MartinLoganメーカー33ISDGの使用説明書/サービス説明書
ページ先へ移動 of 40
This is an unvented gas- fi red heater . It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided.
2 23D8036 CONTENTS Important Safety Information ..................................3 Product Features ......................................................5 Operation ..............................................................5 Natural Gas ........
23D8036 3 9. The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.l/NFPA54. 10. This unit complies with ANSI Z21.11. Unvented Heat- ers. 11. Do not install the heaters in a bathroom or bedroom.
4 23D8036 IMPORT ANT SAFETY INFORMA TION Continued from page 3 16. Keep room area clear and free from combustible materi- als, gasoline and other flammable vapors and liquids. 17. Unvented gas heaters are a supplemental zone heater. They are not intended to be the primary heating appli- ance.
23D8036 5 Your vent-free fireplace must be mounted to the floor or the fireplace hearth. OPERA TION This unvented gas heater requires no outside venting and burns cleanly with high heating efficiency.
6 23D8036 NA TURAL GAS Milli-Volt and T-Stat Pressure Regulator Pressure Setting: 3.5" w.c. Pilot Regulator: 3.5" w.c. Gas Inlet Pressure: Max. 10 1/2" w. c. Min. 5" w.c. PRODUCT FEA TURES AND SPECIFICA TIONS PROP ANE/LPG Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.
23D8036 7 GETTING ST ARTED MAKE SURE YOU HA VE RECEIVED ALL P ARTS Check your packing list to verify that all listed parts have been received. You should have the following: • Installation/Operating instructions • Black Louvers (5) • 33" unvented gas heater with brick panels.
8 23D8036 REMOVING SCREEN Remove fireplace screen by pushing screen frame panel up and out. See Figure 2. Figure 2 - Removing Fireplace Screen GENERAL INST ALLA TION INFORMA TION INST ALLING CANOPY 1. Remove the fireplace screen as described in the previous section.
23D8036 9 GENERAL INST ALLA TION INFORMA TION CODES Adhere to all local codes or, in their absence, the latest edition of THE NATIONAL FUEL GAS CODE ANSI Z223.1 or NFPA54 which can be obtained from… American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 or National Fire Protection Association, Inc.
10 23D8036 W H BTU/Hr = BTU/Hr = W ARNING The following formula can be used to determine the maximum heater rating per the definition of unconfined space: (L 1 + L 2 ) Ft x (W) Ft x (H) Ft 50 Consider two connecting rooms with an open area between, with the following dimensions: L 1 = 15 1 / 2 Ft.
23D8036 11 33" 15 1 / 4 " 22 3 / 4 " 23 7 / 8 " B A 9" Minimum 9" Minimum 42" Minimum CLEARANCES AND HEIGHT REQUIREMENTS NOTE: Clearances are necessary to combustible surfaces only . No clearance is necessary for noncombustible surface.
12 23D8036 10" 12" 14" 26" 8" 12" 10" 8" 6" 2 1 / 2 " Hood No combustible materials within 8” of opening. Do not cover louv ers. No combustible materials within 8" of opening. Do not cover louvers.
23D8036 13 Combustible Material Non-combustible Material 5" 1” CLEARANCES and HEIGHT REQUIREMENTS The gas log heater must be installed at least 5" above any combustible flooring material, such as carpeting or tile, which is closer than 14" to the base of the fireplace.
14 23D8036 22 5 / 8 " 33 1 / 2 " 16 " 33 1 / 2 " 16 " 33 1 / 2 " 27 1 / 2 " 22 5 / 8 " 31 7 / 8 " REF 16 " 37 1 / 4 " 45 3 / 4 " 15 3 / 8 &q.
23D8036 15 NOTE: Clearance requirements as detailed in “Clearances and Height Requirements” section of this manual must be met before securing heater in place. To prevent movement, the heater must be secured to the floor or hearth. 1. Lift off louvers and remove the screen.
16 23D8036 NOTICE: A quali fi ed gas appliance installer must connect the heater to the gas supply . Consult all local codes. IMPORT ANT : Loosen the pipe adapter on the fl ex tube before installing to the system piping. Figure 17 - Gas Connection T o Heater V alve Stainless Flexible T ube CONNECTING THE GAS Use new black or steel pipe.
23D8036 17 To reach factory installed flex line, go through access door on right or left side of firebox. CONNECTING THE GAS CHECK GAS TYPE: The gas supply must be the same as stated on heater's rating plate. Located behind the control access door (Figure 1, page 5).
18 23D8036 CHECKING GAS PRESSURE Test all gas joints from the gas meter to the heater valve for leaks using a gas analyzer or soap and water solution after com- pleting connection. DO NOT USE AN OPEN FLAME. Check the gas pressure with the appliance burning and the control set to HIGH .
23D8036 19 ELECTRICAL WIRING (MILLI-VOL T) The milli-volt valve is a self-powered combination gas control THA T DOES NOT REQUIRE 1 10 V AC TO OPERA TE.
20 23D8036 ELECTRICAL WIRING (MILLI-VOL T) A. COMPLETE MILLIVOL T SYSTEM CHECK (“A” Reading - Thermostat contacts CLOSED - Control Knob “ON” - Main burner should turn ON) a. If the reading is more than 100 milli-volts and the automatic valve still does not come on, replace the control.
23D8036 21 ELECTRICAL WIRING (F AN) If any of the original wire as supplied with the fireplace must be replaced, contact dealer for proper replacement wiring har- ness. (see parts list for part number) . 120 volts, 60Hz, 1 amps. Electrical power cord (plug) can be routed to exit the 33ISD on either the left side or the right side.
22 23D8036 LOG PLACEMENT Figure 19 - Installing Right Base Log (#1) Before you begin — This unit is supplied with six (6) ceramic fi ber logs. Do not handle these logs with your bare hands. Always wear gloves to pr event skin irritation fr om ceramic fi bers.
23D8036 23 LOG PLACEMENT Figure 21 - Installing Left Base Log (#3) Left Base Log (#3) Pins Figure 22 - Installing Right T op Log (#4) Right top log (#4) Pins 4. Place right top log (#4) on two pins located to the left of right base log. See Figur e 22.
24 23D8036 LOG PLACEMENT Figure 23 - Installing Left T op Log (#5) Left Top Log (#5) 5. Place right end of left top log (#5) on bottom center grate pin.
23D8036 25 LOG PLACEMENT 6. Place right front log (#6) on two pins on the right front of grate. See Figur e 25. Figure 25 - Installing Right Front Log (#6) Pins Right Base Log Right Front Log (#6) Extrusions PLACING ROCK WOOL After installing logs, place TPB-R W (Rock W ool) in dime-size pieces evenly across the burner surface in between the logs.
26 23D8036 FLAME APPEARANCE Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed. In addition, periodically check the flames visually during operation. CHECKING THE PILOT FLAME The pilot fl ame must always be present when the heater is in operation.
23D8036 27 In normal operation at full rate after 15 minutes, the following flame appearances should be observed: Figure 33 - Correct Appearance of Rear Flames Burner will have a random pattern of yellow flames as shown in Figure 33. There should be glowing embers on the front burner.
28 23D8036 W ARNING Figure 34 - Location of Piezo Ignitor , Control Knobs and Switch on Milli-V olt Unit, Hi/Lo Remote Control and Manual Unit A. This appliance is equipped with a piezo ignition device which automatically lights the pilot. If pilot is not working see Match Lighting Instructions on page 30.
23D8036 29 OPERA TING INSTRUCTIONS 1. STOP! Read the safety information label. 2. Make sure the manual shutoff valve is fully open. 3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo ignitor does not light the pilot, refer to instructions for “Match Lighting Instructions,” page 30.
30 23D8036 1. Remove any items necessary for easy access to the pilot (for example: logs, screens, etc.). 2. Follow appropriate lighting instructions found previously. Instead of pushing and releasing the piezo button, light a match and hold the flame to the end of the pilot and ignite the pilot.
23D8036 31 Annual inspection and cleaning by your dealer or qualified service technician is recommended to prevent malfunction and/or sooting. PERIODIC CLEANING - Refer to parts diagram for location of items discussed below . • Do not use cleaning fluid to clean logs or any part of heater.
32 23D8036 OBSERVED PROBLEM When ignitor button is pressed, there is no spark at ODS/pilot. Appliance produces unwanted odors. Appliance shuts off during use. Gas odor even when control knob is in OFF position. When ignitor button is pressed, there is spark at ODS pilot, but no ignition.
23D8036 33 OBSERVED PROBLEM ODS/pilot lights, but flame goes out when control knob is released. Burner does not light after ODS/ pilot is lit. Burner backfires during com- bustion. Slight smoke or odor during initial operation. Logs appear to smoke after ini- tial operation.
34 23D8036 1 2 3 4 8 8 8 8 8 8 13 7 5 6 14 12 Failure to position the parts in accordance with these diagrams or failure to use only parts speci fi cally approved with this appliance may result in property damage or personal injury .
23D8036 35 REPLACEMENT P ARTS LIST Item Qty Description DIS33N/P 1 1 Screen Assembly 23D8028 2 1 Canopy Assembly 23D8027 3 3 T op Black Louver 23D0200K 4 1 Bottom Black Hang On Louver Assembly 23D8016.
36 23D8036 5 6 3 4 8A 8B 1 2 7 ILLUSTRA TED P ARTS BREAKDOWN Failure to position the parts in accordance with these diagrams or failure to use only parts speci fi cally approved with this appliance may result in property damage or personal injury .
23D8036 37 REPLACEMENT P ARTS LIST REPLACEMENT P ARTS ARE A V AILABLE THROUGH YOUR RET AILER. Item Description Qty 33ISDN 33ISDP Common Parts 1 Piezo Ignitor 1 14D0503 14D0503 2 Piezo Wire 1 00K0632 0.
38 23D8036 #2 #1 #3 #4 #5 #6 REPLACEMENT P ARTS ARE A V AILABLE THROUGH YOUR RET AILER. ILLUSTRA TED P ARTS BREAKDOWN Failure to position the parts in accordance with these diagrams or failure to use only parts speci fi cally approved with this appliance may result in property damage or personal injury .
23D8036 39 NOTES.
MA Y 2006 P/N 23D8036 • Rev . 1 LIMITED LIFETIME W ARRANTY POLICY The following components are warranted for life to the original owner, subject of proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate, and Stainless Steel Burners.
デバイスMartinLogan 33ISDGの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
MartinLogan 33ISDGをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMartinLogan 33ISDGの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。MartinLogan 33ISDGの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。MartinLogan 33ISDGで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
MartinLogan 33ISDGを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMartinLogan 33ISDGの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、MartinLogan 33ISDGに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMartinLogan 33ISDGデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。