Installation Instructions T ype C Boilers G.C.N: 41-116-05 LEA VE THESE INSTRUCTIONS WITH THE END-USER Countr y of destination: GB.
This manual is an integr al and essential par t of the product. It should be kept with the appliance so that it can be consulted by the user and our authorised personnel.
3 1.1 G ENERAL I NSTRUCTIONS Read the instructions and recommendations in these Installation Instructions carefully to ensure proper installation, use and maintenance of the appliance.
4 The technical inf ormation and instr uctions provided herein below are intended f or the installer so that the unit ma y be installed correctly and saf ely .
F or saf ety pur poses, ha ve a competent person carefully check the electrical system in the proper ty , as the manufacturer will not be held liab le for damage caused b y the f ailure to ear th the appliance properly or b y anomalies in the supply of power .
6 The boiler operates with alternating current, as indicated in the technical inf ormation table in section 7, where the maximum absorbed power is also indicated. Make sure that the connections f or the neutral and liv e wires correspond to the indications in the diagram.
7 C ENTRAL H EA TING Detailed recommendations are given in BS 6798:1987 and BS 5449-1:1990, the f ollowing notes are giv en for general guidance . P IPE W ORK : Copper tubing to BS EN 1057:1996 is recommended f or water pipes . Jointing should be either with capillar y soldered or compression fittings.
8 Ø 60/100 mm F IG . 2.6 A BC D E F G J K HI L G F The boiler is designed to be connected to a coaxial flue discharge system. 2.9 F LUE C ONNECTIONS F LUE S YSTEM The provision f or satisfactory flue ter mination must be made in accordance with BS 5440-1.
Ø 80 mm In addition, it is also possible to use a split (twin pipe) system b y fitting a special adaptor to the flue connector and using the aper ture for the air v ent intake located on the top par t of the combustion chamber . T o utilise the air intake it is necessary to: 1.
L = Sum of the total length of exhaust + air intak e piping. 10 Exhaust T ype C12 (xx) C32 (xx) C42 (xx) Restrictor ø 41 mm L min = 0.5 m L max = 1 m Maximum Extension Exhaust/Air L = 5 m Risk of Con.
2.11 E LECTRICAL D IA GRAM 11 F IG . 2.12 Legend: A - On/Off Switch B - On/Off L.E.D . C - Heating Switch D - Heating L.E.D . E - Reset Button F - Ignition F ailure (Lock out) L.
12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 L EGEND : 1. F an 2. Main heat exchanger 3. Overheat thermostat 4. Bur ner 5. Ignition electrodes 6. Detection electrode 7. Regulation ther mostat 8. F rost ther mostat 9. Gas valv e 10. Pump pressure s witch 11.
13 3. D .H.W . ST ORA GE CYLINDER The microSYSTEM can be connected to a storage cylinder (both open-v ented and unv ented) for the production of domestic hot w ater (D .H.W .). Cylinders of diff erent capacities can be used depending on site requirements (see T ABLE 3.
14 T echnical Data Capacity Coil C.H.W . D .H.W . Max Heating Heat Ioss Surface Flow/rate Flo w/rate Output MODEL It. m 2 m 3 /h It/h kW kWh/24h Contract STI 125 Indirect 125 0.75 0.5 194 11.3 2 1 266 15.5 2 340 19.8 Comfort STI 125 Indirect 125 0.75 0.
15 MTS (GB) Limited suppor t the initiative. Within the inf or mation pack you will find a cop y of the logbook. It is impor tant that this is completed in the presence of your customer , the y are shown ho w to use it, and it is signed by them.
B 4 5 In order to access the inside of the boiler , it is necessar y to unscrew the f astening screws “A” of the control panel located on the lower part of the panel itself. The control panel mov es downward and when pulled f orward rotates on two lateral hinges .
17 The flue connector has two aper tures, readings can be tak en for the temperature of the comb ustion by-products and of the combustion air , as well as of the concentr ations of O 2 and CO 2 , etc. . T o access these intakes it is necessary to unscrew the front screw and remo ve the metal plate with sealing gasket.
The boiler is fitted with the f ollowing de vices (see section 4.2 for ref erences). 1 - I GNITION F AILURE : This indicates ignition f ailure when a flame is not detected within 7 seconds of star ting an ignition sequence. The L.E.D . “F” will illuminate to signal the shutdown status .
It is recommended that the follo wing inspections be carried out on the boiler at least once a year: 1 - Check the seals f or the water connections; replace any f aulty seals. 2 - Check the gas seals; replace any faulty gas seals . 3 - Visual check of the entire unit.
Manuf acturer : Merloni T ermoSanitari SpA - Italy Commercial subsidiar y: MTS (GB) LIMITED MTS Building Hughenden A venue High Wycombe Bucks HP13 5FT T elephone: (01494) 755600 F ax: (01494) 459775 Inter net: http://www .mtsgb .ltd.uk E-mail: inf o@mtsgb.
デバイスAriston 41-116-05の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Ariston 41-116-05をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAriston 41-116-05の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Ariston 41-116-05の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Ariston 41-116-05で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Ariston 41-116-05を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAriston 41-116-05の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Ariston 41-116-05に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAriston 41-116-05デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。