Metrologic InstrumentsメーカーMS6520の使用説明書/サービス説明書
ページ先へ移動 of 48
METROLOGIC INSTRUMENTS, INC. IS6520/MS6520 Cubit™ Series Omnidirectional Bar Code Scanner Installation and User’s Guide.
.
ii L OCATIONS North America Headquarters Metrologic Instruments, Inc. Customer Service: 1-800-ID-METRO 90 Coles Road Tel: 856-228-8100 Blackwood, NJ 08012-4683 Fax: 856- 228-6673 Email: info@me trologic.com Website: www.metrologic.com Germany Metrologic Instruments GmbH Tel: 49-89-89019-0 Dornierstrasse 2 Fax: 49-89-89019-200 82178 Puchheim b.
iii Printed in USA March 2000.
iv T ABLE OF C ONTENTS Introduction ...................................................................................................... 1 Scanner and Accessories ................................................................................. 2 Quick Start .
v T ABLE OF C ONTENTS Appendix C Scanner Pinout Connections ....................................................................... 32 Cable Connector Configurations ................................................................. 32 Appendix D Warranty and Disclaimer .
* Printer Note : Leave page blank.
1 I NTRODUCTION Metrologic's Cubit™ is a compact, omnidirectional bar code scanner that can be used as a presentation scanner or as the scanning component in Original Equipment Manufacturer (OEM) applications. Incorporating the latest in scanning technology Cubit™ can scan and decode all standard bar codes in any orientation.
2 S CANNER AND A CCESSORIES The following is a list of the parts included in the IS6520/MS6520 Kit. • Cubit™ IS6520/MS6520 - Omnidirectional Scanning Engine • PowerLink Power Supply - AC to DC Power Transformer. Regulated 5.2 VDC @ 650 mA output.
3 Q UICK S TART 1. Connect the 10-pin RJ45 male connector into the jack on the Cubit™ IS6520/MS6520. You will hear a ‘click’ when the connection is made. 2. Connect the L-shaped plug of the power supply into the power jack on the PowerLink cable.
4 • • Ž • ‘ Œ I NSTALLING THE IS6520-41/MS6520-41 TO THE H OST S YSTEM 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector into the jack on the Cubit™ IS6520/MS6520. You will hear a ‘click’ when the connection is made.
5 • • Ž • ‘ Œ “ ’ & I NSTALLING THE IS6520-47/MS6520-47 TO THE PC 1. Turn off the PC. 2. Connect the 10-pin RJ45 male connector into the jack on the Cubit™ IS6520/MS6520. You will hear a ‘click’ when the connection is made. 3. Connect the L-shaped plug of the power supply into the power jack on the PowerLink cable.
6 To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.
7 D ISCONNECTING THE P OWER L INK C ABLES FROM THE S CANNER Before removing the cable from the scanner, Metrologic recommends that the power on the host system is off and the power supply has been disconnected from the PowerLink cable. 1. Locate the small ‘pin-hole’ on the back of the scanner.
8 S CANNER P ARTS A. Speaker Serves as an audible indicator. B. Green & Red LEDs During normal operation, the green LED is on. This indicates that the laser is on and the unit is ready to scan. On a successful read of a bar code, the red LED will turn on.
9 M OUNTING H OLES Each IS6520/MS6520 Cubit™ is equipped with three threaded mounting holes located on the back of the scanner. The following diagram shows the exact location of each mounting hole. The mounting holes are 6 millimeters deep and are threaded for use with 3 millimeter screws.
10 A UDIBLE I NDICATORS When the IS6520/MS6520 scanner is in operation, it provides audible feedback. These sounds indicate the status of the scanner . Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). To change the tone, refer to the MetroSelect ® Programming Guide MLPN 2407.
11 F AILURE M ODES Flashing Green and One Razzberry Tone This indicates the scanner has experienced a laser subsystem failure. Return the unit for repair at an authorized service center. Flashing Green and Red and Two Razzberry Tones This indicates the scanner has experienced a motor failure.
12 V ISUAL I NDICATORS There is a red LED and a green LED on IS6520/MS6520. When the scanner is on, the flashing or stationary, activity of the LEDs indicates the status of the current scan and the scanner. No Red or Green LED The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer.
13 P ROGRAMMING M ODES The IS6520/MS6520 Cubit™ has 3 modes of programming. Bar Codes: Cubit™ can be configured by scanning the bar codes located in the MetroSelect ® Configuration Guide (MLPN 2407). Please refer to this guide for instructions. This manual can be downloaded for FREE from Metrologic’s website (www.
14 P ROGRAMMING M ODES ( CONTINUED ) 6. To enter serial program mode, send the following command [stx]999999[etx]. 7. To exit serial program mode, send the following command [stx]999999[etx], the scanner will respond with an [ack] and a long beep.
15 P ROGRAMMING M ODES ( CONTINUED ) EXAMPLE #3 : The following example shows the events that occur when an invalid bar code is sent. This sample will load the factory default settings and then set the baud rate to 19200.
16.
17 L ABELS Each scanner has a label on the back of the unit. This label has the model number, date of manufacture, serial number, CE and caution information. The following is an example of this label: M AINTENANCE Smudges and dirt can interfere with the proper scanning of a bar code.
18 O PTIMAL L OW AND C LOSE D EPTH OF F IELD Minimum Bar Code Element Width A B C D E F G H J K mm - .15 - .17 - - .25 .33 .53 - mils - 5.7 - 6.8 - - 10 13 21 - Note: The same depth of field is achieved when programming Cubit™ for either Optimal Low Depth of Field or Close Depth of Field.
19 O PTIMAL H IGH AND N ORMAL D EPTH OF F IELD Minimum Bar Code Element Width A B C D E F G H J K mm - .15 - .17 - - .25 .33 .53 - mils - 5.7 - 6.8 - - 10 13 21 - Note: The same depth of field is achieved when programming Cubit™ for either Optimal High Depth of Field or Normal Depth of Field.
20 F AR D EPTH OF F IELD Minimum Bar Code Element Width A B C D E F G H J K mm - .15 - .17 - - .25 .33 .53 - mils - 5.7 - 6.8 - - 10 13 21 - 0 25 50 75 100 125 150 175 200 250 225 DISTANCE: SCANNER FA.
21 T ROUBLESHOOTING G UIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-ME'I'RO or 1-800-436-3876 to preserve the limited warranty terms.
22 T ROUBLESHOOTING G UIDE ( CONTINUED ) All Interfaces IS6520/MS6520 Series Troubleshooting Guide (continued) SYMPTOMS POSSIBLE CAUSE(S) SOLUTION The unit powers up, but does not scan and/or beep Beeper disabled.
23 T ROUBLESHOOTING G UIDE ( CONTINUED ) All Interfaces IS6520/MS6520 Series Troubleshooting Guide (continued) SYMPTOMS POSSIBLE CAUSE(S) SOLUTION Scanner beep s at some bar codes and NOT for others of the same bar code symbology The print quality of the bar code is suspect Check print mode.
24 T ROUBLESHOOTING G UIDE ( CONTINUED ) RS-232 only IS6520/MS6520 Series Troubleshooting Guide (continued) SYMPTOMS POSSIBLE CAUSE(S) SOLUTION Powers up OK and scans OK but does not communicate prope.
25 A PPENDIX A Design Specifications Operational Light Source : VLD 650 ± 10 nm, 0.681 milliwatts (PEAK) Depth of Field : 0 mm to 176 mm (0” to 7”) for 0.33 mm (13 mil) bar code at default setting ( programmable) Scan Speed : 1000 scan lines /second Scan Pattern : 5 fields of 4 parallel lines (omnidirectional) Scan Lines: 20 Min Bar Width : 0.
26 A PPENDIX A ( CONTINUED ) Design Specifications Electrical Power: 1.0 W Input Voltage : 5 VDC ± 0.25 V Operating Current : 200 mA typical @5VDC DC Transformer s : Class 2 ; 5.
27 A PPENDIX B Default Settings Many functions of the scanner can be "programmed" - that is, enabled or disabled. The scanner is shipped from the factory programmed to a set of default conditions. The default parameter of the scanner has an asterisk (*) in the charts on the following pages.
28 A PPENDIX B ( CONTINUED ) Parameter Default RS-232* Light Pen DTS/NIXDORF * NCR F NCR S Poll Light Pen Source a Beeper Tone Normal a a Beep/ Transmit Sequence Before Transmit a a Communication Timeout None a a Razzberry Tone on Timeout a a Three Beeps on Timeout a a No Beeps on Timeout * a a Enter Power Save Mode 10 mins.
29 A PPENDIX B ( CONTINUED ) Parameter Default RS-232* Light Pen Transmit UPC-A Manufacturer ID# * a a Transmit UPC-A Item ID# * a a Transmit Codabar Start/Stop Characters a CLSI Editing a Transmit Mo.
30 Character RTS/CTS * a.
31 A PPENDIX B ( CONTINUED ) Parameter Default RS-232* Light Pen Message RTS/CTS a XON/XOFF Handshaking a ACK/NA K a Two Digit Suppliments a as code 39 Five Digit Suppliments a as code 39 Bookland a a.
32 1 10 A PPENDIX C Scanner Pinout Connections The IS6520/MS6520 scanner interfaces terminate to a 10-pin modular jack. The serial # label indicates the interface enabled when the scanner is shipped from the factory.
33 A PPENDIX C ( CONTINUED ) Keyboard Wedge Powerlink and Adapter Cable (MLPN 54-54008) The Keyboard Wedge PowerLink cable is terminated with a 5-pin DIN female connector on one end, and a 6-pin mini DIN male on the other.
34 6 No Connect 6 No Connect.
35 A PPENDIX D Warranty and Disclaimer Limited Warranty The IS6520/MS6520 Cubit ™ scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The IS6520/MS6520 Cubit ™ scanners have a two (2) year limited warranty from the date of manufacture.
36 FAX: 856-228-6673.
37 A PPENDIX E Notices Notice This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
38 A PPENDIX E ( CONTINUED ) European Standard Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Funkstöreigenschaften nach EN 55022:1998 Warnung! Dies ist eine Einrichtung der Klasse A.
39 A PPENDIX F Patents “Patent Information This METROLOGIC product may be covered by one or more of the following U.S. Patents: U.S. Patent No.; 4,960,985; 5,081,342; 5,216,232; 5,260,553; 5,340,971.
40 I NDEX A AC input/outlet ........... 3, 4, 5, 6, 30 Accessories ................................. 3 Approvals ...................... 16, 33, 34 Assignments Pin ......................................... 30 Audible ...................................
36 I NDEX P Parts ........................................ 3, 8 PC ............................................... 5 Port ....................................... 6, 23 Power supply ................. iv, 3, 6, 30 Powerlink ......................... 3, 4, 5, 7 Programming guide .
デバイスMetrologic Instruments MS6520の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Metrologic Instruments MS6520をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMetrologic Instruments MS6520の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Metrologic Instruments MS6520の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Metrologic Instruments MS6520で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Metrologic Instruments MS6520を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMetrologic Instruments MS6520の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Metrologic Instruments MS6520に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMetrologic Instruments MS6520デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。