1 W10096988A W10306460A-SP DR YER SAFETY ......................................................................... 2 INST ALLA TION REQUIREMENTS ............................................. 3 T ools and Parts .........................................
2 DR YER SAFETY You You can be killed or seriously injured if you don't immediately can be killed or seriously injured if you don't follow All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
3 INST ALLA TION REQUIREMENTS T ools and Parts Gather the requir ed tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
4 If you are using power supply cor d, a grounded electrical ■ outlet located within 2 ft. (610 mm) of either side of dryer . See “Electrical Requirements.” A sturdy oor to support the total weight (dryer and load) ■ of 200 lbs. (90.7 kg). The combined weight of a companion appliance should also be considered.
5 Electrical Connection T o properly install your dryer , you must determine the type of electrical connection you will be using and follow the instructions provided for it her e. If local codes do not permit the connection of a neutral ■ ground wir e to the neutral wire, see “Optional 3-wir e connection” section.
6 Install Leveling Legs Prepar e dryer for leveling legs 1. T o avoid damaging oor , use a large at piece of car dboard from dryer carton; place under entir e back edge of dryer . Firmly grasp dryer body (not console panel) and gently lay dryer down on cardboar d.
7 Electrical Connection Power Supply Cord W ARNING Fire Hazar d Use a new UL listed 30 amp power supply cord. Use a UL listed strain relief. Disconnect power before making electrical connections. Connect neutral wire (white or center wir e) to center terminal (silver).
8 Put power supply cord thr ough the strain relief. Be sur e that the wire insulation on the power supply cor d is inside the strain relief. The strain r elief should have a tight t with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief scr ews at this point.
9 3-wir e Power Supply Cor d Connection Use where local codes permit connecting cabinet-gr ound conductor to neutral wire. A B D C E F G A. 3-wire receptacle (NEMA type 10-30R) B. 3-wire plug C. Neutral prong D. Spade terminals with upturned ends E. 3/4" (19 mm) UL listed strain relief F .
10 4-wir e Direct Wir e Connection IMPORT ANT : A 4-wire connection is r equired for mobile homes and where local codes do not permit 3-wir e connections. 5. Prepar e to connect neutral ground wir e and neutral wir e E A B Remove center , silver -colored terminal block scr ew (B).
11 3-wir e Direct Wir e Connection Use where local codes permit connecting cabinet-gr ound conductor to neutral wire. B 5. Remove center screw Remove center , silver -colored terminal block scr ew (B). 7. Connect ground wir e A F Connect ground wir e (green or bar e) (F) of direct wir e cable to external ground conductor screw (A).
12 1. Prepar e to connect neutral ground wir e and neutral wir e A E B Remove center , silver -colored terminal block scr ew (B). Remove neutral ground wir e (E) from external ground conductor screw (A). E B C Connect neutral ground wir e and neutral wire 2.
13 V enting Requirements W ARNING Fire Hazar d Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to follow these instructions can result in death or re. WARNING: T o r educe the risk of re, this dryer MUST BE EXHAUSTED OUTDOORS.
14 Plan V ent System Recommended exhaust installations T ypical installations vent the dryer from the r ear of the dryer . Other installations are possible. B B C D E F G H I A A. Dryer B. Elbow C. Wall D. Exhaust hood E. Clamps F . Rigid metal or exible metal vent G.
15 Install V ent System 12" min. (305 mm) 12" min. (305 mm) Install exhaust hood 1. Install exhaust hood and use caulking compound to seal exterior wall opening around exhaust hood. Connect vent to exhaust hood 2. V ent must t over the exhaust hood.
16 Level Dryer Level Dryer 1. Not Level LEVEL Not Level Check levelness of dryer from side to side. Repeat fr om front to back. NOTE: The dryer must be level for the moisture sensing system to operate correctly . Move dryer to nal location 2. Move dryer to nal location.
17 Reverse Door Swing (Optional) Place towel on dryer 1. Place towel on top of dryer to avoid damaging the surface. Lift door until top screws in dryer cabinet ar e in large part of hinge slot. Pull door forward of f screws. Set door (handle side up) on top of dryer .
18 Remove and transfer plugs 9. Remove the 4 screws that attach 2 plugs on the left side. T ransfer plugs to opposite side using the same 4 screws. Attach door hinges 8. Reattach door hinges to dryer door so that the lar ger hole is at the bottom of the hinge.
19 Notes.
20 W10096988A W10306460A-SP © 2010 Whirlpool Corporation. 2/10 All rights reserved Printed in U.S.A. ® Registered T rademark/TM T rademark of Whirlpool, U.
デバイスMaytag W10306460A-SPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Maytag W10306460A-SPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMaytag W10306460A-SPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Maytag W10306460A-SPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Maytag W10306460A-SPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Maytag W10306460A-SPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMaytag W10306460A-SPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Maytag W10306460A-SPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMaytag W10306460A-SPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。