Lincoln ElectricメーカーRED-D-ARC E500の使用説明書/サービス説明書
ページ先へ移動 of 28
RED-D-ARC E500 IM656-A April, 2004 Red-D-Ar c Spec-Built W elding Equipment This RED-D-ARC welder is built to RED-D-ARC Extreme Duty design specifications by Lincoln Electric. Safety Depends on Y ou This welder is designed and built with safety in mind.
i SAFETY i FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
iii SAFETY iii E500 FOR ELECTRICALL Y powered equipment. 8.a. T urn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer ’s recommendations.
iv SAFETY iv E500 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L ’Arc 1.
E500 T hank Y ou for selecting this QUALITY product. We want you to take pride in operating this product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
E500 vi T ABLE OF CONTENTS vi Page Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Secti on A Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A-1 INST ALLA TION A-1 LOCA TION F ALLING EQUIPMENT can cause injury . • Do not lift this machine using lift bail if it is equipped with a heavy • accessory such as trailer or gas cylinder . • Lift only with equipment of adequate lifting capacity .
B-1 OPERA TION B-1 ELECTRIC SHOCK can kill. • Do not touch electrically live parts or electrode with skin or wet cloth- ing. • Insulate yourself from work and ground. • Always wear dry insulating gloves. FUMES AND GASES can be danger- ous. • Keep your head out of fumes.
C-1 MAINTENANCE C-1 ELECTRIC SHOCK can kill. • Have an electrician install and ser- vice this equipment. • T urn the input power off at the fuse box before working on equipment. • Do not touch electrically hot parts. GENERAL MAINTENANCE 1. The fan motor has sealed bearings which require no service.
E500 D-1 TROUBLESHOOTING D-1 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
D-2 TROUBLESHOOTING D-2 Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
D-3 TROUBLESHOOTING D-3 Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
D-4 TROUBLESHOOTING D-4 Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
D-5 TROUBLESHOOTING D-5 Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
D-6 TROUBLESHOOTING D-6 Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
D-7 TROUBLESHOOTING D-7 E500 Low output, low OCV , or erratic welding T urn control pot. to minimum Check OCV OCV is 35-55V OCV is 40-45V OCV is 0 Rated OCV but OCV less than rated erratic welding but.
D-8 TROUBLESHOOTING D-8 TROUBLESHOOTING PROCEDURES PROCEDURE FOR REPLACING P .C. BOARD (The P .C. Board is located behind the front control panel. Remove the nameplate screws to loosen the control panel.) When the P .C. Board is to be replaced, follow this pro- cedure: Visually inspect P .
D-9 TROUBLESHOOTING D-9 Check the resistance reading between 75 on the ter- minal strip and 21 1 on SW #2. The reading must be 10K ohms. No reading will indicate an open rheostat and a low reading will indicate a shorted or partially shorted rheostat; in either case, replace.
D-10 TROUBLESHOOTING D-10 5. An open gate circuit will have an infinite or high resistance. A good gate circuit will read a low resis- tance, but not zero ohms. BA TTER Y TEST Check the batteries by shorting leads (A) and (C), then close switch SW-1. Replace batteries if voltage is less than 3 volts.
E-1 WIRING DIAGRAM - CODE 10649 ONL Y E-1 E500 ELECTRICAL SYMBOLS PER E1537 LEGEND D5 D6 D7 POCKET AMPTROL SENSING BRIDGE L1 DC OUTPUT FILTER R1 R2 R3 R4 TO GROUND PER NATIONAL ELECTRICAL CODE H3 H2 H.
E500 E-2 WIRING DIAGRAM - CODE 1 1042 & UP E-2 ELECTRICAL SYMBOLS PER E1537 LEGEND L1 DC OUTPUT FILTER R1 R2 R3 TO GROUND PER NATIONAL ELECTRICAL CODE H3 H2 H1 X2 X1 T2 TO SUPPLY LINES DIAL SELECT.
E500 E-3 DIAGRAMS E-3 Part No. T ype A B C D F G H M12244-7 E500 32.00 15.39 3092 1.44 30.02± .1 1 33.07± .06 .94 M12244-7 7-7-78.
E500 NOTES.
E500 NOTES.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE PARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 441 17-1 199 U.S.A. TEL: 216.481.8100 F AX: 216.486.1751 WEB SITE: www .
デバイスLincoln Electric RED-D-ARC E500の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lincoln Electric RED-D-ARC E500をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLincoln Electric RED-D-ARC E500の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lincoln Electric RED-D-ARC E500の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lincoln Electric RED-D-ARC E500で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lincoln Electric RED-D-ARC E500を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLincoln Electric RED-D-ARC E500の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lincoln Electric RED-D-ARC E500に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLincoln Electric RED-D-ARC E500デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。