Mitsumi electronicメーカーMSZ-GA71 VAの使用説明書/サービス説明書
ページ先へ移動 of 8
1 SG79Y513H02 SPLIT -TYPE AIR CONDITIONERS Models MSZ-GA50 V A MSZ-GA60 V A MSZ-GA71 V A MSZ-GA80 V A [FLARE CONNECTION TYPE] INST ALLA TION MANUAL CAUTION ■ Earth the unit. Do not connect the earth to a gas pipe, water pipe, lightning rod or telephone earth.
1 2 H D C 7 B G 3 6 8 8 E F K 4 A 7 mm or more 500 mm or more 100 mm or more 100 mm or more 500 mm or more 350 mm or more Note: Do not obstruct the air outlet. 72 mm or more 100 mm or more for left and left back piping (using spacer) 120 mm or more 200 mm or more 5 Air outlet 4-10 mm × 21 mm slot Be careful the drain hose is not raised.
4. INDOOR UNIT INST ALLA TION 4-1 FIXING OF INST ALLA TION PLA TE • Find a structural material (such as a stud) in the wall and fix installation plate horizontally . When bolts recessed in the concrete wall are to be utilized, secure the installation plate using 1 1 × 20 · 1 1 × 26 oval hole (450 mm pitch).
Drain hose Liquid pipe Gas pipe Felt tape Indoor/outdoor unit connecting wire CAUTION • Be careful not to make mis-wiring. • Firmly tighten the terminal screws to prevent them from loosening. • After tightening, p ull the wires lightly to confirm that they do not move.
10 m or less 15 m or less 25 m or less Power supply cord Specification Indoor and Outdoor connecting wire Specification 5. OUTDOOR UNIT INST ALLA TION INDOOR/OUTDOOR UNIT CONNECTING WIRE CON- NECTION AND OUTDOOR POWER SUPPL Y CORD CONNECTION • Connect the indoor/outdoor unit connecting wire from the indoor unit correctly on the terminal block.
6-3 PIPE CONNECTION Note: Fasten a flare nut with a torque wrench as specified in the table below . When fastened too tight, a flare nut may broken after a long period and cause a leakage of refrigerant. 1 Indoor unit connection Connect both liquid and gas pipings to indoor unit.
PURGING PROCEDURES Connect the refrigerant pipes (both liquid pipe and the gas pipe) between the indoor and the outdoor unit. Remove the service port cap of the stop valve on the side of the outdoor unit gas pipe. (The stop valve will not work in it initial state fresh out of the factory (totally closed with cap on).
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODAKU, TOKYO 100-8310, JAP AN 7-4 GAS CHARGE 1 Connect gas cylinder to the service port of stop valve (3-way). 2 Execute air purge of the pipe (or hose) coming from refrigerant gas cylinder . 3 Replenish specified amount of the refrigerant, while operating the air conditioner for cooling.
デバイスMitsumi electronic MSZ-GA71 VAの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Mitsumi electronic MSZ-GA71 VAをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMitsumi electronic MSZ-GA71 VAの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Mitsumi electronic MSZ-GA71 VAの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Mitsumi electronic MSZ-GA71 VAで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Mitsumi electronic MSZ-GA71 VAを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMitsumi electronic MSZ-GA71 VAの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Mitsumi electronic MSZ-GA71 VAに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMitsumi electronic MSZ-GA71 VAデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。