MANLEY LABORATORIES, INC. OWNER'S MANUAL CONTROL MASTER PREAMPLIFIER MANLEY LABORATORIES, INC. 13880 MAGNOLIA AVE. CHINO, CA. 91710 TEL: (909) 627-4256 FAX: (909) 628-2482 email: emanley@netcom.
CONTENTS INTRODUCTION 3 MAINS CONNECTIONS 4 CONNECTING YOUR PREAMPLIFIER 5 FIGURE 1 FRONT PANEL 6 FIGURE 2 REAR PANEL 7 OPERATIONAL NOTES 8 SPECIFICATIONS 9 WARRANTY 10 WARRANTY REGISTRATION 11 SECTIO.
INTRODUCTION ! THANK YOU!... for choosing the Manley Laboratories CONTROL MASTER Preamplifier. Designed by David Manley, the Mastering Room LINE Preamplifier uses the best available parts with the shortest, cleanest, signal path possible. With the use of our own in-house C.
MAINS CONNECTIONS Your preamplifier has been factory set to the correct mains voltage for your country. The voltage setting is marked on the serial badge, located on the rear panel. Check that this com- plies with your local supply. Export units for certain markets have a moulded mains plug fitted to comply with local require- ments.
CONNECTING YOUR PREAMPLIFIER Setting up your preamplifier is rather easy. 1. Please refer to page 7 diagram 2 for an illustration of the back of the preamplifier. 2. There are two sets of main outputs, one set UNBALANCED RCA and the other BALANCED XLR.
FRONT PANEL OPERAT E MUT E BALANCE TRIM LEFT RIGHT VOLUM E XL R AU X DI G TAP E TUNE R VIDE O A B C D E F A SELECTOR SWITCH Switch to select between inputs.
REAR PANEL A IEC MAINS SOCKET Standard IEC mains socket (120/240 VAC) B FUSE HOLDERS Right & Left channel fuses. Replace with 1A SLO-BLO fuse only. C VOLTAGE SELECTOR SWITCH Selectable to 110,120 / 220,240 VAC. Set to the proper voltage for your country.
OPERATIONAL NOTES SWITCHING ON The power switch is located on the right hand corner of the front panel. Flip the switch up to turn on the preamplifier and down to turn off the preamplifier. RUNNING It is not recommended that you leave your preamplifier permanently switched on.
SPECIFICA TIONS Vacuum Tubes: 2 x 5814's, 2 x 6414's Gain (line stage) 6 dB Input Impedance 100 Kohm line stages Output Impedance 120 ohms Power Consumption 33 Watts (275mA @ 120VAC).
W ARRANTY All Manley Laboratories equipment is covered by a limited warranty against defects in materials and workmanship for a period of 90 days from date of purchase to the original purchaser only.
WARRANTY REGISTRATION We ask that you please fill out this registration form and send the bottom half to: MANLEY LABORATORIES REGISTRATION DEPARTMENT 13880 MAGNOLIA AVE. CHINO CA, 91710 Registration entitles you to product support, full warranty benefits, and notice of product enhancements and upgrades.
デバイスManley Labs CONTROL MASTER PREAMPLIFIERの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Manley Labs CONTROL MASTER PREAMPLIFIERをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはManley Labs CONTROL MASTER PREAMPLIFIERの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Manley Labs CONTROL MASTER PREAMPLIFIERの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Manley Labs CONTROL MASTER PREAMPLIFIERで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Manley Labs CONTROL MASTER PREAMPLIFIERを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はManley Labs CONTROL MASTER PREAMPLIFIERの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Manley Labs CONTROL MASTER PREAMPLIFIERに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちManley Labs CONTROL MASTER PREAMPLIFIERデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。