Installation instructions for the T 9820 Gas Dryer The T 9820 gas dryer is only approved for use in the USA and Canada. It is not approved for use in Mexico. To prevent accidents and machine damage read these instructions before installation or use. M.
2.
3 , W ARNING For y our safety the inf ormation in this manual must be f ollo wed to minimize the risk of fire or explosion or to pre vent pr operty damage , personal injury or death. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Stand ......................
Installation and connection When using your gas appliance follow basic safety precautions including the following: ~ Installation, repair and maintenance work should be performed by a qualified installer, service agency or the gas supplier. Work by unqualified persons could be dangerous and could void the warranty.
~ The dryer exhaust must not be connected to a chimney, fireplace ducting, a combustion appliance vent flue, a wall, ceiling or concealed space of a building. ~ Do not install the machine in rooms where temperatures below freezing may occur. ~ Proper installation is the responsibility of the installer.
Front view a Exhaust connection b Power cord with plug c Control panel d Door e Four height adjustable screw feet Stand A dryer stand, with drawer, can be purchased as an optional accessory.
Rear a Handle for transportation (arrows) b Power cord with plug c Slot for module d Air intake e Gas connection f Vent connection with restriction insert , WARNING Do not remove the restriction insert in the vent opening. It may result in poor drying results, damage to the laundry and higher Carbon monoxide emissions.
, WARNING: Do not install the dryer: - outdoors - in an environment with dripping water or weather - near flammable materials - in rooms which may contain gas or other fuels - in closets with solid doors - with other fuel-burning appliances in the same closet - in a location where its door could conflict with room doors.
Confined space installation ^ When installed in any space with less than 122 square feet, minimum clearances around the dryer must be adhered to for proper ventilation and vents for make up air must be installed. ^ Do not install any other fuel-burning appliance in the same space as the dryer.
Transporting the dryer to the installation site The rear of the lid has a handle for transportation. ^ Use the front dryer feet and the rear of the lid to move the dryer to the installation site. Level the dryer The dryer must be level to ensure safe and proper operation.
, WARNING Before installation, disconnect the tumble dryer from the electrical supply by shutting off the power main or tripping the circuit breaker. Be sure the dryer power cord is unplugged from the wall. Do not restore power until the installation is complete.
, GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance. This appliance is equipped with a cord having an equipment grounding conductor and a grounding plug.
, WARNING Installation and service must be performed by a qualified installer, service agency or gas supplier. In Massachusetts a licensed plumber / gas fitter is required. This appliance must be installed with its own shut off valve in the same room.
Gas supply Installation material (hoses and adapters) must be provided by the installer. Gas connection distances This appliance must be installed with its own shut off valve on the gas supply line. The valve must be within 6 ft. (1.8 m), and in the same room, of the dryer.
, To secure all connections use appropriate Teon tape o ra thread compound. Us ea 10" slip joint wrench only. ^ At the end of the dryer's gas connection hand screw on the 3 / 8 " NPT elbow. Using a wrench tighten the elbow wit ha half turn.
^ Using two wrenches tighten the flexible gas line connection. ^ Connect the flare union adapter, a , to the pressure tapping plug, b , originally installed on the gas shut off valve, c . ^ Using two wrenches tighten all connections. , DO NOT OVERTIGHTEN.
Exhaust ducting and connections A gap of 3 / 8 " (10 mm) must be provided between the machine and the floor. This gap is necessary for proper air flow and must not be blocked by a toe-kick or thick piled carpets. Sufficient venting of the installation site is essential for proper dryer operation.
How to calculate the effective duct length The overall duct length will determine the duct diameter. ^ Measure the actual duct length needed to go from the dryer’s exhaust connection to the vent outlet: 1. Establish the number of elbows or bends necessary, noting the type of bend, angle and radius involved (see Table).
Additional duct lengths (4" (100 mm) rigid pipe only) Type of bend Radius Additional duct length inches cm ft cm Flexible metal duct – 3’ 3" (1 m) straight – 45° angle – 90° angle .
Example Rigid pipe Duct length ft Duct length m A Wall duct with louvered wall vent 12’ 5" 3.8 m B 90° bend 2’ 4" 0.7 m C 20" (0.5 m) rigid pipe 1’ 7" 0.
Exhaust connection with a flexible exhaust hose or rigid pipe Using the connector supplied, an exhaust hose (4" [100 mm] diameter) can be installed.
Window connection (example) 1 Window duct 2 Connector for the rigid or flexible exhaust hose Wall connection (example) 1 Wall pipe (Installation sheet supplied with the Miele wall pipe) 2 Connector 3 .
Direct wall connection Necessary materials: – a wall pipe – flexible foam gasket Dryer top view 1 Wall pipe 2 Flexible foam gasket Dryer side view 1 Wall pipe 2 Flexible foam gasket ^ Connect the flexible foam gasket, 2 , to the wall pipe connector, 1 .
Disposal of the packing materials The packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. To prevent suffocation, ensure that any plastic wrappings, bags, etc. are disposed of safely and kept out of the reach of children.
26.
27.
All rights reserved / 0208 For the most updated manual please see the Miele web site. M.-Nr. 07 268 180 / 00.
デバイスMiele T9820の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Miele T9820をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMiele T9820の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Miele T9820の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Miele T9820で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Miele T9820を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMiele T9820の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Miele T9820に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMiele T9820デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。