Lincoln ElectricメーカーS22693-121の使用説明書/サービス説明書
ページ先へ移動 of 25
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
iv SAFETY iv Mar. ‘93 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1.
Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
vi vi T ABLE OF CONTENTS Page Installation………………………………………………………………...……...…….Section A Technical Specifications ...................................................................................
A-1 INST ALLA TION A-1 800 AMP TANDEM MIG TORCH T orch and Cable assembly weights Torch body: 6.8 lbs (cables elevated 1 ft above torch body, 4ft from torch body) Shielding Gas Flow Rate W ater Coolin.
800 AMP TANDEM MIG TORCH GENERAL DESCRIPTION The Tandem MIG 800 Amp Welding Torch is designed to deliver two wire electrodes to a single weld pool. The wire electrodes are electrically isolated from one another providing independent parameter control of both electrodes.
800 AMP TANDEM MIG TORCH CONT ACT TIP AND DIFFUSER INST ALLA TION The welding torch is equipped with specially designed diffusers. The diffuser is of a low profile design to accommodate the Tandem torch design. The diffuser is required to provide a current path to the contact tip and must be secured tightly.
800 AMP TANDEM MIG TORCH CONT ACT TIP SIZE Contact tips are available in standard sizes to match the wire specifications of the welding torch (.035, .045, .
B-1 OPERA TION B-1 ELECTRODES AND EQUIPMENT The Tandem MIG 800 amp torch has been designed for use with 0.035" through 0.062" diameter Lincoln Electric solid and metal cored steel GMAW wire weld- ing electrodes.
B-2 OPERA TION B-2 NOZZLE REAMING ST A TIONS During robotic applications a reamer should be employed to keep the nozzle clean. Reaming the noz- zle between welds will reduce the down time associat- ed with manual torch cleaning. The M18426-1 ream- ing station is an option that is recommended for noz- zle cleaning.
C-1 MAINTENANCE C-1 CONT ACT TIP REPLACEMENT Each application will dictate the frequency of contact tip replacement. Higher amperage, higher duty cycle operations will require more frequent contact tip replacement. The condition of the contact tip greatly effects the welding performance of the Tandem MIG process.
C-2 MAINTENANCE C-2 CONT ACT TIP ALIGNMENT During gooseneck replacement or after a torch colli- sion it may be required to check the contact tip align- ment. If using a robot, it is recommended that a tool center pointer is placed in the robotic cell to define the location of the lead wire.
C-3 MAINTENANCE C-3 800 AMP TANDEM MIG TORCH S22693-XXX MIG 800 amp Torch All dimensions in inches. Brackete d dimensions are in [milli meters].
C-4 MAINTENANCE C-4 800 AMP TANDEM MIG TORCH L10430-1 Torch Alignment Tool (Consisting of the following three parts) 1. Base dimensions (Part number L10430-3) 2.
C-5 MAINTENANCE C-5 800 AMP TANDEM MIG TORCH L10430-1 Torch Alignment Tool 3. Holding block dimensions (Part number L10430-4).
D-1 TROUBLESHOOTING D-1 800 AMP TANDEM MIG TORCH If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
D-2 TROUBLESHOOTING D-2 800 AMP TANDEM MIG TORCH Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
NOTES 800 AMP TANDEM MIG TORCH.
NOTES 800 AMP TANDEM MIG TORCH.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE PARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
デバイスLincoln Electric S22693-121の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lincoln Electric S22693-121をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLincoln Electric S22693-121の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lincoln Electric S22693-121の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lincoln Electric S22693-121で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lincoln Electric S22693-121を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLincoln Electric S22693-121の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lincoln Electric S22693-121に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLincoln Electric S22693-121デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。