AquaStarメーカー125B NGの使用説明書/サービス説明書
ページ先へ移動 of 16
W ARNING : Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer , service agency or the gas supplier .
2 This well engineered, gas water heater has all the fea- tures a water heater should have: It operates on the principle of heating water instantaneously “on demand”. When a hot water faucet is opened, cold water flows through the coils of the heat exchanger in the Aquastar .
3.
4 If you are using the AquaStar for combined space heating and potable water heating (see schematic diagram below) , all piping and other components connected to the system must be suitable for potabl.
5 4. Y ou must vent your heater. See section on V ent Pipe Connections, Page 5. 5. The appliance must be disconnected from the gas supply piping system during any pressure testing at pressures in excess of 1/2 Psig (3.
6 CLEARANCES The Aquastar 125 B is design certified for installation on a combustible wall and for installation in an alcove with the minimum clearances to combustible and non -combustible construction listed below A. T op 12 inches ( 305 mm) B. Front Open C.
7 The flue connection for the AquaStar 125B is 5 inches. However , in Canada, for installations at high altitude (2000- 4500 feet above sea level) a six inch flue is required. A 5" by 6" flue adaptor must be affixed to the flue collar of the AquaStar with at least two screws.
8 OPERA TING INSTRUCTIONS Before proceeding with the operation of the heater make sure that the system is filled with water . Make sure the water heater drain plug is closed. See Figure 7 below . Fig. 7 - W ater heater drain plug Open the cold water inlet supply to the heater fully .
9 LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above on this plate. 2. The Gas valve must be turned off by sliding the gas valve button to the far left under the OFF ( ) mark. 3. W ait five (5) minutes to clear out any gas. If you smell gas, STOP! Follow “B” in the safety information above on this plate.
10 TROUBLE SHOOTING Introduction The AquaStar 125 burners are activated by a water flow valve. Numerous water related problems can cause this water valve to malfunction such as: Insufficient water flo.
11 6 . Faulty thermocouple (part #8747202083) or electromagnet ) Unless these 2 parts are at least 8 to 10 years old, it is very unlikely that they are faulty . Before testing, reconfirm that #2 is absolutely correct, and that all connections are clean and tight.
12 PILOT LIGHT GOES OUT DURING OR IMMEDIA TEL Y AFTER HOT W A TER HAS BEEN USED 1. Gas pressure too low V ery low gas pressure may be caused by low delivered gas pressure, a jammed gas regulator or undersized gas lines. If the gas lines are undersized, there may still be the specified static gas line pressure.
13 Fig. 1 1 - Diagram of AquaStar 125 B 5 11 1 4 9 10 1. Heat exchanger 2. Pilot assembly 3. Burner manifold gas pressure test nipple 4. Main gas burner 5. Pilot gas tubing 6. Gas valve 7. Pressure tap screw location 8. Gas control slide 9. Piezo igniter 10.
14 Fig. 12 - INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST.
15 Fig. 12 INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST 125B 1 Cover ¤ 8 705 421 025 2 Plastic collar ¤ 8 700 403 008 3 T emperature adjustment knob ¤ 8 702 000 1 1 1 4 Panel back ¤ 8 705 402 164 5.
Replacement Parts available from North American Distributor CONTROLLED ENERGY CORP . 340 Mad River Park V ermont 05673 (U.S.A.) Phone 800-642-31 1 1 Fax (802) 496-6924 WWW .CECHOT .COM VULCANO T ermodomésticos S.A. Estrada de Cacia 3800 Cacia - PORTUGAL Recycled paper techsupport@cechot.
デバイスAquaStar 125B NGの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
AquaStar 125B NGをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAquaStar 125B NGの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。AquaStar 125B NGの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。AquaStar 125B NGで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
AquaStar 125B NGを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAquaStar 125B NGの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、AquaStar 125B NGに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAquaStar 125B NGデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。