Operating and Installation Instructions Ventilation System To prevent accidents and machine damage, read these instructions before installation or use.
IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Description of functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Guide to the Ventilation System . . . .
READ AND SAVE THESE INSTRUCTIONS Keep these instructions in a safe place and pass them on to any future user. Read these instructions carefully before installing or using the Ventilation System. ~ This appliance is intended for residential use only. Use the appliance only for its intended purpose.
~ d) Before connecting the appliance to the power supply make sure that the voltage and frequency listed on the data plate correspond with the household electrical supply. This data must correspond to prevent appliance damage. If in doubt consult a qualified electrician.
, WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING * : ~ a) SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray then turn off the burner. BE CAREFUL TO PREVENT BURNS . If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
Installation , WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: ~ a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
The ventilation system offers the following modes of operation: Air extraction with internal blower A blower that is integrated into the ventilation system removes any cooking vapors. The air is guided though the baffle filters and cleaned. Then the air is directed outside.
Guide to the Ventilation System 8.
a Duct cover in four different heights (DRDC) b Vents for recirculated air (with the DRUU recirculation kit for air recirculation mode) c Ventilation hood d OdorFree charcoal filter (behind baffle fil.
The following combinations of appliances are possible: Air Extraction with Internal Blower Air Extraction with External Blower Air Recirculation Duct Cover Range Insert DAR 1120 30" Blower DRIB X.
Turning the light on/off The overhead LED light and the blower can be turned on and off separately. Turning the blower on/off ^ Turn the blower switch to "1" to turn the blower on and to "0" to turn the blower off.
, WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before cleaning or servicing the hood, disconnect it from the power supply, see "Important Safety Instructions". Cleaning the casing Never use abrasive cleaners, scouring pads, steel wool or caustic (oven) cleaners on the hood.
Stainless steel colored controls These controls may become dis - colored or damaged if not cleaned regularly. Do not use a stainless steel cleaner on these controls.
Cleaning the baffle filters ^ In a dishwasher: place the filter vertically in the lower basket, making sure that the spray arm is not blocked. Use a wash program with a max. temperature of 150°F (65°C). In a Miele dishwasher use either the "Normal" or "Grates and Filters" pro- gram.
OdorFree charcoal filters A recirculation kit is required to use the ventilation system in air recirculation mode. DA 1220: DRUU 30 DA 1230: DRUU 36 For recirculation mode the OdorFree charcoal filters must be used in addition to the baffle filters. The OdorFree charcoal filters are designed to absorb cooking odors.
Repairs In the event of a fault which you cannot easily fix yourself, please contact the Miele Technical Service Department. ^ When contacting the Technical Ser - vice Department, please quote the model and serial number of your appliance. These are shown on the data plate.
Installation Instructions Read these instructions and the "Important Safety Instructions" before installing this ventilation system. The installation steps are described in the enclosed "Installation Diagram". Leave these instructions with the appliance for the consumer/user.
Disposal of packing material The cardboard box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Please recycle. , DANGER Ensure that any plastic wrappings, bags, etc., are disposed of safely and kept out of the reach of babies and young children.
Appliance dimensions 19.
Appliance dimensions 20.
a The hood with exhaust collar is only used in air extraction mode with an internal or external blower. b Installation area; Wall/ceiling area respectively for vent hole and outlet installation. For recirculation mode only the outlet installation is required.
a The hood with exhaust collar is only used in air extraction mode with an internal or external blower. b Installation area; Wall/ceiling area respectively for vent hole and outlet installation. For recirculation mode only the outlet installation is required.
a Installation area; Wall/ceiling area respectively for vent hole and outlet installation. Appliance dimensions 23.
Distance between cooktop and hood (S) Do not install this exhaust hood over cooktops burning solid fuel. Observe the cooktop manufacturer's instructions when determining the distance between cooktop and lower edge of the hood. Unless the instructions require a greater distance, the adjacent minimum safety distances apply for Miele cooktops.
Distance between cooktop and hood (S) Miele Range hood DAR 1120, DAR 1220 (30") DAR 1130, DAR 1230 (36") DAR 1150, DAR 1250 (48") Internal / External blowers DRIB/DREB XL (700 cfm) DRIB.
The majority of the weight of the installed ventilation system will be supported by the retaining plate. It must be firmly attached to the stud framing behind the drywall. If studs are not available in the required locations, a plywood backing (min. ½" (13 mm) thick) spanning at least two studs must be installed.
Before installation read the information in the "Dimensions" and "Important Safety Instruction" chapters. Under certain conditions, there is a danger of poisonous fumes by when the ventilation system and a furnace drawing interior air run at the same time.
, WARNING Danger of toxic fumes. Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. To reduce the risk of fire and to properly exhaust air, the exhaust gases extracted by the hood should be vented outside of the building only.
– If the exhaust is ducted into an inactive flue, the air must be expelled parallel to the flow direction of the flue. Never connect an exhaust hood to an active chimney, dryer vent, flue, or room venting ductwork. Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent flue.
, WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: All electrical work should be performed by a qualified electrician in strict accordance with national regulations (for USA: ANSI-NFPA 70) and local safety regulations.
Total connected load DAR 1120, DAR 1220 with DRIB XL or DREB XL ......6 1 9W DAR 1130, DAR 1230 with DRIB XL or DREB XL ......6 2 1W DAR 1130, DAR 1230 with DRIB XXL or DREB XXL ....8 0 6W DAR 1150, DAR 1250 with DRIB XXL or DREB XXL ....8 0 8W Overhead lights DAR 1120, DAR 1220 .
32.
33.
34.
35.
M.-Nr. 09 824 260 / 01 en - US, CA DAR 1120, 1130, 1150 DAR 1220, 1230, 1250.
デバイスMiele 09 824 260の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Miele 09 824 260をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMiele 09 824 260の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Miele 09 824 260の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Miele 09 824 260で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Miele 09 824 260を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMiele 09 824 260の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Miele 09 824 260に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMiele 09 824 260デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。