1 Installation Guide IMPORT ANT SAFETY INFORMA TION WARNING: • Always turn off power at the main power source by unscrewing fuse or switching circuit breaker to the off position before installing, removing, cleaning, or servicing thermostat. • Read all of the information in this manual before installing or programming this thermostat.
Features • Four setpoints for weekday programming—two setpoints for weekend comfort. • T wo “AA” ENERGIZER brand batteries retain program memory, even during power outages. • Low battery indicator . • Fahrenheit/Celsius display option. • Programmable from 45°F (4°C) to 90°F (32°C).
Figure 1 Installing the Model 8353 Thermostat NOTE: For new installations, mount thermostat on inside wall, 4-5 feet above the floor . Do not install behind a door , in a corner , near air vents, in direct sunlight, or near any heat or steam generating fixtures.
Figure 3 7. Drill the marked holes using a 3/16” drill bit. Note: Enclosed plastic anchors do not require a drilled hole for drywall. 8. T ap plastic anchors into the wall. 9. Align base with plastic anchors and feed wires through opening. See Fig 4.
13. Install two “AA” ENERGIZER brand batteries or equivalent into battery compartment. Be sure to match positive (+) ends of batteries with positive (+) battery terminals in the battery compartment. The display will show as follows: 14. Replace cover onto thermostat by snapping into place.
5. Press 6. Press T o change T emperature Differential* *The T emperature Differential is Factory preset at 1°. This means that whenever the room temperature changes by one full degree from the temperature setting, the system will turn on. If the system turns on too often, increase the temperature differential.
4. Press SET . 5. Press or to change MORN temperature. 6. Repeat Steps 2-5 for DA Y , EVE, and NITE. 7. Press SET to finish. 8. Shift COOL-OFF-HEA T switch to HEA T position. 9. Repeat steps 2-7 to program HEA T (winter) settings. NOTE: Both summer and winter programs use the same time settings.
T emporary Program Override T o temporarily increase or decrease temperature Press or The thermostat will automatically return to the program at the next scheduled setting change or after four hours. Manual Operation Manual operation allows continuous override of the program settings.
T o T est Thermostat WARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS V ALVE OR SYSTEM CONTROL TO TEST OPERA TION. THIS WILL DAM- AGE THE THERMOST A T AND VOID YOUR WARRANTY . CAUTION: Do not switch system to cool if the temperature is below 50°F (10°C).
T roubleshooting Symptom Remedy Thermostat does not turn Check Wiring on system (see INST ALLA TION). Check fuse. Replace with 2 amp Slo-Blo fuse if fuse has opened. Thermostat turns on and off too Increase T emperature Differential frequently . (see PROGRAMMING).
Wiring Diagrams The following is just a sample of the most common types of HV AC sys- tems. Refer to your systems installation manual for wiring information.
Limited W arranty Y our Resear ch Products Corporation Aprilaire ® Thermostat unit is expressly warranted for two (2) years from date of installation to be free from defects in materials and workmanship.
デバイスAprilaire 8353の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Aprilaire 8353をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAprilaire 8353の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Aprilaire 8353の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Aprilaire 8353で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Aprilaire 8353を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAprilaire 8353の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Aprilaire 8353に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAprilaire 8353デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。