SVM127-A November , 1996 Safety Depends on Y ou Lincoln arc welding equipment is designed and built with safety in mind. However , your overall safety can be increased by proper installation.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SAFETY i i LN-9 Wire Feeder FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SAFETY ii ii LN-9 Wire Feeder ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SAFETY iii iii LN-9 Wire Feeder FOR ELECTRICALL Y powered equipment. 8.a. T urn off input power using the disconnect switch at the fuse box before working on the equipment.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SAFETY iv iv LN-9 Wire Feeder PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les inst.
MASTER T ABLE OF CONTENTS FOR ALL SECTIONS v v LN-9 Wire Feeder Page Safety .................................................................................................................................................i-iv Installation ............
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T ABLE OF CONTENTS - INST ALLA TION SECTION - Section A-1 Section A-1 LN-9 Wire Feeder Installation ...................................................................
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INST ALLA TION A-2 A-2 TECHNICAL SPECIFICA TIONS — LN-9 INPUT POWER Supplied by power source: 1 15 V AC, 50/60 Hz.
INST ALLING THE LN-9N and LN-9S 2-ROLL AND 4-ROLL MODELS A TT ACHING THE WIRE REEL ST AND Both 2-Roll and 4-Roll LN-9 model wire feeders are shipped without a wire reel stand. The screws and washers for mounting a wire reel stand are included with the LN-9 (fastened in their respective mounting holes).
ROUTING THE ELECTRODE The electrode supply may be either from reels, Readi- Reels, spools, or bulk packaged drums or reels. Observe the following precautions: • The electrode must be routed to the wire feed unit so that the bends in the wire are at a minimum.
CONNECTING THE POWER INPUT CABLE ASSEMBL Y TO THE LN-9NE or LN-9SE The hand crank drive rolls will feed all the wires used on the extension. The rolls have been stenciled for identification. 1. Position the extension assembly cable so that the amphenol plug with the threads on its O.
7. If using welding currents over 450 amperes, con- nect a length of 1/0 cable between the brass block on the hand crank and the input strap located in the wire drive unit. T ape this cable to the extension assembly . Proper cable lengths are as follows: 22-1/2 ft.
CONNECTING THE POWER INPUT CABLE ASSEMBL Y TO POWER SOURCES T urn input supply power to the power source OFF before connecting the LN-9 or LN-9F wire feeder .
INST ALLA TION A-8 A-8 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FIGURE A.5 – CONNECTION OF LN-9 TO DC-250, DC-400, AND CV/CVI POWER SOURCES Above diagram shows electrode connected positive.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INST ALLA TION A-9 A-9 LN-9 Wire Feeder FIGURE A.6 – CONNECTION OF LN-9 TO DC-600 POWER SOURCES Above diagram shows electrode connected positive.
INST ALLA TION A-10 A-10 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FIGURE A.7 – CONNECTION OF LN-9 TO DC-1000 POWER SOURCES Above diagram shows electrode connected positive.
INST ALLA TION A-11 A-11 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FIGURE A.8 – CONNECTION OF LN-9 TO PULSE POWER 500 POWER SOURCES Above diagram shows electrode connected positive.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INST ALLA TION A-12 A-12 LN-9 Wire Feeder MACHINE GROUNDING LN-9 wire feeders are grounded to the power source through the input cable.
CONNECTING THE GUN CABLE T O THE WIRE FEEDER A variety of gun and cable assemblies are available for the LN-9 models. See the Accessories section of this manual. Lay the cable out straight. Insert the connector on the welding conductor cable into the brass conductor block on the front of the wire drive unit.
NOTES A-14 A-14 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section B-1 Section B-1 LN-9 Wire Feeder T ABLE OF CONTENTS - OPERA TION SECTION - Operation ..........................................................................
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC B-2 B-2 LN-9 Wire Feeder SAFETY INSTRUCTIONS Read and understand this entire section of operating instructions operating the machine.
GENERAL DESCRIPTION The LN-9 2-Roll and 4-Roll semiautomatic wire feeder models feature the precise "set and forget" digital pro- cedure control.
CONTROLS AND SETTINGS Operator controls for LN-9N, NE, S and SE models are shown in Figure B.1. Controls for LN-9F models are shown in Figure B.2. Refer to these figures and the fol- lowing descriptions of the controls.
FIGURE B.1 – WIRE FEEDER CONTROLS FOR LN-9N, NE, S, SE OPERA TION B-5 B-5 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TO.
OPERA TION B-6 B-6 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FIGURE B.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OPERA TION B-7 B-7 LN-9 Wire.
If such a grounding lead fault occurs, the meter will still be on and will be reading. The trigger circuit will not operate, however . T o release the circuit, press the "GLP Reset" button. See Figure B.1 or B.2 for the location of this button.
DRIVE ROLL INST ALLA TION AND PRESSURE SETTING CHANGING WIRE FEED ROLLS AND GUIDE TUBES FOR TWO-ROLL WIRE FEEDERS T o change drive or idle rolls on a two-roll wire feeder , refer to Figure B.3 and perform the following steps: 1. Loosen idle roll spring pressure screw .
6. Loosen the ingoing guide tube clamping screw . Install the all steel guide tube through the rear brass block. T ighten the locking screw . 7. Replace the large ingoing guide tube into rear brass block. 8. Install the outgoing guide tube with its plastic insert through front brass block.
CHANGING WIRE FEED ROLLS AND GUIDE TUBES FOR 4-ROLL WIRE FEED- ERS T o change drive rolls on a 4-roll wire feeder , refer to Figure B.4 and perform the following steps: 1. Release both quick release levers. 2. Remove clamping collars from both drive shafts.
For Aluminum Wire Each set of rolls should have their pressure set independent of the other . T o do this, release and open the other quick release arm while making each adjustment. Follow the procedure below for each adjustment. 1. With low idle roll pressure, load the feeder so it’s ready for welding.
OPERA TION B-13 B-13 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FIGURE B.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OPERA TION B-14 B-14 LN-9 Wire Feeder WIRE LOADING LOADING AND FEEDING READI-REELS OR SPOOLS LOADING A 22 TO 30 LB.
7. T o remove the Readi-Reel from the adapter , depress the retaining spring tab with thumb while pulling the Readi-Reel cage from the molded adapter with both hands. Do not remove the adapter from the spindle. LOADING A 15 TO 30 LB. SPOOL (12" DIAMETER): (For 8" spools, a K468 spindle adapter must be used.
LOADING 50 AND 60 LB. COILS AND BRAKE ADJUSTMENT (K299 or K303 Wire Reel Stand) 1. T o remove the wire reel from its shaft, grasp the spring loaded knob and pull it out. This straightens the knob so that it seats into the shaft when released. Remove the reel.
ELECTRODE FEEDING 1. T urn the reel until the free end of the electrode is accessible. 2. While tightly holding the electrode, cut off the bent end. Straighten the first 6 inches. 3. Cut off the first inch. Insert the free end through the incoming guide tube.
MAKING A TEST WELD AND ADJUSTING LN-9 RESPONSE AND ST ARTING CHARACTERISTICS ADJUST THE POWER SOURCE DC-250, DC-400, or DC-600* 1. Connect electrode lead to terminal of desired polarity . 2. Set toggle switch to same polarity as the electrode cable connection.
ADJUST THE LN-9 CONTROLS 1. Set the "Electrode Polarity" switch to same polarity as the electrode lead. 2. Connect the "Direct Work Lead" if it is going to be used. 3. Check that "Feed Direction" is set to forward. 4. Set the "T rigger Interlock" switch as desired.
MAKING A WELD 1. Inch the electrode through the gun and cable and then cut the electrode within approximately 3/8" of the end of the contact tip for solid wire and within approximately 3/4" of the extension guide for cored wire. 2. Connect the work cable to the metal to be welded.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T ABLE OF CONTENTS - ACCESSORIES - Accessories ........................................................................................................................
AUXILIAR Y EQUIPMENT CONT ACTS The power for 1 15 volt AC auxiliary equipment can be obtained from the terminals inside the LN-9 control box. The contacts are “hot” whenever the trigger is pressed or the unit is welding. The current draw of this circuit must not exceed 1/4 ampere.
A TT ACHING THE WIRE REEL ST ANDS The mounting hardware for mounting the stands is included with the LN-9. Screws and washers are inserted in their respective mounting holes. T o con- nect: 1. Remove the three 3/8 in. hex head bolts from the back of the wire feed unit.
ACCESSORIES C-4 C-4 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC GUN AND CABLE ASSEMBLIES A variety of standard Lincoln and Magnum gun and cable assemblies are available for the LN-9 in 10 ft.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ACCESSORIES C-5 C-5 LN-9 Wire Feeder WIRE FEEDER ACCESSORIES BURNBACK DELA Y KIT (K202) Provides a precise control of the electrode burnback at the end of the weld.
SWIVEL PLA TFORM (K178-1) For all LN-9 wire reel stand combinations. For mount- ing wire feeder-wire reel stand assembly on top of suit- able Lincoln Idealarc power sources. Recommended input cable assembly length is 10 feet (3m) when using the K178-1.
ACCESSORIES C-7 C-7 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Ma.
ACCESSORIES C-8 C-8 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T ABLE C.2 – DRIVE ROLL AND GUIDE TUBE KITS Wire Size Kit 2-Roll 4-Roll Solid Steel Electrode .
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section D-1 Section D-1 LN-9 Wire Feeder T ABLE OF CONTENTS -MAINTENANCE- Maintenance .................................................................................
SAFETY PRECAUTIONS ELECTRIC SHOCK can kill. • Only qualified personnel should perform this maintenance. • T urn the input supply power OFF at the disconnect switch or fuse box before working on this equipment. • Do not touch electrically hot parts.
GUN AND CABLE MAINTENANCE For instructions on periodic maintenance for the weld- ing gun and cables, refer to the manual for your specif- ic model of welding gun. Also see IM-294. GUN CABLE CONNECTOR REQUIREMENTS TO PERMIT PROPER CONNECTION TO LINCOLN LN-9 AND LN-9F WIRE FEEDER The following Figures D.
MAINTENANCE D-4 D-4 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FIGURE D.3 – GENERAL COMPONENT LOCA TIONS 1.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section E-1 Section E-1 LN-9 Wire Feeder Theory of Operation ..........................................................................................................
POWER INPUT CIRCUITS The 1 15V AC is applied (usually from the welding power source) via the input connector and through the circuit breaker and R1 resistor to the power board, the T2 trig- ger transformer , and the T1 transformer . The 24V AC developed at the T2 trigger transformer is applied to the trigger board.
TRIGGER AND SHUTDOWN CIRCUIT When the gun trigger switch is activated (closed), the trigger board completes the trigger signal path. This energizes the CR1 relay located on the power board. The CR1 relay activates the wire drive motor and the #2 and #4 circuit, which then activates the Lincoln welding power source.
ARC VOL T AGE, WIRE SPEED CONTROL AND METERING The arc voltage, which is sensed at the work piece and motor gear box, is connected through a polarity switch to the voltage board. This actual arc voltage is com- pared to the reference preset voltage that is set by the voltage control.
PRINTED CIRCUIT BOARD FUNCTIONS POWER BOARD The input power (1 15V AC) is applied to the power board, and from that the power board develops the DC field voltage for the wire drive motor . The SCR circuit- ry , used to control the motor armature voltage, is also contained on the power board.
NOTES E-6 E-6 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master T.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section F-1 Section F-1 LN-9 Wire Feeder T roubleshooting & Repair Section ................................................................................ Section F How to Use T roubleshooting Guide .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC HOW T O USE TROUBLESHOOTING GUIDE Service and repair should be performed by only Lincoln Electric Factory Trained Personnel.
ELECTRIC SHOCK can kill. Have an electrician install and service this equipment. T urn the machine OFF before working on equipment. Do not touch electrically hot parts. Sometimes machine failures appear to be due to PC board failures. These problems can sometimes be traced to poor electrical connections.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-4 F-4 LN-9 Wire Feeder Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-5 F-5 LN-9 Wire Feeder TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-6 F-6 LN-9 Wire Feeder Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-7 F-7 LN-9 Wire Feeder TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-8 F-8 LN-9 Wire Feeder Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-9 F-9 LN-9 Wire Feeder TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-10 F-10 LN-9 Wire Feeder Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-11 F-11 LN-9 Wire Feeder TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-12 F-12 LN-9 Wire Feeder TROUBLESHOOTING & REP AIR TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-13 F-13 LN-9 Wire Feeder Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual.
TROUBLESHOOTING & REP AIR F-14 F-14 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-15 F-15 LN-9 Wire Feeder TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
TROUBLESHOOTING & REP AIR F-16 F-16 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
TROUBLESHOOTING & REP AIR F-17 F-17 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
TROUBLESHOOTING & REP AIR F-18 F-18 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
TROUBLESHOOTING & REP AIR F-19 F-19 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
TROUBLESHOOTING & REP AIR F-20 F-20 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
TROUBLESHOOTING & REP AIR F-21 F-21 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
TROUBLESHOOTING & REP AIR F-22 F-22 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-23 F-23 LN-9 Wire Feeder T1 TRANSFORMER TEST W ARNING Service and repair should be performed by only Lincoln Electric factory trained personnel.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-24 F-24 LN-9 Wire Feeder T1 TRANSFORMER TEST (continued) TEST PROCEDURE 1.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-25 F-25 LN-9 Wire Feeder 6. Using the volt/ohmmeter , check for 10V AC at secondary leads #601 and #602.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-26 F-26 LN-9 Wire Feeder W ARNING T2 TRANSFORMER TEST Service and repair should be performed by only Lincoln Electric factory trained personnel.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-27 F-27 LN-9 Wire Feeder T2 TRANSFORMER TEST (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-28 F-28 LN-9 Wire Feeder T2 TRANSFORMER TEST (continued) 4.
TROUBLESHOOTING & REP AIR F-29 F-29 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T2 TRANSFORMER TEST (continued) Electric Shock can kill.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AI.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-31 F-31 LN-9 Wire Feeder WIRE DRIVE MOT OR AND T ACH FEEDBACK TEST (continued) FIGURE F .
6. Apply 1 15 V AC power . ELECTRIC SHOCK can kill. • With power applied, there are high voltages inside the wire feeder . Do not reach into the wire feeder or touch any internal part of the wire feeder while power is applied.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-33 F-33 LN-9 Wire Feeder T ACH FEEDBACK TEST PROCEDURE 1.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AI.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-35 F-35 LN-9 Wire Feeder VOL TMETER ACCURACY TEST (continued) FIGURE F .
ELECTRIC SHOCK can kill. • With power applied, there are high voltages inside the wire feeder . Do not reach into the wire feeder or touch any internal part of the wire feeder while power is applied.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AI.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-38 F-38 LN-9 Wire Feeder METER CIRCUIT ACCURACY TEST (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-39 F-39 LN-9 Wire Feeder METER CIRCUIT ACCURACY TEST (continued) 5.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-40 F-40 LN-9 Wire Feeder METER CIRCUIT ACCURACY TEST (continued) T est Digital Meter Accuracy .
T est Meter PC Board Accuracy . (Metric Models Only) 1. Use a test meter with at least 3-1/2 digits and +/- .5% accuracy . 2. Connect the + probe to lead called for in the table below and the - probe to lead #510C. NOTE: The coating will have to be removed from the test points.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AI.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AI.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AI.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-45 F-45 LN-9 Wire Feeder OUT OF VOL T AGE RANGE SHUT DOWN TEST (continued) FIGURE F .
TROUBLESHOOTING & REP AIR F-46 F-46 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OUT OF VOL T AGE RANGE SHUT DOWN TEST (continued) 8.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AI.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-48 F-48 LN-9 Wire Feeder GENERAL POWER SUPPL Y TESTS (continued) TEST PROCEDURE 1.
TROUBLESHOOTING & REP AIR F-49 F-49 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC GENERAL POWER SUPPL Y CHECKS CHECKPOINT TEST CONNECTOR LEAD NO.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AI.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-51 F-51 LN-9 Wire Feeder FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-52 F-52 LN-9 Wire Feeder FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AI.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-54 F-54 LN-9 Wire Feeder PROCEDURE 1. Remove input power to the LN-9 wire feeder .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AI.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-56 F-56 LN-9 Wire Feeder PROCEDURE 1. Remove input power to the LN-9.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-57 F-57 LN-9 Wire Feeder 6. Disconnect leads #526 and #527 from the power PC board terminals.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-58 F-58 LN-9 Wire Feeder 8. Remove the two phillips head screws from the control PC board mounting panel.
TROUBLESHOOTING & REP AIR F-59 F-59 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T1 TRANSFORMER REMOV AL AND REPLACEMENT (continued) 1 1.
F-60 F-60 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T.
TROUBLESHOOTING & REP AIR F-61 F-61 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PROCEDURE 1. Remove input power to the LN-9 wire feeder .
F-62 F-62 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR 5. Remove control PC board leads #510, #525 and #555.
F-63 F-63 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR T ACH PC BOARD REMOV AL AND REPLACEMENT (continued) REASSEMBL Y 8.
F-64 F-64 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T.
F-65 F-65 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR DRIVE MOT OR REMOV AL AND REPLACEMENT (continued) PROCEDURE 1.
F-66 F-66 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR DRIVE MOT OR REMOV AL AND REPLACEMENT (continued) 1 1.
TROUBLESHOOTING & REP AIR F-67 F-67 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC 13.
F-68 F-68 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR DRIVE MOT OR REMOV AL AND REPLACEMENT (continued) 15.
TROUBLESHOOTING & REP AIR F-69 F-69 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Mas.
NOTES F-70 F-70 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master.
ELECTRICAL DIAGRAMS G-1 G-1 LN-9 Wire Feeder Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Electrical Diagram Section ............................................................................................ Section G Wiring Diagram .
NOTES LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
G-2 ELECTRICAL DIAGRAMS LN-9 Wiring Diagram 517 510 518 562 518 C2 516 1 2 3 4 5 6 7 8 9 10 11 12 513 C3 VOLTS-SPEED SELECTOR SWITCH 561 560 517 1 4 3 6 2 5 7 8 9 562 561 560 517 510 518 510C 602 601 METER BOARD DIGITAL METER METER BOARD PLUG 562 561 560 517 517 510 518 518 87 6 53 4 1 2 9 510B 510A 602 601 N.
G-3 ELECTRICAL DIAGRAMS LN-9 OPERA TING SCHEMA TIC 1702 3-25-94A 8-2-96B OPERATING SCHEMATIC FI NONE 1702 6-14-85 11-1-96 G1590 t UNLESS OTHERWISE SPECIFIED TOLERANCE ON HOLE SIZES PER E2056 ON 2 PLACE DECIMALS IS .02 WITH PUBLISHED STANDARDS. ON 3 PLACE DECIMALS IS .
G-4 ELECTRICAL DIAGRAMS LN-9 METER BOARD (L6687) SCHEMA TIC (UNLESS OTHERWISE SPECIFIED) EC +5V 602 TP5 METER BOARD SCHEMATIC 21145 LN-9 & LN-9F (METRIC) SUBJECT S SHT. SUP'S'D'G. COMMON CONNECTION EQUIP. TYPE NO. EARTH GROUND CONNECTION POWER SUPPLY SOURCE POINT FRAME CONNECTION CHK.
G-5 ELECTRICAL DIAGRAMS LN-9 TRIGGER BOARD (M13861) SCHEMA TIC 1A 600V D5 1A 600V D6 OCI1 4 3 OCI1 1 2 562 R5 1A 600V D2 1A 600V D3 332 R1 1A 600V D4 1A 600V D1 50 25V C1 1W 20V DZ1 1W 75V DZ2 332 R3 562 R4 562 R6 562 R2 500 S 530 622 20031 24 VAC SWITCH 621 TRIGGER 620 623 FILE: S20031_3EB LABELS ELECTRICAL SYMBOLS PER E1537 A PRINTED N.
G-6 ELECTRICAL DIAGRAMS LN-9 T ACHOMETER SCHEMA TIC 525 15.0K R2 1.3K R4 40V 600mA Q1 OCI1 2 3 1 4 1/4W ( UNLESS OTHERWISE SPECIFIED) 1A, 400V RESISTORS = Ohms ( LN-9 TACHOMETER LABELS FRAME CONNECTION SUPPLY POWER SUPPLY SOURCE POINT EQUIP. TYPE THE LINCOLN ELECTRIC CO.
デバイスLincoln Electric SVM127-Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lincoln Electric SVM127-Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLincoln Electric SVM127-Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lincoln Electric SVM127-Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lincoln Electric SVM127-Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lincoln Electric SVM127-Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLincoln Electric SVM127-Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lincoln Electric SVM127-Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLincoln Electric SVM127-Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。