Datalogger ™ DataLogger and DataPulse Software Instruction Manual Febuary 2005 © Copyright 2005 Magnetek.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 1 of 16 ©2005 ELECTROMOTIVE SYSTEMS All rights reserved. This noti ce applies to all copyri ghted mate rials included with this product , including, but not li mited t o, this manual and software embodied wit hin the product.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 2 of 16 Section 1: Overview The DataLogger Series 3 was designed to simplify troubleshooting and provide for detailed operational histories that are necessary for genuine preventive maintenance.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 3 of 16 How data logging works: The DataLogger is a device which polls the Drive via the RS232 CN1 port. Once connected, the logger will r ead the Inverter Status and U1 parameters. From the Inve rter Status, the logger can detect when the drive is running or when a fault or alarm occurs.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 4 of 16 Logging of Run, Fault, Alarm and Trace Data All Data collection is automatic, viewing data is per the various screens, and the roadmap of functions per the diagram on the Menu Navigation on page 6.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 5 of 16 14912, 14920, 14940, 14960, 14961, 14962, 14964, 14965, and 14980. For connection to Series 3 drives, simply replace the keypad with the data logger. The DataLogger will automatically begin logging after a 2 second boot up.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 6 of 16 DATALOGGER MENU NAVIGATION -Main Menu- Monitor Fault History Alarm History Run History Upload from VFD Download from VFD Clear Data Settin.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 7 of 16 The Monitor Mode provides for Real-Time di splay of Inverter operation. It also indicates the total number of Run events, Alarm and Fault events.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 8 of 16 The Fault History provides the data for reviewing recorded faults and information on each fault occurrence. -FAULT HISTORY - Flt: 1 OF 6 Run: 5 Ext Fault S7 01/16/04 02:37 01/28/04 08:44:13 - FAULT HISTORY - U2-03: 030.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 9 of 16 The Alarm History provides the data for reviewing recorded alarms and information on each alarm occurrence. -ALARM HISTORY - Alm: 1 OF 26 Run: 1369 Upper Limit1 Err 01/16/04 15:14 01/28/04 08:44:13 Date & Time: Used to time stamp all history and trace data.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 10 of 16 The Run History provides the data for reviewing information on each time the drive receives a run command or a change in direction. -RUN HISTORY - Run: 220 OF 260 Forward 01/16/04 15:14 Duration: 40 Secs 01/28/04 08:44:13 Date & Time: Used to time stamp all history and trace data.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 11 of 16 Introduction to DataPulse Series 3 software DataPulse is a user friendly, Windows based, DataLogger communication software that will allow the viewing of logger data in a spreadsheet format.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 12 of 16 Navigating DATAPULSE Series 3 MENU Upload data from Datalogger View parameter data View Run data View Alarm data View Fault data Uploadin.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 13 of 16 Viewing parameter sets Selecting the button will display the parameter sets that are stored in the logger. Double click on the parameter set of inte rest and the parameter information is displayed.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 14 of 16 Displaying Drive History Data Selecting the button will display the fault history window. Selecting the button will display the alarm history and selecting the button will display the run history window.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 15 of 16 Select the data that you want to di splay by selecting in the check box..
Impulse DataLogger Series 3 Instruction Manual 2/1/05 16 of 16 PRINTING It is best to print only the desired informati on from the thousands of pieces of data stored in the logger. To edit and print this information, you would save the file as a *.CSV file which is a “comma separated variable” file.
デバイスMagnetek Series 3の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Magnetek Series 3をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMagnetek Series 3の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Magnetek Series 3の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Magnetek Series 3で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Magnetek Series 3を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMagnetek Series 3の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Magnetek Series 3に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMagnetek Series 3デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。