® ® Revision 1.0 Page i TMP100 Temperature Module User’s Manual Revision 1.0 Copyright © 2008 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N.
TMP100 User's Manual Page ii Revision 1.0 Revision History Revision Description 1.0 Original document.
® ® Revision 1.0 Page iii Table of Contents 1 Introduc tion .................................................................................................................. ......... 1 1.1 Firmware Revi sion ...........................
TMP100 User's Manual Page iv Revision 1.0 Table of Appendices Appendix A – NMEA 2000 ® Interfacing ............................................
® ® Revision 1.0 Page 1 1 Introduction Congratulations on your purchase of the Ma retron Temperature Modul e. Maretron has designed and built your TMP 100 to the highest standards for years of dependable and accurate service.
TMP100 User's Manual Page 2 Revision 1.0 - Ambient Air Temperature Probe (-20° C to 80°C or -4°F to 176°F) - Ring Terminal Probe (-20°C to 80°C or -4°F to 176°F) - Immersion Probe for Tanks or Plenums (-20°C to 80°C or -4°F to 176°F) - Exhuast Gas Temperature Probe (0°C to 900°C or 32° to 1652°F) 1.
® ® Revision 1.0 Page 3 2.3 Mounting the TMP100 Attach the TMP100 securely to the vessel usi ng the included stainle ss steel mounting screws or other fasteners as shown in Figure 1 below .
TMP100 User's Manual Figure 2 – NMEA 2000 ® Connector Face Views 2.4.2 Temperature Probe Connections The TMP100 temperature probe connections are made by connecting to the 12-pin terminal strip on the top of the unit. First, remove the f our screws at the corners of the unit detaching the splash guard from the unit.
® ® 2.4.2.1 Exhaust Gas Temperature (EGT) Probe The TP-EGT-1 exhaust gas temper ature probe may be used to measure temperatures other than exhaust gas temperatures; however, the TP -EGT-1 exhaust gas temperature probe is the only TMP100 temperature probe that has su fficient range to measure exhaust gas temperature.
TMP100 User's Manual Please refer to Figure 4 for connecting the TMP100 to a TR3K ring/under bolt thermistor temperature probe, TP-AAP-1 ambient air te mperature probe, or TP-IP-1 immersion temperature probe.
® ® Revision 1.0 Page 7 Temperature, Inside Tem perature, Engine Room Te mperature, Main Cabi n Temperature, Live Well Temperature, Bait Well Te mperature, Refrigeration Te mperature, Heating System Temperature, Freezer Temper ature, Exhaust Gas Temper ature, and User Defined Temperature #129-#144.
TMP100 User's Manual Page 8 Revision 1.0 2.5.5.3 Installation Description… The TMP100, along with all other Level A certified NMEA 2000 devices, has two user- programmable installation description fields.
® ® Revision 1.0 Page 9 5 Technical Specifications As Maretron is constantly impr oving its products, all specificat ions are subject to change without notice.
TMP100 User's Manual Page 10 Revision 1.0 128723 Temperature, High Range (Exhaust Gas Temperatur e) 0.5 times/second Electrical Parameter Value Comment Operating Voltage 9 to 32 Volts DC Voltage Power Consumption 50 mA NMEA 2000 ® Interface Load Equivalence Number (LEN) 1 NMEA 2000 ® Spec.
® ® 7 Installation Template Please check the dimensions before using the fo llowing diagram as a template for drilling the mounting holes because the printing proc ess may have distorted the dimensions. Figure 5 – Mounting Surface Template Revision 1.
TMP100 User's Manual Page 12 Revision 1.0 8 Maretron (2 Year) Limited Warranty Maretron warrants the TMP100 to be free from defects in materials and workm anship for t wo (2) years from the date of original purchase.
® ® Revision 1.0 Appendix A – NMEA 2000 Interfacing Page A1 Appendix A – NMEA 2000 ® Interfacing TMP100 NMEA 2000 ® Periodic Data Transmitted PGNs PGN 130310 – Environmental Parameters ( not.
TMP100 User's Manual Page A2 Appendix A – NMEA 2000 Interfacing Revision 1.0 PGN 130312 –Temperature The TMP100 uses this PGN to provide a regul ar transmission of various temperatures. The factory default for periodic transmission rate is once every two seconds.
デバイスMaretron TP-EGT-1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Maretron TP-EGT-1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMaretron TP-EGT-1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Maretron TP-EGT-1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Maretron TP-EGT-1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Maretron TP-EGT-1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMaretron TP-EGT-1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Maretron TP-EGT-1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMaretron TP-EGT-1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。