CAUTIONS AND W ARNINGS . . . . . . . . . . 2 SYSTEM COMP A TIBILITY . . . . . . . . . . . . 3 FEA TURES . . . . . . . . . . . . . . . . . . . . . . . 4 TOOLS YOU MA Y NEED . . . . . . . . . . . . . . 4 MOUNTING LOCA TION . . . . . . . . . . . . . . 5 REMOVE OLD THERMOST A T .
2 • This thermostat requires batteries to opera te and failure or sub-standard performance of the batteries may impair or prevent the correct operation of the thermostat. Use Duracell ® or Energizer ® alkaline batteries ONL Y for all LUXPRO thermostats requiring batteries.
F an A ut o O n H ea t O ff C oo l LCD Display Screen P111 UP and DOWN Buttons Fan Mode Switch SET Button System Mode Switch The electrical rating for this thermostat is 1.5 Amps per terminal, with a maximum total combined load of 2.0A for all terminals combined.
• Non-programmable operation • Lighted display • Keypad lockout for unauthorized users • Adjustable temperature differential / cycle-rate • User temperature calibration • Adjustable heat/c.
On replacement installations, mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise. On new installations, please follow these general guidelines: 1. Mount the thermostat on an inside wall, about 5 ft. (1.
1. Strip wire insulation leaving only 3/8 in. (9.5mm) bare wire ends, and clean off any corrosion present. 2. F ill the wall opening with non-combustible insulation to prevent drafts from affecting the thermostat’ s normal opera tion. 3. Separate new thermostat housing using your thumb and index finger .
CONNECTING THE WIRES: When attaching the wires to the thermostat, please ensure that the bare wire ends are held ALL the way into the terminal block while the screw is being tightened. WIRING BASE PLA TE NOTICE: This thermostat model is part of a family of similar models that have the same general visual appearance.
WIRING DIAGRAM NOTES: (Important, please read all notes before connecting wires) • If the information provided in the following wiring diagrams does not clearly represent or match your system, please refer to the “TECHNICAL ASSIST ANCE” section of this manual, and contact us before removing any of your existing thermostat wiring.
9 #1 CONVENTIONAL: HEA TING ONL Y .................................................. 1 0 SINGLE-ST AGE 2 , 3 , o r 4 W IR E S #2 CONVENTIONAL: COOLING ONL Y ................................................. 1 1 SINGLE-ST AGE 3 or 4 WIRES #3 CONVENTIONAL: HEA TING AND COOLING .
2 / 3 / 4 WIRES CONVENTIONAL, NON HEA T PUMP 1-ST AGE, HEA T ONL Y (INCLUDING MILLIVOL T) NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC W1 4 W X F G RH V R Fa.
Y1 6 Y A/C UNIT 3 / 4 WIRES CONVENTIONAL, NON HEA T PUMP 1-ST AGE, COOL ONL Y NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC X F G Factory RH-RC Jumper Wire In.
Y1 6 Y A/C UNIT 4 / 5 WIRES CONVENTIONAL, NON HEA T PUMP 1-ST AGE HEA T AND 1-STAGE COOL NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC W1 4 W X F G RH V R Fac.
Y1 6 Y A/C UNIT 5 / 6 WIRES CONVENTIONAL, NON HEA T PUMP 1-HEA T / 1-COOL, WITH TWO-TRANSFORMERS NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC W1 4 W X F G R .
B* Y1 6 Y H E A T PUMP 4 / 5 WIRES HEA T PUMP SYSTEMS 1-HEA T / 1-COOL, WITH NO AUXILIARY / EMERG. HEA T NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC X F G B.
INST ALL BA TTERIES INTO THERMOST A T : Install two brand new Energizer ® o r DURACELL ® “AA ” size alkaline (only) batteries, into the thermosta t’ s battery compartment.
B/O CIRCUIT BOARD OPTION (FOR HEA T PUMP APPLICA TIONS): This setting is a plastic shorting cap (called a jumper) which determines the operation of the shared B/O wire terminal connection.
HEA T / OFF / COOL, SY STEM MODE SWITCH: Set this switch to HEA T to control your heating system, and COOL to control your cooling system. The OFF position will disable both the heating and cooling units.
Setup options for how the thermostat will function, along with choosing your particular system type, are performed using a menu on the display screen. TO ACCESS THE SETUP MENU: Move the System Mode switch into the OFF position, and then hold down the SET button for approximately 5 seconds until the screen changes.
ITEM #07 (DELA Y TIME): [1] (default) 5 Minutes. Thermostat waits 5 minutes before turning the system back on after it was last run. The 5 minute setting is fine for most applications, and provides equipment protection by preventing rapid cycling. [2] Same operation as above, but reduced to 2 minutes between state changes if desired.
HEA TING AND COOLING : Basic operation of your heating or cooling system can be obtained by choosing either HEA T or COOL with the System Mode switch. The temperature can be adjusted using the UP and DOWN buttons. LCD DISPLA Y BACKLIGHT : The display screen is lighted to assist viewing at nighttime, or in locations with low light levels.
KEYP AD LOCKOUT : Y ou can lock the front panel buttons to prevent unauthorized tampering of your thermostat settings. TO LOCK THE KEYP AD: Start with the thermostat at rest, and the display backlight NOT illuminated.
This thermostat is powered by two “AA ” Alkaline batteries. The batteries should be replaced A T LEAST once per year to ensure reliable operation (or sooner if the battery icon or “LO BA TT” appears in the display screen). The batteries are located on the back of the thermostat’ s circuit board.
If this unit fails because of defects in materials or workmanship within three years of the date of original purchase, LUX will, at its option, repair or replace it. This warranty does not cover damage by accident, misuse, or failure to follow installation instructions.
24 www .luxproproducts.com 856-234-8803 F a n A u t o O n H e a t O f f C o o l.
デバイスLux Products P111の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lux Products P111をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLux Products P111の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lux Products P111の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lux Products P111で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lux Products P111を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLux Products P111の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lux Products P111に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLux Products P111デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。