COUNTERFLOW W ALL FURNACE INST ALLA TION AND OPERA TING INSTRUCTIONS P/N 781 1 1 REV . 03/05 24 VOL T SYSTEM NA TURAL GAS CF353C-H CF503C-H CF653C-H WITH LOW-BTU PILOT L . P . GAS CF354C-H CF504C-H CF654C-H MODEL NUMBERS 24 VOL T SYSTEM NA TURAL GAS CF357C-H CF557C-H WITH INTERMITTENT IGNITION (I.
CONTENTS Contents……………………………………………........... 2 Introduction…………………………………………. 2 Specifications……………………………………….. 2 Safety Rules………………………………………… 3 Helpful Installation Information……………….
SAFETY RULES 1 . Improper installation, adjustment, alteration, service or maintenance can cause property damage, bodily injury or death. If you do not understand these instructions or your local codes, call local authorities, a qualified installer , service agency , gas su pplier , or the manufacturer .
VENTING - CONTINUED This appliance is equipped with a blocked flue switch. W ARNING: Do not bypass the blocked flue switch. T o do so could expose the consumer to property damage, personal injury or possible death.
COMBUSTION AND VENTILA TION AIR When installed, this gas appliance must be provided with fresh air for combustion, ventilation, and dilution of hot flue gases. The minimum required volume of the area where the appliance is installed should be 50 cubic feet per 1,000 btu/hr .
LOCA TION AND SPECIAL PRECAUTIONS The wall furnace should be located near the center of the house for best heat distribution. If the area where the appliance is to be installed contains carpeting, til.
GAS ROUGH-IN Check local codes for requirements as to the size and type of gas line required. See Figure 5 for location of gas inlet holes in furnace cabinet. Compounds used on threaded joints of gas pipe should be resistant to the action of liquefied petroleum gases.
INST ALLA TION / WHEN RECESSED (UP T O 9-1/4”) STEP 1 . Cut out floor plate between 2x4 studs, so heater will set flat on floor . STEP 2 . Make electrical connection of 115 V . wiring into junction box provided on top of header plate. STEP 3. Attach the base plate (purchased with the vent pipe) to the header plate using two No.
Installation of B-W Gas V ent for one-story buildings or for first floor of multi-story buildings. Ceiling plate spacers to center B-W Gas V ent in stud space - nail securely at both ends. Plate cut away for full width of stud space to provide ventilation.
CF353C-H, CF354C-H, CF503C-H, CF504C-H, CF653C-H, CF654C-H ST ANDING PILOT FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life.
CF357C-H, CF358C-H, CF557C-H, CF558C-H - I.I.D. PILOT FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life. LIGHTING INSTRUCTIONS T O TURN OFF GAS TO APPLIANCE Page 11 1.
PROPER BURNER FLAME A proper flame will have a dark blue inner mantle that sits right on top of the burners with a lighter blue outer mantle rising above the burner , (See Figure 1 1). There may be some yellow where the pilot flame and burner flame meet.
TERMINAL BLOCK WIRING DIAGRAM CAUTION: Label all wires prior to disconnection when servicing controls. W iring errors can cause improper and dangerous operation. V erify proper operation after servicing. AUXILIAR Y LIMIT SWITCH For your safety this furnace is equipped with a manual reset auxiliary limit switch.
CF353C-H, CF354C-H ST ANDING PILOT CF503/504C-H, CF653/654C-H Page 14 CF353C-H, CF354C-H PICTORIAL SCHEMA TIC Thermostat Power Cord Black Black Green White White Black Black Black White Black Black Br.
CF357C-H, CF358C-H I.I.D. CF557C-H, CF558C-H Page 15 BLACK BLACK BLACK AUXILIAR Y LIMIT SWITCH SPILL SWITCH PILOT IGNITION MODULE MV/PV GAS V AL VE LIMIT SWITCH FAN SWITCH SELECTOR SWITCH BLACK BROWN .
ROUGH-INS FOR REAR OR SIDE DISCHARGE Install plastergrounds as shown in Figure 12 and Figure 13. NOTE: When side discharge is being used, furnace should be set exactly 4” from side wall. 14-3/8” 10-3/ 16” Plaster Ground SIDE FIGURE 13 REAR FIGURE 12 OPTIONAL ACCESSOR Y KITS REAR REGISTER KIT (Flush Mount) (See Figur e 14) 1.
SIDE DISCHARGE ON CASING 1. Use optional kit No. 306SR-A. 2. Cut out and remove embossed area on casing side. 3. Remove knockout from inner liner . 4. Place 1-1/2” boot from kit through opening, matching flanges of boot to knockout on inner boot. 5.
SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION Flame too large 1. Defective operator section of gas valve. 1. Replace complete valve. 2. Burner orifice too large. 2. Check with local gas company for proper orifice size and replace. 3. If installed above 2,000 ft.
SYMPT OM POSSIBLE CAUSES CORRECTIVE ACTION Pilot won’t light, 1. Air in line. 1. Bleed line. or stay lit 2. Defective thermocouple. 2. Replace thermocouple. (ST ANDING PILOT) 3. Pilot flame too low . 3. Adjust pilot flame. 4. Manual reset switch not engaged.
REV . 03/05 COUNTERFLOW W ALL FURNACE / ST ANDING PILOT Prices and specifications subject to change without notice. All prices are F .O.B. factory . MODELS: NA T .
24 VOL T SYSTEM WITH LOW-B.T .U. ST ANDING PILOT NA TURAL CF353C-H CF503C-H CF653C-H MODEL NUMBER L . P . CF354C-H CF504C-H CF654C-H RE F . P ART L IS T P ART LIST P A R T LIST P AR T DESCRIPTION NUMBER NUMBER PRICE NUMBER PRICE NUMBER PRICE Casing Side, Right 1 30055 $48.
REV . 03/05 COUNTERFLOW W ALL FURNACE / I.I.D. PILOT Prices and specifications subject to change without notice. All prices are F .O.B. factory . MODELS: NA T .
24 VOL T SYSTEM WITH INTERMITTENT NA TURAL CF357C-H CF557C-H MODEL NUMBERS L . P . CF358C-H CF558C-H RE F . P AR T LIST P AR T LIST P AR T DESCRIPTION NUMBER NUMBER PRICE NUMBER PRICE Casing Side, Right 1 30055 $48.40 3 05 2 5 $52.10 Casing Side, Left 1 a 30060 $48.
REV . 03/05 Page 24 KIT NO. 31300-A TRIM KIT VENT ENCLOSURE KIT NO. 16VE-A or 36VE-A KIT NO. 406RR-A REAR REGISTER W/ BOOT - FLUSH KIT NO. 407RR-A REAR REGISTER - RECESS KIT NO. 30SRB-A SIDE REGISTER W/BOOT KIT NO. 306SR-A SIDE REGISTER - FLUSH For description of above refer ence numbers, see reverse side.
P ARTS LIST FOR ACCESSORIES FOR COUNTERFLOW W ALL FURNACE P ART DESCRIPTION REF . NO. P ART NO. LIST PRICE 16" V ent Enclosure Side 1 31360 $8.20 16" V ent Enclosure Front 2 31355 $10.30 24" V ent Enclosure Side 1 31367 $12.60 24" V ent Enclosure Front 2 31366 $15.
IMPOR T ANT SAFETY BULLETIN ON YOUR GAS CONTROL AND PILOT LIGHT SYSTEM FOR HEA TING EQUIPMENT WHA T YOU DON’T KNOW CAN HUR T YOU. Y our pilot light system has been designed for safe and reliable operation. Although safety mechanisms ar e built-in, the potential for hazard exists.
LIMITED WARRANTY LIMITED WARRANTY LIMITED WARRANTY LIMITED WARRANTY LIMITED WARRANTY The Louisville T in & Stove Co. warrants to the original user the accompanying product for the period specified.
デバイスLouisville Tin and Stove CF654C-Hの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Louisville Tin and Stove CF654C-Hをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLouisville Tin and Stove CF654C-Hの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Louisville Tin and Stove CF654C-Hの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Louisville Tin and Stove CF654C-Hで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Louisville Tin and Stove CF654C-Hを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLouisville Tin and Stove CF654C-Hの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Louisville Tin and Stove CF654C-Hに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLouisville Tin and Stove CF654C-Hデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。