RE-1 Residential T elephone Entr y System With Built-in Wireless Receiv er (760) 438-7000 USA & Canada (800) 421-1587 & (800) 392-0123 Toll Free FAX (800) 468-1340 www.linearcorp.com Installation, Progr amming, and Oper ation Instructions PRINTER’S INSTRUCTIONS: INSTR,INSTL,RE-1 - LINEAR P/N: 217490 C - INK: BLACK - MA TERIAL: 20 LB.
CONTENTS FEA TURES • TWO-WA Y SPEAKERPHONE • CALL W AITING • CALL FORWARDING • DISTINCTIVE RINGS FOR ACCESS CALLS • SEVEN ACCESS TIME ZONES • TIMED “DO NOT DISTURB” PRIV ACY FEA TURE .
1 PRODUCT DESCRIPTION Linear’ s RE-1 T elephone Entry System is designed for residential or light commercial access control applications. The speakerphone, ke ypad, radio receiver , and optional video camera are housed in a rugged enclosure that can be mounted to a pedestal or bolted directly to a wall.
2 INST ALLA TION INFORMA TION Before beginning installation, please re view the entire instructions and become familiar with the system’ s operation, wiring, and programmab le options. System Location For pedestrian door or gate installations, mount the Entry System on a rigid wall near the controlled door .
3 12 RELA Y TERMINAL BLOCK For Rela y #1 and Relay #2 output connections to the access control devices . 13 RELA Y INDICA TORS Indicators for Rela y #1 and Relay #2 will light when the rela y is activated. 14 ANTENNA TERMINAL BLOCK For shield and center conductor connection of the coax cab le from the system’ s built-in r adio antenna.
4 WIRING DIAGRAM GATE OPERATOR OPEN 16 VAC 20 VA TRANSFORMER TELCO OPEN #1 KEYPAD GND KEYPAD DAT 1 KEYPAD DAT 0 KEYPAD PWR TRAN S FORMER TRAN S FORMER BATTERY NEGATIVE BATTERY PO S ITIVE S EN S E #1 COMMON KEYPAD CLK KEYPAD DVAL OPEN #2 RELAY #1 RE-1 TELEPHONE ENTRY SYSTEM S EN S E #2 TYPICAL GATE INSTALLATION WIRING GROUND STAKE N.
5 ENTRY SYSTEM MOUNTING Pedestal Mounting The RE-1 Entry System can be mounted on a standard pedestal. 1. Open the RE-1 case by removing the tw o security screws with the wrench provided (see Figure 2). 2. Use four security bolts and locking n uts to secure the backplate to the pedestal (see Figure 3).
6 TELEPHONE WIRING OPTIONS Shared Line This is the standard confi guration. The telephone line is routed through the RE-1 to the house phones. Pressing the Call button on the RE-1 will cause the RE-1 to disconnect the house phones from the telephone company line and generate a ring signal that is heard on the house phones.
7 MUL TIPLE UNIT INST ALLA TIONS Any of the f our basic operation modes (Shared Line, Dedicated Line , Intercom, and Ring Down) ma y be used with multiple RE-1s in the same installation. The telephone line wiring is “daisy chained” (the telephone line routes through one unit to the next) as sho wn below .
8 CONTROL WIRING Gate Control 1. Route two wires between the gate and the RE-1. Connect the gate operator’ s OPEN ter minals to the RE-1 Relay #1 COM & N.O . terminals. ✦ NO TE: For operator wiring specifi cs, refer to the gate oper ator’ s wiring diagram.
9 POWER, BA TTERY , & GROUND WIRING Pow er Wiring ✦ NO TE: DO NO T APPL Y PO WER UNTIL THE IN S T ALLA TION I S COMPLETE. 1. Route two wires between the RE-1 and the pow er transformer . • F or power wire runs up to 100 feet, use 18 A WG, THHN 600-volt insulated wire.
10 OPTIONAL KEYSWITCH A ke yswitch can be installed in the RE-1 Entry System to provide keyed access. The RE-1 case is designed to accept the f ollowing ke yswitch: KNO X COMP ANY MODEL 3 501 KNO X COMP ANY 800-552-5669 www .knoxbo x.com Keyswitch Installation 1.
11 OPTIONAL CCTV CAMERA Linear’ s Model RE-BWC1 (P/N A CP00886A) CCTV camera can be installed inside the RE-1 Entry System. The camera provides a video signal for vie wing the area in front of the entry system. The camera is continuously po wered by the RE-1.
12 PROGRAMMING ACCESS The RE-1 can be programmed locally or remotely . The system’ s built-in progr amming software can be accessed on-site or off-site using a computer with any Internet browser .
13 1. FROM CONTROL PANEL S ELECT "NETWORK CONNECTION S " THEN S ELECT "NEW CONNECTION WIZARD" 2. THE NEW CONNECTION WIZARD WILL S TART CLICK "NEXT" 3. NEW CONNECTION WIZARD - "NETWORK CONNECTION TYPE" S ELECT "CONNECT TO THE INTERNET" OPTION 4.
14 2. CLICK "DIAL" TO S TART THE CONNECTION 6. AFTER CONNECTING, S WITCH TO YOUR MICRO S OFT INTERNET EXPLORER BROW S ER S OFTWARE AND ENTER THI S ADDRE SS : http://192.16 8 .20.10/re1.html 3. THE MODEM WILL DIAL THE NUMBER CONNECTING TO THE RE-1 WITH WINDOWS XP™ 1.
15 1. FROM THE S TART MENU, CLICK ON "CONNECT TO" SETTING UP A WINDOWS VISTA™ DIAL-UP NETWORK CONNECTION (PART 1) 2. CLICK ON " S ETUP A CONNECTION OR NETWORK" 3. CHOO S E " S ET UP A DIAL-UP CONNECTION" 4. CLICK ON THE MODEM TO BE U S ED FOR THE CONNECTION 5.
16 7. CLICK ON "CLO S E" SETTING UP A WINDOWS VISTA™ DIAL-UP NETWORK CONNECTION (PART 2) 8 . FROM THE S TART MENU, CLICK ON "CONNECT TO" AND S ELECT "RE-1" 9. IN THE CONNECT WINDOW, S ELECT "PROPERTIE S " 10. CLICK ON "CONFIGURE" AND UN-CHECK ALL HARDWARE FEATURE S 11.
17 1. CLICK ON "DIAL" S TART THE CONNECTION CONNECTING TO THE RE-1 WITH WINDOWS VISTA™ 2. THE MODEM WILL DIAL THE NUMBER 3. ONLY WHEN CONNECTING REMOTELY, AFTER THREE RING S , CLICK "CANCEL", WAIT 10 S ECOND S THEN REPEAT S TEP S 1-3.
18 LOCAL PROGRAMMING ACCESS Programming with a Local T elephone or the Unit’ s Keypad Star t with Step 1 below f or local programming with the unit’ s keypad or a local telephone. 1. Enter “ ### ” (unless the prog ramming prefi x has been changed) then the Master Programming Code (123456, unless it has been changed), then “ # ”.
19 PROGRAMMING REFERENCE PROGRAMMING CONTROL USAGE KEYSTROKES ENTER PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .###MASTER CODE# ESCAPE/CANCEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20 BASIC SYSTEM PROGRAMMING Entering Programming Mode The 6-digit Master Programming Code (def ault = 123456) is used to enter Programming Mode from a local or remote telephone or the k eypad.
21 TRANSMITTER PROGRAMMING Adding T ransmitters Up to 24 groups of transmitters can be assigned common access privileges sharing the same one or two time zones.
22 Call Forw arding Featur e Default: OFF The call forw arding feature will allo w a visitor to contact the resident at the programmed telephone number instead of through the local telephone line. The f eature can be set to be active during a selected Time Zone or at all times.
23 Relay #2 Alternate Options Default: Access Relay Relay #2 can be used f or functions other than tr iggering a gate operator or door strike. Relay #2 can be programmed to shunt alarm contacts during Relay #1 activ ation or perf or m up to fi ve Alarm Functions.
24 Keypad Beeps On/Off Default: On The default setting causes the main k eypad to beep when each k ey is pressed. The beeps can be disab led. Press: Keypad Beeps Ke ypad Beeps: 0 = Beeps OFF 1 = Beeps ON Relay #1 T one On/Off Default: Off The default setting does not cause the ann unciator to sound when Relay #1 is activated.
25 RE-1 OPERA TION Requesting Access with an Entry Code • Visitors hav e up to 40 seconds to key in their entry code. • Up to eight seconds are allowed between each k eystrok e. • All digits of the entr y code must be entered. Example: If the code is 0042, the user must enter “0 0 4 2”.
26 RESIDENT PROGRAMMING QUICK REFERENCE Some of the programming PPN’ s may be commonly used b y the resident. Following are quic k references to the k eystrok es required. ✦ NO TE: The “###” is the default command prefi x. The follo wing example assumes that the def ault has not been changed.
27 SPECIFICA TIONS MECHANICAL Case dimensions: 6.45” W x 10.81” H x 3.74” D ELECTRICAL V oltage: 16 V olts AC or 12-24 Volts DC Current: 650 mA AC typical, 1300 mA AC maxim um Backup Battery: Ex.
28 PROGRAMMING WORKSHEET S E N O Z E M I TS E N O Z E M I T S E N O Z E M I T S E N O Z E M I TS E N O Z E M I T S Y A D E V I T C AS Y A D E V I T C A S Y A D E V I T C A S Y A D E V I T C AS Y A D E.
29 E D O C Y R T N EE D O C Y R T N E E D O C Y R T N E E D O C Y R T N EE D O C Y R T N E# Y A L E R# Y A L E R # Y A L E R # Y A L E R# Y A L E RE N O Z E M I TE N O Z E M I T E N O Z E M I T E N O .
LINEAR LIMITED WARRANTY This Linear product is warranted against def ects in mater ial and workmanship for tw enty-four (24) months . The W arranty Expiration Date is labeled on the product. This w arranty e xtends only to wholesale customers who buy direct from Linear or through Linear’ s normal distr ibution channels.
デバイスLinear RE-1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Linear RE-1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLinear RE-1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Linear RE-1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Linear RE-1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Linear RE-1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLinear RE-1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Linear RE-1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLinear RE-1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。