Mieleメーカーda 186の使用説明書/サービス説明書
ページ先へ移動 of 28
Operating and installation instructions Cooker hood DA 186 To avoid the risk of accidents or damage to this appliance, it is essential to read these instructions before it is installed and used for the first time.
Caring for the environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Warning and Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Modes of operation . . . . . .
Disposal of the packing material The transport and protective packing has been selected from materials which are environmentally friendly for disposal, and should be recycled. Packaging e.g. cling film, polystyrene and plastic wrappings must be kept out of the reach of babies and young children.
This appliance complies with all relevant local and national safety requirements. Inappropriate use can, however, lead to personal injury and damage to property. To avoid the risk of accidents and damage to the appliance, please read these instructions carefully before using it for the first time.
Technical safety ~ Before installation, check the cooker hood for visible signs of damage. Under no circumstances should you use a damaged appliance. A damaged appliance is dangerous.
~ Do not connect the appliance to the mains electricity supply by a multi-socket unit or an extension lead. These do not guarantee the required safety of the appliance (e.g. danger of overheating). ~ This appliance must not be used in a non-stationary location (e.
In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the cooker hood and the heater are in operation simultaneously, an underpressure in the room of 0.04 mbar (4 pa) is the maximum permissible.
~ Do not use the cooker hood without the filters in place. This way you will avoid the risk of grease and dirt getting into the appliance and hindering its smooth operation. ~ The filters should be regularly cleaned or changed as appropriate. Saturated filters are a fire hazard.
The cooker hood works with . . . air extraction: The air is drawn in and cleaned by the grease filters and directed outside. If the on-site ventilation system does not have a non-return flap , the non-return flap supplied must be fitted. This flap is closed when the cooker hood is switched off.
Guide to the appliance / Operation 10.
a Recirculation grille (only for recirculation mode) b Exhaust connection c Adjustable bracket d Vapour canopy to which a furniture door front is fitted e Charcoal filter (extra accessory available to order for recirculation mode) f Hob lighting g Grease filters h Control panel Operation To switch on the fan ^ Open the vapour canopy.
A range of Miele branded cleaning and conditioning products is available to order from Miele (see back page for details) or via the internet at www.miele-shop.com. , Before carrying out any cleaning or maintenance work, disconnect the cooker hood from the mains supply.
Grease filters The re-usable metal grease filters in the appliance remove solid particles (grease, dust, etc.) from the kitchen vapours, preventing soiling of the cooker hood. They should be cleaned at least every 3-4 weeks to avoid grease sticking hard to them.
Charcoal filters If the cooker hood is being used on recirculation mode, two DKF 14-1 charcoal filters must be fitted behind the grease filters. ^ Open the vapour canopy ^ Remove the grease filters. ^ Unwrap the charcoal filters. ^ Position the charcoal filters on either side of the fan as shown, and twist securely into place.
Changing a halogen lamp , Before any cleaning or maintenance work, disconnect the cooker hood from the mains supply. , Exercise caution when changing halogen lamps.
In the event of a fault which you cannot correct yourself, or if the appliance is under guarantee, please contact: – your Miele Dealer or – the Miele Service Department (see back cover for contact details).
* Furniture panel dimensions Connection for air extraction C 150 mm, or C 120 mm with reducing collar. Safety distance between hob and cooker hood The distance betwen the top of the cooker/hob and the bottom of the cooker hood must measure at least 650 mm , unless a greater distance is specified by the manufacturer.
Before installation, it is important to read the information given on the following pages as well as the Warning and Safety instructions at the beginning of this booklet.
Depth adjustment ^ The depth of the unit "T" can be adjusted from 275 to 360 mm by means of the adjustable brackets. ^ Slightly loosen the screws on the brackets. ^ Then pull the brackets out until you achieve the required depth "T".
^ The recirculation grille must be removed when the hood is used in extraction mode. ^ Hang the cooker hood in position using the adjustable brackets. ^ Position the vapour canopy with the furniture door front fitted, and close it. The movement of the vapour canopy can be adjusted if necessary, for instance where a heavy furniture door is fitted.
Height adjustment ^ Using the screws at the back of the adjustable brackets, align the cooker hood height with that of neighbouring units. Turn the screw – anti-clockwise : to raise the appliance. – clockwise : to lower the appliance. ^ If necessary adjust the depth again.
With air extraction: If the on-site ventilation system does not have a non-return flap, one of the two non-return flaps supplied (for C 150 mm or C 120 mm ducting) must be fitted. –I f C 150 mm ducting is being used, the non-return flap should be fitted onto the exhaust connection.
All electrical work should be undertaken by a suitably qualified and competent person in strict accordance with current national and local safety regulations (BS 7671 in the UK). Installation, repairs and other work by unqualified persons could be dangerous, for which the manufacturer cannot be held liable.
Important: To avoid the danger of toxic fumes, please observe the Warning and Safety instructions. This is especially crucial when using the cooker hood at the same time as another heating appliance which relies on air from the same room. The cooker hood should be installed according to local and national building regulations.
Total connected load ..........1 7 5W Fan motor .................1 3 5W Hob lighting ..............2x2 0W Voltage ................. A C2 3 0V Frequency .................~5 0H z Fuse rating (UK) ................5A Electrical cable length .........1 . 8m Fan performance Extraction power according to EN 61591 Extraction system C 150 mm: Level I .
26.
27.
Alteration rights reserved / 3011 M.-Nr. 07 623 170 / 03.
デバイスMiele da 186の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Miele da 186をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMiele da 186の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Miele da 186の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Miele da 186で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Miele da 186を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMiele da 186の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Miele da 186に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMiele da 186デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。