Keep these important operating instructions. Check www .meyerso und.com for updates. OPERATING INSTRUCTIONS INDUSTRIAL SERIES MM-4XP Miniatur e Loudspeaker MPS-488 Power Supply.
ii DECLARATION OF CONFORMITY ACCORDIN G TO ISO/IEC GUIDE 22 AND EN 45014 Manufacturer’ s Name: Meyer Sound Laboratories Inc. Manufacturer’ s Address: 2832 San Pablo Avenue Berkeley , CA 94702-2204.
iii SYMBOLS USED These symbols indicate important safety or operating featu res in this booklet and on the chassis: IMPORTANT SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all inst ructions.
iv SAFETY SUMMARY English ■ T o reduce the risk of electric shock, dis- connect the loudspeaker from the AC mains before installing audio cable. Reconnect the power cord only after making all signal connections. ■ Connect the loudspeaker to a tw o-pole, three-wir e grounding mains receptacle.
v CONTENTS Chapter 1: Introduction 7 How to Use This Manual 7 the MM-4XP Miniature Loudspeaker 7 Chapter 2: The MPS-488 Power Supply 9 The MPS-488 Front Panel 9 The MPS-488 Rear Panel 9 MPS-488 Curren.
CONTENTS vi.
7 CHAPTER 1: INTR ODUCTION HOW TO USE THIS MANUAL Make sure to r ead these operating instructions in their entirety befor e configuring a loudspeaker system with MM-4XPs.
CHAPTER 1: INTRODUCTION 8 MM-4XP loudspeaker systems requir e an MPS-488 exter nal power supply . The single-space 19-inch rack unit receives eight channels of balanced audio fr om its XLR female inputs and routes the au dio, along with 48 V of DC power , to its eight Channel Outputs.
9 CHAPTER 2: THE MPS-488 POWER SUPPLY The MPS-488 power supply was designed to d eliver DC power and balanced audio to up to eight MM-4XP lo ud- speakers. The MPS-488 is a switched-mode regulat ed power supply that occupies one space in a standard 19-inch rack.
CHAPTER 2: THE MPS-488 POWER SUPPLY 10 Channel Inputs Up to eight channels of balanced audio ar e received via the MPS-488’ s eight Channel Inputs. The inputs are equipped with XLR female connectors (pin 1, gr ound; pin 2, signal positive; pin 3, signal negative) and have an input imped- ance of 10 kOhms.
MM-4XP OPERATING INSTRUCTIONS 11 ■ When Link switches 1 and 3 are on and Link switch 2 is off, Cha nnel Input 1 is routed to Channel Outputs 1–2, and Channel Input 3 is r outed to Channel Outputs 3–4.
CHAPTER 2: THE MPS-488 POWER SUPPLY 12 Channel Outputs The eight Channel Outputs deliver DC power (48 V DC) and balanced audio to up to eight loudspeakers. Each Channel Output can drive one MM-4XP loudspeaker and is equipped with either Phoenix 5-pin male connectors (on the MPS-488 P model) or EN3 5-pin male connectors (on the MPS-488 E model).
MM-4XP OPERATING INSTRUCTIONS 13 ■ Burst Curr ent — The maximum rms current during a period of around one second. The Burst Current is used as a rating for magnetic breakers.
CHAPTER 2: THE MPS-488 POWER SUPPLY 14.
15 CHAPTER 3: THE MM-4XP LOUDSPEAKER THE MM-4XP CONNECTOR The MM-4XP r eceives DC power and balanced audio fr om a EN3 5-pin male connector on its r ear panel. The connector’ s five pins include two for DC power (negative and positive) and thr ee for balanced audio (shield, negative, and po sitive).
CHAPTER 3: THE MM-4XP LOUDSPEAKER 16 MM-4XP Current Draw and Cable Require- ments Each MM-4XP loudspeaker draws a maximum curr ent of 0.7 A rms and 2.2 A peak fr om the 48 V DC output of the MPS-488. The current draw for the MM-4XP is dynamic and fluctuates as operating levels change.
MM-4XP OPERATING INSTRUCTIONS 17 The MM-4XP performs within its acoustical specifications at normal temperatures when the MM-4XP LED is g reen, or if the LED turns yellow for two seconds or less and then turns green for a t least one second.
CHAPTER 3: THE MM-4XP LOUDSPEAKER 18 CAUTION: Make sure the MM-4XP loud- speaker cables are wir ed correctly . For details on assembling loudspeaker cables, see Appendix C, “MM-4XP Cable Assembly .
19 CHAPTER 4: MOUNTING THE MM-4XP IMPORTANT SAFETY CONSIDERATIONS When installing Meyer Sound loudspeakers, the following precautions should always be o bserved: ■ All Meyer Sound products must be u sed in accordance with local, state, federal, and industry r egulations.
CHAPTER 4: MOUNTING THE MM-4XP 20.
21 APPENDIX A: SPECIFICATIONS MM-4XP SPECIFICATIONS Operating Frequency Range 120 Hz – 18 kHz Note: Recommended maximum operating frequency range. Response depe nds on loading conditions and room acoustics. Frequency Response 160 Hz – 16 kHz ±4 dB Note: Measured free-fi eld with pink noise at 1 meter , 1/3rd octave resolution.
APPENDIX A: SPECIFICATIONS 22 MPS-488 SPECIFICATIONS Audio Inputs 8 channels of XLR fe male connectors with Link sw itches to route to outputs Outputs 8 channels of Phoenix 5-pin male co nnectors or EN3 5-pin fe male connectors (3 pins for balanced audio, 2 pins for DC power) Output V oltage 8 channels of 48 V DC (2 .
23 APPENDIX B: MM-4XP ACCESSORIES MM-4XP ACCESSORIES The following MM-4XP accessories ar e available from Meyer Sound. MM-4XP CABLE CONNECTORS AND ADAPTERS The following MM-4XP cable connectors and adapters ar e available from Meyer Sound. MM-4XP Accessories Part Number Accessory Not es 09.
APPENDIX B: MM-4XP ACCESSORIES 24 MM-4XP CABLES The following MM-4XP cables are available f rom Meyer Sound. NOTE: All MM-4XP loudspeaker cables and bulk cable use Belde n 1502R (regular) or Belden 1502P (plenum) cable.
25 APPENDIX C: MM-4XP CABLE AS SEMBLY ASSEMBLING EN3-TO-PHOENIX LOUDSPEAKER CABLES T o connect the MM-4XP loudspeaker directly to t he MPS-488 P power supply , you need an EN3 5-pin female to Phoenix 5-pin female cable. The following pr ocedure documents how to a ssemble this cable.
APPENDIX C: MM-4XP CABLE ASSEMBLY 26 4. Disassemble the EN3 5-pin female connector and feed one end of the cable through the boot, cable clamp housing, and coupling ring. 5. If the EN3 end of the cable has not been stripped, strip the outer shielding 1” and then strip the black, red, b lue, and white wires .
MM-4XP OPERATING INSTRUCTIONS 27 ASSEMBLING EN3-TO-EN3 LOUDSPEAKER CABLES T o connect the MM-4XP loudspeaker directly to t he MPS-488 E power supply , you need an EN3 5-pin female to EN3 5-pin male cable. The following pr ocedure documents how to assemble t his cable.
APPENDIX C: MM-4XP CABLE ASSEMBLY 28 3. Solder the five exposed conductors to the five pins on the EN3 cor d connector using the following wiring scheme. 4. Reassemble the EN3 5-pin male connector: ■ Align the coupling ring’ s side notches with the cord connector’ s side notches and slide the couple ring onto the cord connector .
.
.
.
Meyer Sound Labo ratories In c. 2832 San Pablo Avenue Berkeley, CA 94702 www.meyersound.com T: +1 510 486.1166 F: +1 510 486.8356 © 2007 Meyer Sound Labo ratories In c.
デバイスMeyer Sound MPS-488の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Meyer Sound MPS-488をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMeyer Sound MPS-488の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Meyer Sound MPS-488の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Meyer Sound MPS-488で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Meyer Sound MPS-488を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMeyer Sound MPS-488の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Meyer Sound MPS-488に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMeyer Sound MPS-488デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。