Marshall E lectronics NCB-1004 Network Contr ol Box for IMD M onitors Operating Instr uctions.
.
3 3 Contents Product Ov erview ....................................................................... ....................................................................... .................... 4 Features ............................................
4 Product Over view The NCB-10 04 Net work Control box is a com prehensiv e remote c ontrol solutio n for Mars hall’s IMD (In- Monitor Display) line of m onitors. T he NCB-1004 of fers complete contr ol of each monitor's menu settings and adj ustm ents such as contrast, col or, curtain c olor, as pect ratio, and more.
5 Install ation and Power- On ■ Unpacking Carefull y unpack the NC B-1004 and verif y that the f ollowing i tems are included: • NCB-1004 Network Control Box • V-PS12-5V-1 Power S uppl y with 2-Pin T wist Lock Connector • Operating Instructions Inspect the u nit for an y phys ical dam age that ma y have occurred d uring shi pping.
6 Front and Rear Panel Features RS-422 Out puts The RS-422 outputs sen d MEI pr otocol com mands to Marshal l’s IMD line of monitor s. Each out put has exactly the s am e signal. Up to 1 28 screens c an be connected to each outp ut. T hese output ports a lso pass Im age Video or T SL v4.
7 Connecting to the NCB-1004 Overview The NCB-10 04 can be operated b y any com puter with a web bro wser, via a T CP/IP net work connec tion. No a dditional software is needed. T he NCB-10 04 ma y be connecte d directl y to a singl e com puter, or connec ted to a l ocal area net work and acces sed by mult iple com puters .
8 Connecti ng to t he NCB-100 4 (conti nued) Connecting the NCB-1004 to a Single Computer (cont inued) 8. Click O K in the Intern et Prot ocol (T CP/IP) Propertie s window, an d then cl ick Close i n the Local Area Connection Propertie s windo w. 9. Open an y web browser application (Internet Explorer, Firefox , etc.
9 Connecti ng to t he NCB-100 4 (conti nued) Connecting the NCB-1004 to a Local A rea Netw ork If the networ k portion of the unit’s IP addres s (firs t three number s) matc hes your network , the NCB- 1004 can be connected to a local ar ea net work and acc essed fr om any com puter on th e network .
10 Changing t he IP Address of the NCB-1004 Overview The NCB-10 04 is ship ped with a d efault IP addr ess of 192. 168.0.233 . T his IP a ddress can be chang ed via t he network connection. Note that t he existing IP add ress must be known to make th is change.
11 Changing t he IP Address o f the NCB-1004 ( cont inued) Procedure (continued) 5. At the pass word prom pt shown bel ow, do not e nter a password a nd sim ply click O K : 6.
12 Changing t he IP Address o f the NCB-1004 ( cont inued) Procedure (continued) 8. The f ollowing file inf ormation s hould appear : 9. This f ile must be edited t o save the new IP ad dress. Us e the followin g comm ands to ed it the file. Ed it only the numbers.
13 System C onfiguration Overview The NCB-10 04 can be used in thr ee diff erent system configurat ions. The f ollowing di agram s show the dif ferent configurat ions: Basic Remote Control of IMD Monito rs ■ Overview Use the follo wing conf iguration for basic r emote c ontrol of Mars hall IMD ser ies m onitors.
14 System Co nfigu ration (conti nued) Remote Control with Image Video Pass-Through ■ Overview Use the follo wing conf iguration for basic r emote c ontrol of Mars hall IMD ser ies m onitors, whi le also pas sing thr ough Image Video pr otoco l.
15 System Co nfigu ration (conti nued) Remote Control with TSL Pass-Through ■ Overview Use the follo wing conf iguration for basic r emote c ontrol of Mars hall IMD ser ies m onitors, whi le also pas sing thr ough TSL v4.
16 Web Int erface Overview The web inter face is use d to op erate the NC B-1004. O nce the NCB-100 4 is conne cted to a net work, acc ess the web interface b y entering the units IP address in any web b rowser on a ny com puter on the network .
17 Web Inter face ( continued) Window Management The W indow Managem ent page is shown b elow: Use the butt ons and m enus sho wn above for th e follo wing settings : o As pect Ratio ( 4:3, Scaled 4:3.
18 Web Inter face ( continued) Preset Configuration The Preset Co nfigurat ion page is shown be low: Use the butt ons shown a bove to l oad and s ave prese ts in each m onitor. Note that thes e controls af fect the pr esets in each m onitor onl y. There are no presets in th e NCB-10 04 itself.
19 Web Inter face ( continued) OSD Configuration & IMD The OSD Conf igurat ion & IMD page is sho wn below: Use the first s ection of the OSD & IMD pag e to set th e protoco l pass-th rough s ettings : o Set Protoco l (Image V ideo, T SL) – Select th e protoc ol type to be passed thr ough the NCB- 1004.
20 Web Inter face ( continued) S y stem The System page is s hown bel ow: Use the butt ons shown a bove to s end the f ollowing co mm ands: o Ping (Healt hy, Unhe althy) – T est a comm and and respons e with a m onitor. o Get Softw are Version – Reads th e m ain software ver sion of a m onitor.
21 Web Inter face ( continued) Table of Web Interface Commands Aspect Rat io 4:3, Scaled 4:3, 16:9, 16:9 Center ed Set Marker Off, On Window Managemen t Set Center Off, On Set Backgroun d Transparent,.
22 Specifications ■ CONT ROL INPUT Connector 1 x RJ12 (Modular 6 P6C) Ph y sical Layer RS-422 Data Protoco ls Image Video: Start Bits 1 Data Bits 7 Parity Even Stop Bits 1 Baud Rate 3840 0 TSL v4.
Specifica tions (cont inued) Warrant y Marshall El ectronics warranties to th e first c onsum er that this NCB- 1004 LCD m onitor will, under norm al use, be f ree fr om defects in workm anship and m aterials, when recei ved in its origin al container, for a peri od of one year f rom the purchas e date.
Marshall Electr onics, Inc . 1910 East Maple Ave. El Segundo, CA 90245 Tel: (800) 800-6608 / (310) 333-0606 • Fax : 310-333-0688 www.LCDRacks.com • sales@lcd racks.
デバイスMarshall electronic NCB-1004の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Marshall electronic NCB-1004をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMarshall electronic NCB-1004の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Marshall electronic NCB-1004の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Marshall electronic NCB-1004で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Marshall electronic NCB-1004を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMarshall electronic NCB-1004の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Marshall electronic NCB-1004に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMarshall electronic NCB-1004デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。