Operating and Installation Instructions Ventilation System DA 6590 W DA 6520 W To prevent accidents and appliance damage, read these instructions before installation or use.
IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Description of functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Guide to the ventilation system . . . .
READ AND SAVE THESE INSTRUCTIONS Keep these instructions in a safe place and pass them on to any future user. Read these instructions carefully before installing or using the Ventilation System. ~ This appliance is intended for residential use only. Use the appliance only for its intended purpose.
~ d) Before connecting the appliance to the power supply make sure that the voltage and frequency listed on the data plate correspond with the household electrical supply. This data must correspond to prevent appliance damage. If in doubt consult a qualified electrician.
, WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING * : ~ a) SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray then turn off the burner. BE CAREFUL TO PREVENT BURNS . If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
Installation , WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: ~ a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
The ventilation system can be operated Air extraction The air is drawn in and cleaned by the grease filters and directed outside. The hood comes equipped with a non-return flap . This flap automatically closes when the hood is turned off so that no exchange of outside air and room air can occur.
Guide to the ventilation system 8.
a Chimney extension b Chimney c Canopy d Control panel e Grease filter f Glass or stainless steel panels Optional accessories DRP 6590 W glass (3 elements) DRP 6590 W stainless steel (3 elements) g Re.
Turning the fan on K ^ Press the On/Off button K . The fan turns on at level 2 . The K symbol and power level 2 indicators light up. Selecting the power level ^ Use the " – / + " controls to select the desired power level.
Delayed shut down 5 ¢ 15 For both air extraction and recirculation, it is recommended that run the fan for several minutes after cooking is completed. This helps clear the kitchen air of any remaining vapors and odors. The Delayed Shut Down feature can be selected to turn the fan off automatically after a preselected length of time.
Automatic safety shut-off The fan will turn automatically off 10 hours of use. The lighting however will remain on. ^ Press the On/Off button K to turn the fan back on again.
Activating/changing the odor-free filter timer (in recirculation mode) The odor-free filter is necessary for recirculation mode. The odor-free filter timer is not pre-set . The timer may be set to suit your cooking habits. ^ Press the On/Off button K to turn the fan off ^ Press + and the filter button — at the same time.
, WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before cleaning or servicing the hood, disconnect it from the power supply, see "Important Safety Instructions". , The halogen bulbs are very hot when in use.
Special instructions for glass surfaces ^ Glass surfaces should be cleaned with a normal glass cleaner. Stainless steel colored controls These controls may become dis - colored or damaged if not cleaned regularly. Do not use a stainless steel cleaner on these controls.
^ Open the grease filter lock, lower the grease filter slightly, unhook it at the back, and take it out. Support the grease filter so that it does not fall and damage the cooktop. Cleaning the panels by hand ^ Follow the instructions under "Cleaning the casing".
^ When reinstalling the grease filters, make sure that the locking clips are facing down. ^ If the filters are incorrectly installed, insert a small screwdriver into the slit along its edge to disengage them from the casing. ^ Hook the panels onto the support ledge.
Installing / replacing the odor-free filter In recirculation mode, an odor-free filter must be used in addition to the grease filters. It is designed to absorb cooking odors. It is installed in the canopy above the grease filters. Replacement active charcoal filters can be ordered from Miele.
Changing the light bulbs , WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before changing the light bulbs, disconnect the hood from the power supply, see "Important Safety Instructions". When in use halogen bulbs become extremely hot, and can burn your hands.
Repairs In the event of a fault which you cannot easily fix yourself, please contact the Miele Technical Service Department. ^ When contacting the Technical Service Department, please quote the model and serial number of your appliance. These are shown on the data plate which is visible when the grease filters are removed.
Installation Instructions Read these instructions and the "Important Safety Instructions" before installing this ventilation system. The installation steps are described in the enclosed "Installation Diagram". Leave these instructions with the appliance for the consumer/user.
22.
Disposal of packing material The cardboard box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Please recycle. , DANGER Ensure that any plastic wrappings, bags, etc., are disposed of safely and kept out of the reach of babies and young children.
Drawing is not to scale. Appliance dimensions 24.
a Air extraction mode b Recirculation mode c Recirculation vent positioned at the top (only for the DA 6590 W in recirculation mode) d , e Installation area; For recirculation mode only d . Wall/ceiling area respectively for vent hole and outlet installation.
Distance between cooktop and hood (S) Do not install this exhaust hood over cooktops burning solid fuel. Provided a larger distance is not given by the manufacturer of the cooktop, follow the minimum .
Drilling diagram To prepare a backing plate, the spacings for the 5 mm screws need to be drilled as shown. If the ventilation hood will be mounted directly to the wall, follow the additional instructions given in the included "Installation diagram".
The majority of the weight of the installed ventilation system will be supported by the lower retaining plate. It must be firmly attached to the stud framing behind the drywall. If studs are not available in the required locations, a plywood backing (min.
Before installation read the information in the "Dimensions" and "Important Safety Instruction" chapters. Under certain conditions, there is a danger of poisonous fumes by when the ventilation system and a furnace drawing interior air run at the same time.
Installation material Installation 30.
a 3 protective shields to prevent scratches to the chimney during installation. b 1 vent collar for use with 6" (150 mm) exhaust ducting. c 1 vent pipe adapter for use with 5" (125 mm) exhaust ducting. d Telescopic retaining plate to secure the ventilation hood to the wall.
, WARNING Danger of toxic fumes. Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. To reduce the risk of fire and to properly exhaust air, the exhaust gases extracted by the hood should be vented outside of the building only.
– If the exhaust is ducted into an inactive flue, the air must be expelled parallel to the flow direction of the flue. Never connect an exhaust hood to an active chimney, dryer vent, flue, or room venting ductwork. Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent flue.
Reducing Collar (optional accessory) If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed. It reduces the air flow to less than 400 CFM. Check local building codes for max.
, WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: All electrical work should be performed by a qualified electrician in strict accordance with national regulations (for USA: ANSI-NFPA 70) and local safety regulations.
Total connected load * ........4 1 0W – Fan motor * ................3 5 0W – Overhead light ...........3x2 0W Voltage ................. 1 2 0VA C Frequency .................. 6 0H z Fuse rating ...................1 5A Length of the power cord ....
37.
38.
39.
Alteration rights reserved / 5012 INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOST CURRENT PRODUCT SPECIFICATIONS, TECHNICAL & WARRANTY INFORMATION.
デバイスMiele DA 6520 Wの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Miele DA 6520 Wをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMiele DA 6520 Wの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Miele DA 6520 Wの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Miele DA 6520 Wで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Miele DA 6520 Wを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMiele DA 6520 Wの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Miele DA 6520 Wに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMiele DA 6520 Wデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。