W ARNING : Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer , service agency or the gas supplier .
.
3.
4 PROPER LOCA TION FOR INST ALLING YOUR HEA TER Carefully select the location of your new heater . For your safety and for proper heater operation, you must provide an abundant supply of combustion air and a proper venting installation. The heater may still operate even when improperly vented.
5 COMBUSTION AIR REQUIREMENTS Observe the following instructions concerning combustion air . Appliances located in unconfined spaces: a) An unconfined space is one whose volume is greater than 50 cubic feet per 1000 Btu per hour of the combined rating of all appliances installed in the space.
6 Fig. 3 - Flue Adaptor for High Altitude Installations 5” X 6” ADAPTOR USED ON HIGH AL TITUDE MOUNTING INST ALLA TION The Aquastar 125 B “S” is design certified for mounting on a wall. Do not install this appliance on a carpeted wall or over floor covering which is combustible, such as carpet.
7 W ARNING : Failure TO INCREASE THE VENT SIZE TO SIX INCHES AND/or assure that the manifold pressure is set to proper value listed for applications at high altitudes will cause unsafe venting, asphyxiation, and will void IAS Certification.
8 FOR YOUR SAFETY READ BEFORE LIGHTING THE PILOT W arning : If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life A. This appliance has a piezo-igniter for lighting the pilot burner .
9 INFORMA TION ABOUT W A TER TEMPERA TURE The AquaStar 125B LPS and 125B NGS water heaters have a gas control that modulates burner output in response to water flow . Its purpose is to ensure that the hot water temperature will remain steady , although the water flow demand might vary (down to 1/2 gal/minute).
10 TROUBLE SHOOTING Introduction The AquaStar 125 B “S” burners are activated by a water flow valve. Numerous water related problems can cause this water valve to malfunction such as: Insufficient.
11 BURNERS DO NOT IGNITE WHEN HOT W A TER IS TURNED ON 1. Pilot is not on. Light the pilot. See lighting instructions. 2. Gas valve button not positioned on Burner Position Be sure once the pilot flame is on, that after a 15 to 20 second wait, the main burner button ( ) is pushed all the way in.
12 the AquaStar ’s outlet pipe with your hand) and at the tap. If these two are very different, check for mixing valve or plumbing crossover (see “MAIN BURNERS WILL NOT IGNITE...” paragraph #6). 6. Parts in water flow valve are corroded so that the gas passage is not fully opening.
13.
14 AQ 125 BS Fig. 1 1 - INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST.
15 Fig. 1 1 INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST 125BS 1 Cover 8 705 421 033 2 Cap cover 8 703 304 01 1 3 Panel back 8 705 402 164 4 Draft divertor 8 705 505 354 5 Heat exchanger 8 705 406 189 .
Replacement Parts available from North American Distributor CONTROLLED ENERGY CORP . 340 Mad River Park V ermont 05673 (U.S.A.) Phone 800-642-31 1 1 Fax (802) 496-6924 WWW .CECHOT .COM VULCANO T ermodomésticos S.A. Estrada de Cacia 3800 Cacia - PORTUGAL Recycled paper techsupport@cechot.
デバイスAquaStar 125B LPSの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
AquaStar 125B LPSをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAquaStar 125B LPSの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。AquaStar 125B LPSの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。AquaStar 125B LPSで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
AquaStar 125B LPSを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAquaStar 125B LPSの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、AquaStar 125B LPSに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAquaStar 125B LPSデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。