PELLERIN MILNOR CORPORATION BICWUT01 (Published) Book specs- Dates: 20050118 / 20050118 / 20050118 Lang: ENG01 Applic: CWU Troubleshooting Basket Speed Errors on Single-motor Washer- extractors This d.
Troubleshooting Basket Speed Errors o n Single-motor Washer-extra ctors PELLERIN MILNOR CORPORATION Figure 1: Troubleshooting Spe ed Errors Process Chart Legend . Y. Yes N. No 1. Machine does not run at desire d speed. 2. Section 1: Is desired speed prog rammed in wash formula? A.
PELLERIN MILNOR CORPORATION 1. Verify Programmed Speed Verify that the machine is programmed correctly . The desired basket speed is programmed on the second page of each wash formula step. Display or Action Explanation P Insert the programming key into the Run/Program keyswitch and turn the key 1/4 turn to the right.
Troubleshooting Basket Speed Errors o n Single-motor Washer-extra ctors PELLERIN MILNOR CORPORATION Display or Action Explanation F01 T MMQFFFHC3WLL S S01 2 050150133110 0 The first page of step decisions includes the type and duration of the step, the desired temperature, water valves, fill action, bath level, and steam code.
PELLERIN MILNOR CORPORATION to increase the basket speed by two RPMs or decrease the speed by one RPM at each adjustment. These adjustments are made three seconds before the end of the programmed basket On time (programming decision XXX ).
Troubleshooting Basket Speed Errors o n Single-motor Washer-extra ctors PELLERIN MILNOR CORPORATION Table 1: Model-Specific Data Machine Model Maximum Frequency Maximum Wash RPM Counts per RPM (C/RPM).
PELLERIN MILNOR CORPORATION b. Calculate the desired counts for a basket speed of 24 RPMs: C d = [RPM d * (C/RPM)] + D C d = [24 RPMs * (6 counts per RPM)] + 15 159 = 144 + 15 c. Calculate the desired voltage: V d = C d / 409.5 0.3883 = 159 / 409.5 2.
Troubleshooting Basket Speed Errors o n Single-motor Washer-extra ctors PELLERIN MILNOR CORPORATION 4. If the value is correct at the D-to-A board but wrong at the inverter, check the wiring between the board and the inverter. 5. If the value is correct at both sets of terminals, troubleshoot the inverter.
PELLERIN MILNOR CORPORATION 6. Testing the Motor If the procedures described earlier in this documen t do not eliminate the error, have the motor tested by a reputable facility.
デバイスMilnor BICWUT01の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Milnor BICWUT01をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMilnor BICWUT01の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Milnor BICWUT01の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Milnor BICWUT01で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Milnor BICWUT01を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMilnor BICWUT01の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Milnor BICWUT01に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMilnor BICWUT01デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。