Miller ElectricメーカーNT 456 CVの使用説明書/サービス説明書
ページ先へ移動 of 40
NT 456 CC/CV Processes Description Multiprocess W elding Arc Welding Power Source OM-2243 212 1 13T 2007 − 10 File: Multiprocess V isit our website at www.
Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual specification sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .
T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Notes.
OM-2243 Page 1 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _2007 − 04 7 Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage DANGER! − Indicates a hazardous situation which, if not avoided, will result in death or serious injury .
OM-2243 Page 2 W elding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health. FUMES AND GASES can be hazardous. Keep your head out of the fumes. Do not breathe the fumes. If inside, ventilate the area and/or use local forced ventilation at the arc to remove welding fumes and gases.
OM-2243 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. Do not install or place unit on, over , or near combustible surfaces.
OM-2243 Page 4 1-4. California Proposition 65 W arnings W elding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer . (California Health & Safety Code Section 25249.
OM-2243 Page 5 SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE A V ANT UTILISA TION fre_som_2007 − 04 7 Se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes.
OM-2243 Page 6 Il reste une TENSION DC NON NÉGLIGEABLE dans les sources de soudage onduleur quand on a coupé l’alimentation. Arrêter les convertisseurs, débrancher le courant électrique et décharger les condensateurs d’alimentation selon les instructions indiquées dans la partie Entretien avant de toucher les pièces.
OM-2243 Page 7 LES ACCUMULA TIONS DE GAZ risquent de provoquer des blessures ou même la mort. Fermer l’alimentation du gaz protecteur en cas de non-utilisation. V eiller toujours à bien aérer les espaces confi- nés ou se servir d’un respirateur d’adduction d’air homologué.
OM-2243 Page 8 LES FILS DE SOUDAGE peuvent provoquer des blessures. Ne pas appuyer sur la gâchette avant d’en avoir reçu l’instruction. Ne pas diriger le pistolet vers soi, d’autres per- sonnes ou toute pièce mécanique en enga- geant le fil de soudage.
OM-2243 Page 9 2-5. P r i nc ip al e s n or m e s d e sé c ur i té Safety i n W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, de Global Engineering Documents (téléphone : 1-877-413-5184, site Internet : www .
OM-2243 Page 10.
OM-2243 Page 1 1 SECTION 3 − DEFINITIONS 3-1. Nameplate Safety Symbols 1 W arning! W atch Out! There are possible hazards as shown by the symbols. 2 Electric shock from welding electrode or wiring can kill. 3 Sparks from arcing electrode can cause explosion or fire − disconnect cable for process not in use.
OM-2243 Page 12 SECTION 4 − INST ALLA TION 4-1. Specifications Model Rated W elding Output Amperage/V oltage Range Max OCV − DC Amperes Input at Rated Load Output 60 Hz, Three-Phase Model O utput Range Max OCV − DC 230 V 460 V 575 V KV A KW 450 Amp 450 A @ 38 V olts DC 100% Duty 5 − 500A In CC Mode 78 VDC In CC Mode 58 29 23 22.
OM-2243 Page 13 4-3. V olt-Ampere Curves V olt-ampere curves show mini- mum and maximum voltage and amperage output capabilities of unit. Curves of other settings fall be- tween curves shown. va_curve1 − 4/95 − 212 1 11-A / 212 1 12-A A. CC Mode B.
OM-2243 Page 14 4-4. Selecting A Location 1 Lifting Eye 2 Lifting Forks Use lifting eye or lifting forks to move unit. If using lifting forks, extend forks beyond opposite side of unit. 3 Rating Label Use rating label to determine input power needs. 4 Line Disconnect Device Locate unit near correct input pow- er supply .
OM-2243 Page 15 4-5. Dimensions And Weights Dimensions A 32-1/2 in (826 mm) including lift eye B 23 in (585 mm) C 38 in (966 mm) including strain relief D 35 in (889 mm) E 1-1/4 in (32 mm) F 21-1/8 in.
OM-2243 Page 16 4-6. Tipping ! Be careful when placing or moving unit over uneven surfaces. 4-7. 1 15 V AC Receptacle And Circuit Breakers Ref. 800 166-D ! T urn Off power before connecting to receptacle. 1 1 15 V 15 A AC Receptacle RC15 Power is shared between RC15 and Remote 14 receptacle RC14 (see Section 4-1 1).
OM-2243 Page 17 4-8. W eld Output T erminals And Selecting Cable Sizes ! T u rn Off power before T otal Cable (Copper) Length In Weld Circuit Not Exceeding ! T urn Off power b e f ore connecting to weld output terminals.
OM-2243 Page 18 4-10. Remote 14 Receptacle Information Socket* Socket Information 24 VOL TS AC A 24 volts ac. Protected by circuit breaker CB2. B Contact closure to A completes 24 volts ac contactor control circuit. 1 15 VOL TS AC I 1 15 volts ac. Protected by circuit breaker CB1.
OM-2243 Page 19 4-12. Electrical Service Guide Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommenda- tions are for a dedicated branch circuit sized for the rated output and duty cycle of the welding power source.
OM-2243 Page 20 4-14. Connecting Input Power 800 103-C / Ref. 801 1 16-A 3/8 in 3/8 in T ools Needed: ! Installation must meet all National an d Local Codes − have only quali- fied persons make this installation. ! Disconnect and lockout/tagout in- put power before connecting input conductors from unit.
OM-2243 Page 21 SECTION 5 − OPERA TION 5-1. Controls 229 450-A 1 6 7 4 8 2 3 5 1 Power Switch This unit is equipped with a fan motor that is thermostatically controlled and only runs when cooling is needed (fan-on-de- mand). If unit is not equipped with fan-on- demand, fan motor runs when power is on.
OM-2243 Page 22 5-2. Meter Functions For CC/CV Models The meters display the actual weld output values for approximately three seconds after the arc is broken. Mode Meter Reading At Idle Scratch Start TIG Actual V olts (OCV) Preset Amps VA 78.0 85 Lift-Arc TIG (GT AW) VA Actual V olts Preset Amps 8.
OM-2243 Page 23 5-3. Lift-Arc TIG Procedure For CC/CV Models With Mode switch in the Lift-Arc TIG position, start an arc as follows: 1 TIG Electrode 2 W orkpiece T ouch tungsten electrode to work- piece at weld start point, hold electrode to workpiece for 1-2 seconds , and slowly lift electrode.
OM-2243 Page 24 SECTION 6 − MAINTENANCE & TROUBLESHOOTING 6-1. Routine Maintenance Maintain more often during severe conditions. ! Disconnect power before maintaining.
OM-2243 Page 25 6-3. V oltmeter/Ammeter Help Displays Al l directions are in reference to the front of the unit. All circuitry referred to is located inside the unit. 1 Help 0 Display Indicates a shorted thermistor in the transformer of the unit. If this display is shown, contact a Factory Autho- rized Service Agent.
OM-2243 Page 26 6-4. T roubleshooting T rouble Remedy No weld output; unit completely inop- erative; pilot light PL1 off. Place line disconnect device in On position (see Section 4-14 ). Check for open line fuse(s), and replace if open (see Section 4-14 ).
OM-2243 Page 27 SECTION 7 − ELECTRICAL DIAGRAM 223 809-D Figure 7-1. Circuit Diagram For NT 456 CC/CV Models.
OM-2243 Page 28 SECTION 8 − P ARTS LIST 803 621-C Hardware is common and not available unless listed. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 3 2 15 17 18 19 20 21 21 23 24 25 26 27 28 29 31 30 16 22 Figure 8-1. Main Assembly Description Part No. Dia. Mkgs.
OM-2243 Page 29 Description Part No. Dia. Mkgs. Item No. Figure 8-1. Main Assembly (Continued) Quantity 14 TE1 159 244 PRIMARY BOX (Includes), 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 601 835 NUT , 10-32 BRASS 24 .
OM-2243 Page 30 803 623-G Hardware is common and not available unless listed. Hardware is common and not available unless listed. 1 2 3 4 5 3 4 7 6 8 9 10 22 23 22 24 11 13 12 15 16 18 19 20 21 17 14 25 26 27 28 29 12 30 Figure 8-2.
OM-2243 Page 31 Figure 8-2. Panel, Front With Components (Fig 8-1 Item 1) Description Quantity Part No. Dia. Mkgs. Item No. 1 204 143 P ANEL, FRONT 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-2243 Page 32 Hardware is common and not available unless listed. 803 937-C 1 2 2 3 4 5 6 9 10 11 12 7 13 8 14 Figure 8-3. IGBT/Capacitor Assembly.
OM-2243 Page 33 Description Part No. Dia. Mkgs. 221 298 Item No. Quantity Figure 8-3. IGBT/Capacitor Assembly (Fig 8-1 item 23) 1 221 301 BUS PLA TE, IGBT TO CAP ACITOR NEGA TIVE 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-2243 Page 34 Hardware is common and not available unless listed. 1 ST-800 707-C 2 3 4 5 6 9 7 8 10 Figure 8-4. Panel, Rear With Components Figure 8-4. Panel, Rear With Components (Fig 8-1 Item 9) Description Quantity Part No. Dia. Mkgs. Item No.
Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 2007 − 01 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours.
PRINTED IN USA © 2007 Miller Electric Mfg. Co. 2007 − 01 Miller Elect ric Mfg. Co. An Illinois T ool Wo rks Compan y 1635 West S pencer S treet Applet on, WI 5 4914 US A International He adquarter .
デバイスMiller Electric NT 456 CVの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Miller Electric NT 456 CVをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMiller Electric NT 456 CVの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Miller Electric NT 456 CVの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Miller Electric NT 456 CVで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Miller Electric NT 456 CVを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMiller Electric NT 456 CVの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Miller Electric NT 456 CVに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMiller Electric NT 456 CVデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。