F r e e d o m Fireplace Insert Owner's Manual • Masonry Fireplace Insert Save these instructions for future reference S A FE TY N OTIC E : If thi s appl i anc e i s not properly i ns tal l ed, a house fi re may re sult. For y our s afety, follow the install ation dire cti ons.
2 Introduction © Travis Industries 100-01162 4041105 Introduction We welcome you as a new owner of a Lopi Freedom wood-burning fireplace insert. In purchasing a Lopi Freedom you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics.
Table of Contents 3 © Travis Industries 100-01162 4041105 General Information Introduction ...................................................... 2 Important Information ......................................... 2 Safety Precautions .................
4 Safety Precautions © Travis Industries 100-01162 4041105 The viewing door must be closed and latched during operation. Never block free airflow through the air vents on this appliance. Gas Gasoline or other flammable liquids must never be used to start the fire or "Freshen Up" the fire.
Safety Precautions 5 © Travis Industries 100-01162 4041105 Mobile Home When installed in a mobile home, this appliance must be bolted to the floor, have outside air, and not be installed in the bedroom (Per H.U.D. requirements). Check with local building officials.
6 Features & Specifications © Travis Industries 100-01162 4041105 Installation Options: • Masonry Fireplace Insert WARNING : Do not install this fireplace insert into a factory-built metal (Z.C.) fireplace. Features: • EPA Phase II Approved • 2.
Installation (for qualified installers only) 7 © Travis Industries 100-01162 4041105 SAFETY NOTICE: P lease r ead t h is ent ir e m an u al b ef o r e yo u in stall an d u se yo u r n ew r o o m h eater . F ailu r e to fo llo w in st r u c tio n s m a y r e su lt in p r o p er t y d am a g e, b o dily injur y, or even d eath .
8 Installation (for qualified installers only) © Travis Industries 100-01162 4041105 Fireplace Requirements Figure 2 shows the minimum size requirements for the type of fireplace used.
Installation (for qualified installers only) 9 © Travis Industries 100-01162 4041105 Insert Placement Requirements • The insert must be placed so that no combustibles are within, or can swing within (e.
10 Installation (for qualified installers only) © Travis Industries 100-01162 4041105 Drafting Performance This appliance relies upon natural draft to operate. External forces, such as wind, barometric pressure, topography, or factors of the home (negative pressure from exhaust fans, chimneys, air infiltration, etc.
Installation (for qualified installers only) 11 © Travis Industries 100-01162 4041105 Block-Off Plate Installation Whenever this appliance is installed with a direct connection a block-off plate, or other non-combustible seal-off device (e.g. damper adapter), will need to be installed.
12 Installation (for qualified installers only) © Travis Industries 100-01162 4041105 Insert with Positive Connection The liner must be stainless steel connector or flexible vent. Follow the liner manufacturer's insturctions for installation and support.
Installation (for qualified installers only) 13 © Travis Industries 100-01162 4041105 Insert with Direct Connection (Masonry Fireplace) Block-off plate or damper adapter Remove damper or wire it open.
14 Operating Your Appliance © Travis Industries 100-01162 4041105 Safety Notice: If this appliance is not properly installed, a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area.
Operating Your Appliance 15 © Travis Industries 100-01162 4041105 Bypass Operation The bypass controls the flow of smoke inside the heater. When pulled out, smoke goes directly up the flue, creating more draft. When pushed in, the smoke goes around the baffle, utilizing the secondary combustion and making the heater more efficient.
16 Operating Your Appliance © Travis Industries 100-01162 4041105 Starting a Fire Since the dawn of time man has debated the best way to start a fire. Some use the boy-scout "tee-pee", some prefer the "tic-tac-toe" stack. Either way, review the hints and warnings below to ensure proper fire starting.
Operating Your Appliance 17 © Travis Industries 100-01162 4041105 Adjusting the Burn Rate Use the air control slider to control the burn rate of the stove. See the illustration below for details. Low Burn (air control closed) High Burn (air control open) Use the air control to change the burn rate.
18 Operating Your Appliance © Travis Industries 100-01162 4041105 Optional Blower Operation The blower will turn on once the stove is up to temperature. This is typically 15 to 30 minutes after starting the fire. Follow the directions below to alter the blower speed.
Operating Your Appliance 19 © Travis Industries 100-01162 4041105 Hints for Burning • Get the appliance hot before adjusting to low burn • Use smaller pieces of wood during start-up and high burn.
20 Operating Your Appliance © Travis Industries 100-01162 4041105 Troubleshooting Problem Possible Cause Smoke Enters Room During Start-Up • Open the bypass (pg. 15). • Open the air control (pg. 17). • Cold Air Blockage - burn a piece of newspaper to establish a draft.
Maintaining Your Appliance 21 © Travis Industries 100-01162 4041105 Failure to properly maintain and inspect your appliance may reduce the performance and life of the appliance, void your warranty, and create a fire hazard. Daily Maintenance (while stove is in use) Remove Ash (if necessary) • Ash removal is not required once it builds up.
22 Maintaining Your Appliance © Travis Industries 100-01162 4041105 Monthly Maintenance (while appliance is in use) Make sure the appliance has fully cooled prior to conducting service. Door and Glass Inspection The door must form an air-tight seal to the firebox for the stove to work correctly.
Maintaining Your Appliance 23 © Travis Industries 100-01162 4041105 Yearly Maintenance Make sure the appliance has fully cooled prior to conducting service. Touch Up Paint Included with the owner's pack of this appliance is a can of Stove-Brite® paint.
24 Maintaining Your Appliance © Travis Industries 100-01162 4041105 Door Parts 9/16" Wrench 5 10 8 9 12 7 6 3 4 1 2 11 NOTE : Place the glass gasket around the perimeter of the door retainer.
Maintaining Your Appliance 25 © Travis Industries 100-01162 4041105 Firebox Parts 1 3 2 12 12 15 13 14 10 10 10 10 10 4 5 10 10 10 9 8 10 10 11 11 6 7 ID # Description Qty Part # ID # Description Qty.
26 Maintaining Your Appliance © Travis Industries 100-01162 4041105 Baffle Removal & Replacement 1 Lift up on the front portion of the front three firebricks. 2 Lift the front baffle support “Y” and rotate it forward until it can be removed. 3 Slide the center front firebrick forward and out the door opening.
Limited 7 Year Warranty 27 © Travis Industries 100-01162 4041105 To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC.
28 Listing Label © Travis Industries 100-01162 4041105 Listing Label MODEL: FREEDOM (FLEX ) T ested to: UL-1482/UL-907 Report No. 6009 (Mar ch 1990) DO NO T REMO VE THIS LABEL Listed Solid Fuel Burning Appliance Suitable for use in masonry fireplaces.
Optional Equipment 29 © Travis Industries 100-01162 4041105 Door Shell Installation 1. Remove the door retainer shipping latch following the directions below. Standard Screwdriver Rotate this shaft 1/4 turn clockwise until the door unlatches. Swing the door retianer open.
30 Optional Equipment © Travis Industries 100-01162 4041105 3. Attach the retainer to the shell following the directions below. Make sure the door retainer is centered on the door shell.
Optional Equipment 31 © Travis Industries 100-01162 4041105 Flush Kit This kit allows the Freedom insert to be installed with more of the unit inside the fireplace (flush) rather than extended onto the hearth. The flush kit must be installed prior to installing the surround panels or placing the insert.
32 Optional Equipment © Travis Industries 100-01162 4041105 Surround Panels SURROUND PANEL SIZE HEIGHT WIDTH PART # 8" 29-1/2" 45-3/8 " 99300293 10" 31-1/2" 49-3/8 " 99300294 12" 33-1/2" 53-3/8 " 99300295 Installation Instructions 1.
Optional Equipment 33 © Travis Industries 100-01162 4041105 Front Blower (part # 99000133) To Switch The Power Cord To The Left Side: Use a pair of pliers to disconnect the strain relief which holds the power cord in place. With the power cord slackened, the molex connectors that attach the power cord to the blower assembly may be disconnected.
34 Index © Travis Industries 100-01162 4041105 Air Control (Burn Rate) ...................................1 7 Air Tube Part Number ....................................2 5 Air Tube Removal & Replacement ....................2 6 Ash Disposal .......
デバイスLopi Freedom Fireplace Insertの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lopi Freedom Fireplace Insertをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLopi Freedom Fireplace Insertの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lopi Freedom Fireplace Insertの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lopi Freedom Fireplace Insertで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lopi Freedom Fireplace Insertを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLopi Freedom Fireplace Insertの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lopi Freedom Fireplace Insertに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLopi Freedom Fireplace Insertデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。