Milan TechnologyメーカーMIL-S1000の使用説明書/サービス説明書
ページ先へ移動 of 42
MIL-S1000 User ’ s Manual.
Copyright S tatem ent COPYRIGH T 1999 ALL RIGHT RESERVED. First Edition. Printed in T aiwan. All trade marks are th e proper ties of thei r respecti ve ow ners. No portio n of this document may be repr oduced, alt ered, adapted or translate d without the pri or wr itten approv al.
Table of Contents Chapter 1 Introduction Package Contents……….……………… …………………….. 1-2 Device Description, Features and Capabilities …………… 1-3 MIL-S1000 Front and Rea r Panels……….……………… 1-3 8 ports 10/100Base -TX Module…….
Chapter 3 In stallation Choosing A Location………………………… ……………….. 3-1 Rack Installation……………… ………………………… …….. 3-2 Supplying Power………………………… ……………………. 3-3 Connecting the Switch.
Chapter 1 Int roducti on MIL-S100 0 switches ar e multi-speed networ k devices combining Ethernet , Fast Ethernet and Gigabit Ethernet capabilities in a single compact, ra ck-mountable cab inet.
Package Cont ents Power Cord Rubber Fee t Manual War rant y Car d Rack-Moun t Ki t Figure 1-1. Package Contents The MIL-S 1000 packag e contains th e follow ing: ! MIL-S1000 switch ! AC power cord ! R.
Device Description, Features and C apabilities MIL-S1000 Front and R ear Panels This section describes th e features on the front and rear panels o f the MIL-S1 000 unit . Figure 1-2. Fr ont Panel Figure 1-3. Rear Panel All LED sta tus indicators are loc ated on th e FRONT panel of the sw itches.
LED Indicators Ex planation Power The red p ower indica tor is illumin ated when pow er is pr ovided to the switch and the switch is turn ed in the ON p osition. Link/Activ ity Green Link/Acti vity i ndicators are illuminated w hen the switch d etects a connection to that port.
" Power Switch The pow er switch, l ocated on the r ear pa nel, controls the power supply ..
8 ports 10/100Base-TX Module Figure 1-4. 8 port 10/100Base-TX Module W hen installe d into a MI L-S10 00 switch , th e 10/1 00Ba se- TX Module provides 8 1 0/100M bps Sw itch ports w hich can connect the M IL-S10 00 to a 10Mb ps or 100Mbps sw itch or end statio n.
DIP Switch with Link Mode The 8 port 10/100Bas e-TX modul e prov ides dip sw itch for 1 to 4 p ort to adj ust link mode w ith other n etwor k devices. Another 4 ports use aut o-negotia tion protoc ol only . There are thre e type o f link mode can be chosen, Auto- negotiatio n, 100Mb ps/Full dupl ex and 1 0Mbps/Ful l duplex .
The follow ing T able 1- 1. lists t he ports’ operating modes based on th e DIP swit ch position. PORT 1 PORT 2 PORT3 PORT4 S W 12 34 56 7 8 ON Full 10M Full 10M F ull 10M Full 10M OFF Auto 100M Auto 100M Auto 100M Auto 100M T able 1-1.
2 ports 100Base-F X Fiber Module Figure 1-6. 2 port 100Base-FX Module Fr ont V iew W hen installe d into a MIL-S10 00 switch , t his Module provi des a 1 00Mbps Fast Eth ernet fiber p ort whi ch can b.
P o rt 2 P o rt 1 DI P S w i t ch Lo cat i on Ful l D upl ex Ha l f D u p l ex 2 1 ON OF F Figure 1-7. Dip switch location and mode settings The follow ing T able 1- 2. lists t he ports’ operating modes based on th e DIP swit ch position. POR T 1 POR T 2 SW 1 2 ON Half-Dupl ex Half-Dupl ex OFF Full-D uplex Full-D uplex T able 1-2.
" Store-an d-forw ard swit ch architecture for abnor mal packet filte ring " 2 switchi ng 100Mbps Fib er Etherne t ports " Backplane up to 2.4G bps " Automati c address le arning w ith 12K addr ess entry storage " Filteri ng and forw arding r ate of 148, 800 pack ets per second " 100Base-FX uses 62.
4 Ports 100Base-F X Fiber Module Figure 1-8. 4 port 100Base-TX/FX Fr ont V iew W hen installe d into a MIL-S10 00 switch , t his Module provi des 4 x 100Mb ps Fast Ether net fiber ports whi ch can be used to: # Connec t the Sw itch to the backbone of your netw ork; that is, to a baseme nt switch, hu b or ro uter .
P o rt 1 P o rt 3 P o rt 4 P o rt 2 DI P S w i t ch Lo ca t i on Ful l Du p l ex Ha l f D u p l ex 4 3 2 1 ON OF F Figure 1-9. Location and setting duplex mode The follow ing T able1-3. lists th e ports o perating mod es based on th e DIP swit ch position.
" Backplane up to 2.4G bps " Automati c address le arning w ith 12K addr ess entry storage " Filteri ng and forw arding r ate 148,80 0 packets per sec ond for 100M bps " 100Base-FX uses 62.
1000Base-SX/LX F iber Module Figure 1-10. 1000Base-SX/LX Fr ont V iew W hen installe d into a MIL -S1000 s witch, t he 1000 Base - SX/LX M odule prov ides 1 Gig abit Ethernet por ts which can connect the M IL-S10 00 to a Gig abit Backbo ne Sw itch or Server w ith Gigabit NIC.
DI P S w i t ch Loca t i on Ful l Du p l ex Ena bl e N- w a y Di sab l e N- w a y Ha l f D upl ex DI P 2 DI P 1 2 1 ON OF F Figure 1-1 1. Location and setting duplex mode If you adj ust to En able N-W ay , then the DI P for Hal f-Duplex and Full -Duplex is not ef fectiv e.
Chapter 2 Pl anning y our Ne twork Before y ou install y our MIL- S1000, you shoul d review the guideli nes for setting up Ether net networ ks. Further , you should pl an your networ k to take max imu m advantage o f its switching capabilities.
100Base-TX Ethernet Network Guide lines # The max imum l ength of a 100Base- TX cable seg ment is 100 me ters (32 8 feet). # The maximu m number of hubs o n a 100Base- TX segment is one if usi ng Class I hubs and tw o if using Class II hubs. # Th e recommen ded cable ty pe is E IA/TIA Cat egory 5 unshielded tw isted- pair .
1000BASE-SX and L X Network Guideline 1000BASE- SX # In multi-mo de, th e fiber opti c segme nt cannot exceed 220m(62 .5/125 µ m) or 50 0m(50/1 25 µ m) in leng th. 1000BASE- LX # In multi-mo de, th e fiber opti c segme nt cannot exceed 550m(62 .5/125 µ m), 550m( 50/125 µ m) in length.
T o expand your netw ork topolog y or enhance netw ork performanc e, use t he MIL-S10 00 as collapsed back bone or to increas e file ser ver perfor mance, to segment large networks, to i ntercon nect 10Mbps n etworks w ith 100Mbps networks, or to ov ercome the limi tations of 10Base- T and 100Base- TX networks.
100Base-TX N etworks The hub li mit of a 1 00Base-TX networ k depends on the class of the hub in the n etwork. W it h a Class I h ub, the network is limited t o one hub. W ith a Class II hub, the network is limited t o two hu bs. Howev er , you can ex pand your 1 00Base-TX netw ork that includes either class of hub by adding a MIL-S100 0.
Collapsed Backbone Link T raditi onally , bridg es and rou ters hav e been used to link local ar ea ne tworks into one int erconnect ed netw ork. But these dev ices inv olv e dif ficult ma nagement a nd long traf fic delays.
Figure 2-3. MIL-S1000 100/1000 Hub in a collapsed backbone link Fileserver Link 100Base Solution W it h a fileserver link, you can increas e file ser ver performanc e by i ncreasing th e Hub's ba ndwidth b etween one or m ore files ervers and th e work groups they serve.
Figure 2-4. Fileserver Link Connecti ng serv ers through 10 0Base-TX p orts increases performanc e to the clients, ev en i f the clients ar e on 10Base-T seg ments.
1000Base Solution Y ou can upg rade y our serv er with a Gi gabit Ether net NIC, and i ntroduce a Gig abit backbone swit ch too. This contains several sw itch ports w hich prov ides much faster access to y our server with minim um disrup tion. See Figur e 16.
Figure 2-5. Used as a Multiport Bridge Using your hub, y ou can also c onnect 10B ase-T networ ks and 100Bas e-TX an d 1000Bas e-SX/LX networks together for more flexibility in your netw ork topology .
Chapter 3 Instal latio n The MIL-S1000 can be installed quickly and easily . However , for an installation with minimum impact on the exist ing network, please r ead thi s chapter caref ully . Installing a MIL-S1000 in volves three step s: 1. Choosing a loc ation 2.
switch on a d esktop or in a rack. Figure 3-1. Attaching self-adhesive feet for desktop installation Rack Inst allation Y our switch comes w ith two rack mounting brackets. you can use t hese brackets to mount th e switch on an EIA standard 19" r ack.
The MIL-S 1000 sw itch is eq uipped w ith a univer sal switchi ng power supply that accepts AC i nput vol tages from 100 to 240V AC and 5 0 to 60 H z. T o supply pow er to your switch: 1. Plug the c onnector of the pow er cord int o the pow er port on the re ar panel o f your switch.
Connecting the Swit ch Y ou can con nect your sw itch to network dev ices such as desktops and w orkgr oups or to ot her hubs. Before con necting y our switch to a desktop or wor kgroup make sure that: # The 10Bas e-T tw isted pair Et hernet cabling is Category 3 or abov e.
Chapter 4. M odule Install ation and Removal W ARNING Before installing the Modules into a MIL-S1000, you must disconnect the Switch from the main power supply .
Module Setup and Installation 1. Ensure that th e Switch i s disconnect ed from th e main power supply and tha t you are w earing an anti- static wrist- band connected to a suit able g rounding p oint. 2. Place t he Sw itch on a fl at sur face. Using a s mall cross- bladed scr ewdriv er , remove the blanking plate from the rear of t he Swi tch.
Installing the Module s Installing 10/100B ase-TX Modules a. Insert t he RJ- 45 con nector o n your cabl e into the socket of t he Modu le. b. C onnect the o ther end of the cable to an appropriat e devic e wi th a 100Mbps Fast Ethernet or 10Mbps Ethernet tw isted pai r inter face.
Installing 1000Base-SX/LX Modules a. Remove the pro tective plasti c cov ers from the fiber connectors o n the Mo dule. b. Ensur e that th e Switch i s power ed up.
Appendi x A. T echnical S pecif ications Compatibility with Et hernet Stan dards: The MIL-S 1000 has b een designe d in accor dance with IEEE Standar d 802.
3 Mbyt es memory share per 100 0Base-SX /LX module, maxi 12 M bytes Address T abl e 12K entry MAC Address table / per module Switching Architecture Store and Forw ard Forwarding Rate 14,880 pps/10B as.
Appendi x B. Pi n Assig nments RJ-45 statio n ports can be attach ed to any device whi ch use a standard netw ork interface ( e.g., a w orkstation, server , bridge or r outer). RJ -45 daisy -chain ports can be cascaded to a station port on simil ar network ing devices (e.
Schematics for both s traight an d crossover tw isted-pai r cable ar e shown bel ow . Straight-Through Cross-Over / Swap Switch Adapter Switch Hub 1 RD + 1 TD + 1 RD + 1 RD + 2 RD - 2 TD - 2 RD - 2 RD.
デバイスMilan Technology MIL-S1000の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Milan Technology MIL-S1000をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMilan Technology MIL-S1000の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Milan Technology MIL-S1000の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Milan Technology MIL-S1000で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Milan Technology MIL-S1000を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMilan Technology MIL-S1000の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Milan Technology MIL-S1000に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMilan Technology MIL-S1000デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。