POR T ABLE GASOLINE GENER A T OR S OWNER’S OPERA TION AND INST ALLA TION MANUAL R IMPORTANT: Read and understand this manual before operating or servicing generator. Improper use of generator can cause serious injury. Keep this manual for future reference.
2 105420 POR T ABLE GASOLINE GENERA TORS R 1. Gasoline presents a hazard of fire or e x- plosion. Gasoline is flammable. Its va- por is explosi ve. •K eep fuel out of children’ s reach. • Refuel generator in a well-vented area. Do not fill fuel tank in the dark.
3 105420 OWNER’S MANUAL F U E L F FUEL F 120 ONLY 120 240V R E S E T T E S T 1 2 0 V O L T S 120/240 VOLTS RESET RESET E N M 0 0 0 0 0 0 0 5 H O U RS 1/10 F U L L P O W E R 9. Only a qualified electrical service per - son should service and repair generator .
4 105420 POR T ABLE GASOLINE GENERA TORS R VENTILA TION DUST , DIRT , RAIN, AND SNOW HIGH AND LOW TEMPERA TURE OPERA TION Air temperature affects generator output. Output drops 1% for each 10 ° temperature rise above 60 ° F. Very low temperatures may make the engine hard to start.
5 105420 OWNER’S MANUAL SPECIFICA TIONS MGH5000C MGH4000C MGH5000CI MGH6000C MGH7000C MODEL HWI3000 MGH3000 MGH3000PR MGH4000CI MGH5000CIE MGH6000CI MGH7000CI MGH10000 Electrical Rated Wattage 2500 2500 2500 4000 5000 6000 7000 10,000 Rated Amperage 120 V 20.
6 105420 POR T ABLE GASOLINE GENERA TORS R 120/240 VOLT Position 120 VOLT ONLY Position Figure 3 - Full Power Selector Switch GENERA TOR FEA TURES OIL ALERT SYSTEM The oil alert system protects the engine from low oil damage. This system automatically shuts down the engine and prevents engine restarting if the oil level falls too low.
7 105420 OWNER’S MANUAL ENGINE CIRCUIT BREAKER (Models MGH5000CIE, MGH7000C, MGH7000CI, and MGH10000) This circuit breaker, or fuse, protects the battery charging circuit. A short circuit will trip the circuit breaker. The circuit breaker will also trip if you install battery wrong.
8 105420 POR T ABLE GASOLINE GENERA TORS R F U E L F Figure 10 - Battery Hold-Down System (Model MGH7000C Shown) 1 2 0 O N L Y 1 2 0 2 4 0 V E N M 0 0 0 0 0 0 0 5 H O U R S 1 / 1 0 F U L L P O W E R B.
9 105420 OWNER’S MANUAL Ampere AWG for Length of Load Cord in Feet 50' 100' 150' 21 8 1 8 1 8 31 8 1 8 1 8 41 6 1 6 1 6 51 6 1 6 1 6 61 6 1 6 1 4 81 6 1 4 1 2 10 16 14 12 12 14 14 12 .
10 105420 POR T ABLE GASOLINE GENERA TORS R OPERA TION GENERAL INFORMATION This generator is not large enough to power your entire home. Do not connect generator to any existing electrical circuits. Plug items directly into generator receptacles. Do not exceed amperage rating of receptacles.
11 105420 OWNER’S MANUAL RESET 240 VO LTS R ESET RESET RESET RESET TEST 120 VOLTS R E SE T R ES ET E N M 0 0 0 0 0 0 0 5 H O U R S 1 /1 0 120 ONLY 120 240V Figure 15 - Receptacle Locations 120V, 15-.
12 105420 POR T ABLE GASOLINE GENERA TORS R Choke Lever (Open Position) Figure 23 - Choke Lever Opened (Model MGH7000C Shown) HIGH ALTITUDE OPERATION This generator will not perform well at high altitudes without proper adjustment. See engine owner’s manual for details.
13 105420 OWNER’S MANUAL OPERA TION Continued Figure 25 - Fuel Valve Lever Off (Model MGH7000C Shown) Fuel Valve Lever (Off Position) 1. Check items to be po wered. Their nameplate lists their wattage ratings. Note: The wattage ratings for some electrical motors are misleading.
14 105420 POR T ABLE GASOLINE GENERA TORS R WARNING: Only a qualified electrical service person should service and repair generator. Use only factory approved replacement parts. POSSIBLE CAUSE 1. Defecti ve capacitor 2. W inding short circuit or loose connections 3.
15 105420 OWNER’S MANUAL WIRING DIAGRAMS Figure 26 - Wiring Diagram, Models HWI3000, MGH3000, and MGH3000PR Circuit Breaker 25A 120/240V 20A Receptacle T4 120V, 15A Receptacle 120V, 30A Receptacle W.
16 105420 POR T ABLE GASOLINE GENERA TORS R 120/240V 30A Receptacle T4 120V, 15A Receptacle Circuit Breaker 20A Green Black Black Black Red Black T3 White Green Red T1 T2 White White Circuit Breaker 3.
17 105420 OWNER’S MANUAL PA R TS CENTRALS These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original re- placement parts and accessories.
18 105420 POR T ABLE GASOLINE GENERA TORS R This list contains replaceable parts used in your generator. When ordering parts, fol- low the instructions listed under Replace- ment Parts on page 17 of this manual. ILLUSTRA TED PA R TS LIST For Models HWI3000, MGH3000, and MGH3000PR Alternator Assembly † Includes fastening hardware.
19 105420 OWNER’S MANUAL PART NUMBER FOR MODEL MGH5000C KEY MGH4000C MGH5000CI MGH6000C MGH7000C NO. MGH4000CI MGH5000CIE MGH6000CI MGH7000CI DESCRIPTION QTY.
20 105420 POR T ABLE GASOLINE GENERA TORS R 1 5 16 14 24 10 26 18 19 6 2 11 12 9 3 7 4 22 23 25 17 21 8 20 15 13 ILLUSTRA TED PA R TS LIST For Model MGH10000 Alternator Assembly This list contains replaceable parts used in your generator. When ordering parts, follow the instructions listed under Replacement Parts on page 17 of this manual.
21 105420 OWNER’S MANUAL ILLUSTRA TED PA R TS LIST For Models HWI3000, MGH3000, and MGH3000PR Roll Cage This list contains replaceable parts used in your generator. When ordering parts, follow the instructions listed under Replacement Parts on page 17 of this manual.
22 105420 POR T ABLE GASOLINE GENERA TORS R 9 10 11 12 13 11 16 13 13 17 17 18 11 11 11 16 11 16 21 20 19 14 23 14 23 23 16 16 16 16 10 11 16 11 16 22 F U E L F 1 3 2 4 24 7 8 6 6 27 7 25 15 5 26 ILLU.
23 105420 OWNER’S MANUAL KEY PART NO. NUMBER DESCRIPTION QTY. 1 25954000 Gas Cap/Fuel Gage 1 2 099832-01 Gas Tank (with 90 ° fitting) 1 3 25978000 Breather Assembly 1 4 M51043-01 Screw, 1/4-20 x 1&.
24 105420 POR T ABLE GASOLINE GENERA TORS R 9 10 12 15 33 11 17 13 24 24 18 11 24 5 11 20 11 19 16 14 23 36 35 34 21 25 24 13 27 22 FU EL F 1 3 2 4 26 6 37 7 11 32 25 24 34 11 25 24 8 29 30 31 28 24 1.
25 105420 OWNER’S MANUAL ILLUSTRA TED PA R TS LIST For Model MGH10000 Fuel Tank and Roll Cage This list contains replaceable parts used in your generator. When ordering parts, fol- low the instructions listed under Replace- ment Parts on page 17 of this manual.
26 105420 POR T ABLE GASOLINE GENERA TORS R PART NUMBER FOR MODEL MGH5000C KEY MGH4000C MGH5000CI MGH6000C MGH7000C NO. MGH4000CI MGH5000CIE MGH6000CI MGH7000CI DESCRIPTION QTY.
27 105420 OWNER’S MANUAL † Includes reference numbers 1 through 16 ∆ Not shown KEY PART NO. DESCRIPTION NUMBER QTY. 1 Control Panel 103182-01 1 2 20 Amp Circuit Breaker 22616009 2 3 120V , 30A T.
KEEP THIS WARRANTY W ARRANTY INFORMA TION FIVE-YEAR LIMITED WARRANTY GASOLINE PORTABLE GENERATORS DESA Power Tools™ warrants each alternator, generator, or electric product of its manufacture, to be.
デバイスMaster Lock MGH3000PRの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Master Lock MGH3000PRをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMaster Lock MGH3000PRの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Master Lock MGH3000PRの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Master Lock MGH3000PRで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Master Lock MGH3000PRを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMaster Lock MGH3000PRの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Master Lock MGH3000PRに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMaster Lock MGH3000PRデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。