rectifier is applied to the Driver Board to begin charging the Switch Board capacitors at a slow rate. When the pre-charge level is achieved, the input relays close, applying the full DC voltage to the capacitors.
V300-PRO THEOR Y OF OPERA TION SWITCH BOARDS The Switch Boards contain the the Field Effect T ransistors (FET s) which, when switched ON, supply power to the primary windings of the main transformer . Each Switch Board powers a separate, oppositely wound primary winding.
V300-PRO THEOR Y OF OPERA TION OUTPUT AND CONTROL CIRCUITS The AC output of the transformer is changed to DC by the Output Rectifier . The Output Choke between the negative side of the rectifier and the negative output stud provides the necessary filtering for DC welding.
V300-PRO THEOR Y OF OPERA TION An FET is a type of transistor . FET s are semiconduc- tors well suited for high-frequency switching because they are capable of going from full off to full on much more quicklfy than other types of semi-conductors. Drawing A above shows an FET in a passive mode.
V300-PRO THEOR Y OF OPERA TION E-7 E-7 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Since only 2 microseconds of the 50-microsecond time period is devoted to conducting, the output power is minimized.
V300-PRO THEOR Y OF OPERA TION E-8 E-8 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC THERMAL PROTECTION Thermostats protect the machine from excessive operating temperatures.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC V300-PRO Section F-1 Section F-1 T ABLE OF CONTENTS - TROUBLESHOOTING & REP AIR SECTION - Tr oubleshooting & Repair Section ...................................
HOW TO USE TROUBLESHOOTING GUIDE Service and repair should be performed by only Lincoln Electric Factory T rained Personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician and machine operator and will invalidate your factory warranty .
V300-PRO Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-3 F-3 Sometimes machine failures appear to be due to PC board failures.
V300-PRO TROUBLESHOOTING & REP AIR INPUT FIL TER CAP ACITOR CONDITION- ING Capacitor conditioning may be required if the machine will not produce output after power is applied and the following two conditions exist: The machine is connected to a supply of 380 v .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AI.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-6 F-6 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-7 F-7 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-8 F-8 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-9 F-9 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
V300-PRO NOTES F-10 F-10 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
V300-PRO TROUBLESHOOTING & REP AIR F-11 F-11 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Service and repair should be performed by only Lincoln Electric factory trained personnel.
V300-PRO TROUBLESHOOTING & REP AIR INPUT FIL TER CAP ACITOR DISCHARGE PROCEDURE 1. T urn off input power or disconnect input power lines. 2. Remove 14 5/16” hex head screws from side and top of machine (6 screws on each side and 2 screws on top) and remove wrap-around machine cover .
Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
V300-PRO F-14 F-14 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR TEST PROCEDURE 1. T urn Input Power Switch OFF 2.
V300-PRO F-15 F-15 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR FIGURE F .3 – CONTROL BOARD TEST POINTS OUTPUT PILOT CIRCUIT TEST (cont.
V300-PRO NOTES F-16 F-16 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
V300-PRO TROUBLESHOOTING & REP AIR F-17 F-17 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Service and repair should be performed by only Lincoln Electric factory trained personnel.
V300-PRO TROUBLESHOOTING & REP AIR F-18 F-18 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TEST PROCEDURE 1. TURN POWER SWITCH OFF 2.
V300-PRO TROUBLESHOOTING & REP AIR F-19 F-19 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PROTECTION BOARD OUTPUT TEST(cont.
V300-PRO TROUBLESHOOTING & REP AIR F-20 F-20 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PROTECTION BOARD OUTPUT TEST(cont.
V300-PRO TROUBLESHOOTING & REP AIR F-21 F-21 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Service and repair should be performed by only Lincoln Electric factory trained personnel.
V300-PRO TROUBLESHOOTING & REP AIR F-22 F-22 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ST A TIC CAP ACITOR TEST TEST PROCEDURE: 1.
V300-PRO TROUBLESHOOTING & REP AIR F-23 F-23 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FIGURE F .
V300-PRO NOTES F-24 F-24 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
V300-PRO TROUBLESHOOTING & REP AIR F-25 F-25 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Service and repair should be performed by only Lincoln Electric factory trained personnel.
V300-IPRO TROUBLESHOOTING & REP AIR F-26 F-26 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SWITCH BOARD TEST (cont.) TEST PROCEDURE 1.
V300-PRO TROUBLESHOOTING & REP AIR F-27 F-27 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SWITCH BOARD TEST (CONT .
V300-PRO TROUBLESHOOTING & REP AIR F-28 F-28 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SWITCH BOARD TEST (CONT .
V300-PRO TROUBLESHOOTING & REP AIR F-29 F-29 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Service and repair should be performed by only Lincoln Electric factory trained personnel.
V300-PRO TROUBLESHOOTING & REP AIR 1. T urn main Power off. 2. Perform Input Filter Capacitor Discharge proce- dure. 3. Remove leads 401,402 403 & 404 from theSwitch Boards. 4. T est for 25 ohms resistance from lead 401 to termi- nal 12 on Switch Board.
V300-PRO TROUBLESHOOTING & REP AIR F-31 F-31 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TEST DESCRIPTION This procedur e will determine if the Output Diodes are defective.
V300-PRO TROUBLESHOOTING & REP AIR TEST PROCEDURE 1. Locate the Output T erminals on front panel. 2. Remove any cables from Output T erminals. 3. T est for more than 200 ohms resistance between positive and negative Output T erminals: positive meter lead to the positive terminal, negative meter lead to the negative terminal.
V300-PRO TROUBLESHOOTING & REP AIR TEST DESCRIPTION This procedur e will determine if the Input Rectifier is defective. MA TERIALS NEEDED ANALOG Vo lt/Ohm Meter (multi-meter) Misc.
V300-PRO TROUBLESHOOTING & REP AIR TEST PROCEDURE 1. Pe rform Input Filter Capacitor Discharge Procedure as detailed in this section. 2. Locate Input Rectifier (Component D-13). 3. Locate leads needed to perform tests shown in Figure F .1 1. 4. Use ohmmeter to perform tests shown in T able F .
V300-PRO TROUBLESHOOTING & REP AIR F-35 F-35 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC .
V300-PRO TROUBLESHOOTING & REP AIR TEST PROCEDURE 1. Pe rform Input Filter Capacitor Discharge Procedure detailed in this section. 2. Remove front panel from machine to access Control Board. 3. Arrange wires so there is ample room to work on the board.
V300-PRO TROUBLESHOOTING & REP AIR 6. T urn main power OFF . 7. Pe rform Input Filter Capacitor Discharge Procedure detailed in this section. T est resistance of the Black and White leads from 1J3 and 2J3 to the shunt. See Figure F .14. a. If zero ohms resistance (continuity) is shown, test is OK.
V300-PRO TROUBLESHOOTING & REP AIR F-38 F-38 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC .
V300-PRO TROUBLESHOOTING & REP AIR TEST PROCEDURE 1. T urn main power OFF . 2. Perform Input Filter Capacitor Discharge proce- dure detailed in Maintenance section. 3. Detach the following PC boards so you can gain access to and have ample room to perform the tests: (Do not disconnect from wiring harness.
V300-PRO TROUBLESHOOTING & REP AIR 7. T est for 0 VDC between leads 31 1 and 313 on Protection Board. a. If 0-1 VDC is present, the Protection Board is OK. Go to step 8. b. If 15 VDC is present, go to step 1 1. F-40 F-40 OVER VOL T AGE PROTECTION DC TRIGGER CIRCUIT TEST (cont.
V300-PRO TROUBLESHOOTING & REP AIR 8. T est for 15 VDC supply voltage between leads 302 and 275D on Power Board. a. If 15 VDC is present, test is OK. Go to step 9. b. If 15 VDC is not present, the Power Board may be faulty . Check for 18 V AC input voltage at lead 501 and 504 (J7).
V300-PRO TROUBLESHOOTING & REP AIR 11 . If 15 VDC is present at step 7, test Capacitor volt- ages using leads shown in Figure F .19. If voltage does not match table, check reconnect switches for proper operation and proper position for voltage applied.
V300-PRO TROUBLESHOOTING & REP AIR F-43 F-43 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC .
V300-PRO TROUBLESHOOTING & REP AIR TEST PROCEDURE 1. T urn main power OFF . 2. Perform Input Filter Capacitor Discharge proce- dure detailed in this section. 3. Detach the following PC boards so you can gain access to and have ample room to perform the tests.
V300-PRO TROUBLESHOOTING & REP AIR 4. Locate the Auxiliary T ransformer T1 and leads used for test. See Figure F .21. 5. T urn main power ON. 6. T est Auxiliary T ransformer voltage for 24 V AC between leads 503 and 212D. See Figure F .21. a. If 24 V AC is present, transformer is OK.
V300-PRO NOTES F-46 F-46 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
V300-PRO TROUBLESHOOTING & REP AIR F-47 F-47 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC POWER BOARD TEST W ARNING Service and repair should be performed by only Lincoln Electric factory trained personnel.
V300-PRO TROUBLESHOOTING & REP AIR . TEST PROCEDURE NOTE: Perform T est A before disassembling the unit T est A 1. T urn main power OFF . 2. Position yourself at Switch Board area of the machine (near Case Back) so as to hear the oper- ation of the control relays.
V300-PRO TROUBLESHOOTING & REP AIR 6. T est for 18 V AC input from Auxiliary T ransformer between leads 504 and 501 (J7-pin 5 & pin 6) on Power Board. If 18 V AC is not correct, check the 3 amp fuse, the Auxiliary T ransformer and associated wires.
V300-PRO TROUBLESHOOTING & REP AIR F-50 F-50 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC POWER BOARD TEST (cont.) FIGURE F .
V300-PRO TROUBLESHOOTING & REP AIR F-51 F-51 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC .
V300-PRO TROUBLESHOOTING & REP AIR PROCEDURE NOTE: When replacing capacitors, remove the entire FET Heat Sink Assembly as a unit. Remove and reassemble one side at a time, using the other side as a model to insure that all parts are reinstalled prop erly 1.
V300-PRO TROUBLESHOOTING & REP AIR 4. Remove the two 1/4-28 hex head bolts that hold the Capacitor to the PC board. See Figure F .27. 5. Loosen the set screw of the Capacitor clamp ring and remove the Capacitor from the clamp ring. See Figure F .28.
V300-PRO TROUBLESHOOTING & REP AIR NOTE: Proper capacitor polarity must be noted when attaching the capacitor to the Switch Board assembly . 6. Install the new Capacitor and tighten the two bolts to a torque of 55 inch-pounds (6 Nm). Hand tight- en first, then tighten the bolts in increments of 10 inch-pounds, alternating between the two.
V300-PRO TROUBLESHOOTING & REP AIR F-55 F-55 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC .
V300-PRO TROUBLESHOOTING & REP AIR NOTE: If a test indicates that a Switch Board is defec- tive, unless their part number is L10958-[ ] both Switch Boards must be replaced at the same time.
V300-PRO TROUBLESHOOTING & REP AIR F-57 F-57 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC .
B300-PRO TROUBLESHOOTING & REP AIR TEST PROCEDURE 1. Turn main power OFF . 2. Perform Input Filter Capacitor Dis-charge proce- dure detailed in Mainten-ance section.. 3. Connect a shorting conductor across terminals 14 and 53 of Protection Board. 4.
V300-PRO TROUBLESHOOTING & REP AIR F-59 F-59 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC .
V300-PRO TROUBLESHOOTING & REP AIR PROCEDURE (Paralleled IndividualDiodes) 1. T urn main power OFF . 2. Perform Input Filter Capacitor Discharge proce- dure detailed in Maintenance section.. 3. Detach and remove both Switch Board assemblies and attached capacitors.
V300-PRO TROUBLESHOOTING & REP AIR PROCEDURE (Diode Modules) 1. T urn main power OFF . 2. Perform Input Filter Capacitor Discharge proce- dure detailed in Maintenance section.. 3. Detach and remove both Switch Board assemblies and attached capacitors.
V300-PRO TROUBLESHOOTING & REP AIR F-62 F-62 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC .
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC V300-PRO Section G-1 Section G-1 T ABLE OF CONTENTS - ELECTRICAL DIAGRAMS SECTION - Electrical Diagrams ...............................................................
ELECTRICAL DIAGRAMS G-2 V300 PRO WIRING DIAGRAM - ENTIRE MACHINE - CODE 9825 & 9965 (L8657) G-2 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. The wiring diagram specific to your code is pasted inside one of the enclosure panels of your machine.
ELECTRICAL DIAGRAMS G-3 V300 PRO WIRING DIAGRAM - ENTIRE MACHINE CODE 9934 (L8841) + - ELECTRICAL SYMBOLS PER E1537 { H1 18V T1 FAN MOTOR 75 76 77B GND G F E J A I K C D M L B N H 75 76 77 31 32 41 42 2 4 81 82 21 GND SPARE 42 VAC N.
ELECTRICAL DIAGRAMS G-4 V300 PRO WIRING DIAGRAM - ENTIRE MACHINE CODE 10034 (L9299) G-4 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. The wiring diagram specific to your code is pasted inside one of the enclosure panels of your machine.
ELECTRICAL DIAGRAMS G-5 V300 PRO WIRING DIAGRAM - ENTIRE MACHINE CODE 10035 (L9301) G-5 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. The wiring diagram specific to your code is pasted inside one of the enclosure panels of your machine.
ELECTRICAL DIAGRAMS G-6 V300 PRO WIRING DIAGRAM - ENTIRE MACHINE CODE 10130 (L9567) G-6 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. The wiring diagram specific to your code is pasted inside one of the enclosure panels of your machine.
ELECTRICAL DIAGRAMS G-7 V300 PRO WIRING DIAGRAM - ENTIRE MACHINE CODE 10131 (L9569) G-7 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. The wiring diagram specific to your code is pasted inside one of the enclosure panels of your machine.
ELECTRICAL DIAGRAMS G-8 V300 PRO WIRING DIAGRAM - ENTIRE MACHINE CODE 10256 (L10189) G-8 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. The wiring diagram specific to your code is pasted inside one of the enclosure panels of your machine.
ELECTRICAL DIAGRAMS G-9 V300 PRO WIRING DIAGRAM - ENTIRE MACHINE - CODE 10257 (L10191) G-9 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. The wiring diagram specific to your code is pasted inside one of the enclosure panels of your machine.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRICAL DIAGRAMS G-10 V300 PRO SCHEMA TIC - ENTIRE MACHINE G-10 NOTE: This diagram is for reference only .
ELECTRICAL DIAGRAMS G-11 V300 PRO SCHEMA TIC - DRIVER PC BOARD - (S20216) G-11 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual.
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric.
ELECTRICAL DIAGRAMS G-13 V300 PRO SCHEMA TIC - DRIVER PC BOARD (S20799) G-13 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual.
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric.
ELECTRICAL DIAGRAMS G-15 V300 PRO SCHEMA TIC - SWITCH PC BOARD (L8440) G-15 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual.
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric.
ELECTRICAL DIAGRAMS G-17 V300 PRO SCHEMA TIC - SWITCH PC BOARD (L10956) G-17 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual.
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric.
ELECTRICAL DIAGRAMS G-19 V300 PRO SCHEMA TIC - CONTROL PC BOARD (G2525) G-19 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual.
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric.
ELECTRICAL DIAGRAMS G-21 V300 PRO G-21 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. The wiring diagram specific to your code is pasted inside one of the enclosure panels of your machine.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRICAL DIAGRAMS G-22 V300 PRO SCHEMA TIC - PROTECTION PC BOARD (M16097) G-22 NOTE: This diagram is for reference only .
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric.
ELECTRICAL DIAGRAMS G-24 V300 PRO SCHEMA TIC - POWER PC BOARD (M16018) G-24 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual.
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty . Individual Printed Circuit Board Components are not available from Lincoln Electric.
デバイスLincoln Electric INVERTEC V300-PRO SVM105-Bの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lincoln Electric INVERTEC V300-PRO SVM105-Bをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLincoln Electric INVERTEC V300-PRO SVM105-Bの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lincoln Electric INVERTEC V300-PRO SVM105-Bの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lincoln Electric INVERTEC V300-PRO SVM105-Bで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lincoln Electric INVERTEC V300-PRO SVM105-Bを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLincoln Electric INVERTEC V300-PRO SVM105-Bの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lincoln Electric INVERTEC V300-PRO SVM105-Bに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLincoln Electric INVERTEC V300-PRO SVM105-Bデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。