Milwaukeeメーカー2282-20の使用説明書/サービス説明書
ページ先へ移動 of 19
Milwaukee 2282 - 20 1 EN Table of Contents Genaral Safety Instructions - - - - - - - - - - - - - 2 Instrument Set-up - - - - - - - - - - - - - - - - - - - - - - - 3 Introduction - - - - - - - - - - - .
Milwaukee 2282 - 20 2 EN Genaral Safety Instructions WARNING Read all safety warnings and instructions. Before using the appliance, read these safety instructions, the appliance’s oper- ator’s manual (found on the enclosed CD) and all labels on the appliance.
Milwaukee 2282 - 20 3 EN Instrument Set-up Introduction The safety instructions and the user manual should be read through carefully before the product is used for the first time. The person responsible for the product must ensure that all users understand these directions and adhere to them.
Milwaukee 2282 - 20 Instrument Set-up 4 EN Display Horizontal measure- ment Units Stake out Slope distance Circumfer- ence Measuring reference 2nd result Area / Volume Angle Wall area Addition / Subtr.
Milwaukee 2282 - 20 Instrument Set-up 5 EN Labeling Laser Radiat ion Do not star e into the beam Laser class 2 acc. IEC 6 0825-1:2007 Maximum radia nt power: <1mW Emitted wavel eng th : 620- 690nm Beam diver gence: 0. 16 x 0.6 mrad Impulse durat ion: 0.
Milwaukee 2282 - 20 6 EN Operations Switching ON/OFF Clear Message Codes 2 sec Device is turned OFF. i Press ON but- ton 2 sec to start continuous laser mode. If no key is pressed for 180 sec, the device switches off au- tomatically. 1x Undo last a cti on.
Milwaukee 2282 - 20 Operations 7 EN Adjusting measuring reference / tripod Distance is measured from the front of the device. 1 Distance is measured from the tripod thread permanently. 2 Distance is measured from the rear of the device (standard setting).
Milwaukee 2282 - 20 Operations 8 EN Distance unit setting Tilt unit setting 0.000 m 0.0000 m 0.00 m 0.00 ft 0‘00‘‘ 1/32 0.00 in 0 in 1/32 Switch between the following units: 2 sec 0.0 ° 0.0 % 2 sec simult aneously Switch between the following units: Timer (automatic release) s 1 Adjust delay of au- tomatic release (max.
Milwaukee 2282 - 20 9 EN Measuring Functions Measuring single distance 1 Aim active laser at target. 2 8.532 m 3 i Target surfaces: Measuring errors can occur when meas- uring to colourless l iquids, glass, styrofoam or semi-per- meable surfaces or when aiming at high gloss surfac- es.
Milwaukee 2282 - 20 Measuring Functions 10 EN Area 1 1x 2 Aim laser at first target point. 3 4 Aim laser at sec- ond target point. 24.352 m 2 5 i The result is shown in the main line and the measured value above.
Milwaukee 2282 - 20 Measuring Functions 11 EN Volume 1 2x 2 Aim laser at first target point. 3 4 Aim laser at sec- ond target point. 5 6 Aim laser at third target point. 78.694 m 3 7 i The result i s shown in the main line and the measured value above.
Milwaukee 2282 - 20 Measuring Functions 12 EN Pythagoras (2-point) 1 2 Aim laser at up- per point . 3 4 Aim laser rectan- gular at lower point. 8.294 m 5 i Notice additional Pythagoras measurement in- formation at the bottom of the next page. Pythagoras (3-point) 1 2x 2 Aim laser at up- per point .
Milwaukee 2282 - 20 Measuring Functions 13 EN Pythagoras (partial height) 1 3x 2 Aim laser at upper point. 3 4 Aim laser at 2nd point. 5 6 Aim laser at rec- tangular point. 2.602 m 7 i • Pressing the measuring key for 2 sec in the functi on activates automatically Minimum or Maximum measurement.
Milwaukee 2282 - 20 Measuring Functions 14 EN Stake out i Two different distances (a and b) can be entered to mark off de- fined meas- ured len gths. 1 2 3 a = b a b b 1 2 3 a b b a = b 1 .000 m 1 4x 1. 01 2 m Adjust value "a". 2 3 Approve value "a".
Milwaukee 2282 - 20 Measuring Functions 15 EN Smart Horizontal Mode 1 Aim laser at target. 2 z x y 0.032 m 5.20 4 m 40.8 ° 4.827 m x y z 3 (up to 360° and a tra nsverse tilt of ±10°) i Press key again to switch off horizontal measure- ment.
Milwaukee 2282 - 20 Measuring Functions 16 EN Memory (20 last displays) Delete Memory 8.294 m 20 20 last displays are displayed. 1 8.294 m 20 Navigates trough 20 last displays. 2 The value from the main line can be used for fur- ther calculations. 2 sec 3 2 sec simultaneously Memory is completely de- leted.
Milwaukee 2282 - 20 17 EN Calibration Calibration of tilt sensor (Tilt Calibration) 1 2 sec simultane- ously 2 Place device on absolutely flat sur- face. 3 180° 4 Turn the device horizontal ly by 180° and place it again on absolutel y flat surface. 5 6 Turn the device and place it again on ab- solutely flat surface.
Milwaukee 2282 - 20 18 EN Technical Data * applies f or 100 % target reflectivity (white pain ted wall), low backg ro un d illu min at ion, 25 ºC ** applies fo r 10 to 500 % target ref lectivit y, high back- ground illumin ation, - 10 ºC to + 50 ºC *** Tolera nces apply fr om 0.
Milwaukee 2282 - 20 Care 19 EN Care • Clean the device with a damp, soft cloth. • Never immerse the device in water. • Never use aggressive cleaning agents or solvents. Service - United States MILWAUKEE prides itself in producing a premium quality product that is Nothing But Heavy Duty ® .
デバイスMilwaukee 2282-20の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Milwaukee 2282-20をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMilwaukee 2282-20の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Milwaukee 2282-20の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Milwaukee 2282-20で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Milwaukee 2282-20を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMilwaukee 2282-20の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Milwaukee 2282-20に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMilwaukee 2282-20デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。