TECHNICAL & SER VICE MANUAL DUCTLESS SPLIT -TYPE AIR CONDITIONERS CONTENTS 1. FEA TURES ·························································2 2. TECHNICAL CHANGES ····································3 3.
2 1 FEA TURES This “2 to 1” Multi system consists of a single outdoor unit with two compressors that permit up to two indoor units to be installed separate rooms, each with its own controller . 1.SP ACE-SA VING LA YOUT T wo indoor units are served by a single outdoor unit whose installation requires only minimum space.
3 2 TECHNICAL CHANGES 3 P ART NAMES AND FUNCTIONS OUTDOOR UNIT MUM18NW MSM18EW ➔ MSM18NW 1. Indoor unit has been changed. 2. Outdoor unit has been changed. 3. Remove controller has been changed. (The timer function was changed to the clock timer function.
4 4 SPECIFICA TIONS Model MSM18NW SINGLE DOUBLE Cooling capacity w 1 BTU/h 8,400 8,400 ✕ 2 850 1,700 9.9 10.0 MS09NW ✕ 2 White 1 15,60,1 15 0.5 0.37 208-265-328 177-226-279 – 5/8 32-1/16 7-3/16 10-13/16 18 Max.
Models Indoor air Outdoor intake air DB temperature ( ˚F ) MS09NW 71 67 63 TC 10.3 9.74 9.16 SHC 5.93 6.91 7.72 TPC 0.76 0.71 0.68 TC 9.61 9.07 8.48 SHC 5.55 6.44 7.16 TPC 0.83 0.79 0.75 TC 9.03 8.4 7.9 SHC 5.21 5.95 6.66 TPC 0.89 0.85 0.81 TC 8.4 7.
6 3.CONDENSING PRESSURE AND SUCTION PRESURE (ONE INDOOR UNIT WITH ONE OUTDOOR UNIT) Data is based on the condition of indoor humidity 50%. Air flow should be set at HI.
7 Model Unit Single Double MSM18NW 8,400 8,400 ✕ 2 0.71 0.71 0.85 1.70 0.815 1.63 6.64 7.16 ✕ 2 260 270 75 75 194 191 1 16 1 18 64 54 60 60 57 57 Cooling MS09NW 1 15 . 60 . 1 0.035 ✕ 2 0.34 ✕ 2 MUM18NW 208/230 . 60 . 1(3-wire) 1.0 172 25 ✕ 2 1lds 14oz ✕ 2 80 67 1,230 279 95 — 900 1,150 Btu/h — kW kW A kW A A psi .
8 4.OPERA TING RANGE ( 1 ) POWER SUPPL Y ( 2 ) OPERA TION 5.ADDITIONAL REFRIGERANT CHARGE (R-22(oz)) Indoor unit 1 15V 60Hz 1 [ 208/230V 60Hz 1 [ (3wires) Min.
9 6 OUTLINES AND DIMENSIONS MODEL : MUM18NW OUTDOOR UNIT REAR VIEW Unit center Refrigerant pipe(Flared) { 3/8 Refrigerant pipe(Flared) { 1/4 7/8 Wiring hole { 3-7/8 NOTE : The symbol { indicates diameter .
10 7 WIRING DIAGRAM OUTDOOR MODEL MUM18NW WIRING DIAGRAM F NR 1 15V 3 4 BLK BRN 2 1 BLU GRY N ❈ ❈ ❈ BLK ORN YL W X2 X1 2 2 6 6 4 4 YL W BLU L2 BLU RED TB3 TO INDOOR UNIT No.
11 8 REFRIGERANT SYSTEM DIAGRAM MS09NW ✕ 2/ MUM18NW Unit : inch Indoor unit Outdoor unit Indoor heat exchanger Indoor coil thermistor RT12 Room temperature thermistor RT1 1 Flared connection Flared .
12 9 TROUBLESHOOTING MUM18NW 9-1 Cautions on troubleshooting 9-1-1 Before troubleshooting, check the followings: 1) Check the power supply voltage. 2) Check the indoor/outdoor connecting wire for mis-wiring. 9-1-2 T ake care the followings during servicing.
13 Compressor and outdoor fan do not operate.(Only indoor fan operates.) Check of outdoor unit Press EMERGENCY ON/OFF button. 3-minute time delay works. T est mode operates for 30 minutes. Check the outdoor fan motor , compressor , relay , contactor , and wiring.
14 10 DISASSEMBL Y INSTRUCTIONS OUTDOOR UNIT MUM18NW 1. Removing of the cabinet (1)Remove the set screws of the valve cover to remove the valve cover as shown in Photo 2. (2)Remove the set screws of the side panel to remove the side panel and cabinet.
15 OPERA TING PROCEDURE PHOTOS Photo 5 Photo 6 3. Removing the outdoor fan motor . (1) Remove the cabinet. (Refer to 1) (2) Remove the propeller . (Refer to 2) (3) Disconnect the connector remove the clamp of out- door fan motor lead wire. (4) Remove the screws fixing the outdoor fan motor .
16 OPERA TING PROCEDURE PHOTOS Photo 7 Photo 8 4. Removing the compressor (1)Disconnect the cord connector . (See Phot 5) (2)Remove the set screws of the relay panel. (3)Remove the set nuts of the terminal cover . (4)Pull up the compressor . (5)Pull out the lead wires from the compressor terminal to remove overcurrent relay .
17 1 1 P ARTS LIST OUTDOOR UNIT P ARTS MUM18NW Refer to MS09EW for indoor unit. No. Parts No. Remarks Parts Name Symbol in Wiring Diagram Q , ty/unit MUM18NW 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 16 17.
18 12 OPTIONAL P ARTS 10ft 16ft 23ft 33ft 3/8 1/4 C 13/16 D 1-1/16 MAC - 440PI MAC - 441PI MAC - 442PI MAC - 443PI MS09NW 0 1 Pipe length Cross-section Part No. Model A-Gas B-Liquid Pipe size O.D Insulation Additional refrigerant charge R-22(Oz) 1. REFRIGERANT PIPES The air conditioner has flared connections its indoor and outdoor sides.
OB202-1.qxp 26/9/97 11:08 AM Page 19.
New publication, effective Sep. 1997. Specifications subject to change without notice. The Slim Line. From Mitsubishi Electric. L I S T E D R C Copyright 1997 MITSUBISHI ELECTRIC ENGINEERING CO.
3400 Lawrenceville Suwanee Road ● Suwanee, Georgia 30024 Toll Free: 800-433-4822 ● Toll Free Fax: 800-889-9904 www.mrslim.com Specifications are subject to ch ange without notice.
デバイスMitsubishi Electronics MUM18NWの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Mitsubishi Electronics MUM18NWをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMitsubishi Electronics MUM18NWの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Mitsubishi Electronics MUM18NWの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Mitsubishi Electronics MUM18NWで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Mitsubishi Electronics MUM18NWを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMitsubishi Electronics MUM18NWの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Mitsubishi Electronics MUM18NWに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMitsubishi Electronics MUM18NWデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。