CAUTION: READ ALL INSTRUCTIONS CAREFULL Y BEFORE INST ALLA TION. SA VE THIS OWNER’S MANUAL FOR FUTURE REFERENCE. Part No. SP6647 12/09 Printed in U.S.A. HD14070 Evaporative Console Humidifier Owner ’ s Manual Model No. HD14070 TM QUARKSP6647 HD14070:SP6647 .
4. Keep the humidifier clean. 5. Do not put foreign objects inside the humidifier . 6. Do not allow to be used as a toy . Close attention is necessary when used by or near children. 7. Never use your humidifier while any part is missing or damaged in any manner .
3 Know Y our Humidifier Description HD14070 Output/24 hrs 14 Gallons/53 Litres Capacity of Bottle 2-3/8 Gallons/9 Litres Sq. Ft. Coverage 2900 Fan Speeds 3 Auto Fan Speed Y es Replacement Filter Set o.
4 How Y our Humidifier W orks Y our new MoistAIR humidifier is designed to satisfy home humidity requirements through the principle of evaporation of water into the air . After water is added to the bottle, the filters begin to soak up the water and become totally saturated in approxi-mately 30 minutes.
5 Location Instructions Step 1: Place humidifier on a flat level surface in an area of your house where humidity is needed most, or in an area which would likely result in moist air being circulated throughout the house, such as near a cold air return.
6 W ater Fill W ARNING : T o reduce the risk of fire or shock hazard, do not pour or spill water into control or motor area. If controls get wet, let them dry completely and have unit checked by authorized service personnel before plugging in. W ARNING: T o reduce the risk of shock, always unplug humidifier before cleaning or servicing.
7 W ater Fill (continued) Each water bottle is designed with a “Side-Fill Cap” that is easily removable. Remove the “Side- Fill Cap” on the side of the water bottle by twisting counterclockwise. Place the opening of the water bottle under a water faucet (the bottle should fit under a four-inch clearance faucet).
8 Operating the Controls Where you set your desired humidity levels depends on your personal comfort level, outside temperature and inside temperature. A starting set point of 30% - 40% ROOM humidity is recommended but there may be conditions that require a different setting.
9 Operating the Controls (continued) Using Y our Humidifier Refill Display Function For maximum run time both bottles should be filled. When both bottles are empty the display alternates the room humidity reading and “F” (FILL), informing additional water is required.
10 Using Y our Humidifier (continued) Check Filter Indicator The ability of any humidifier to efficiently supply humidity output relies heavily on the condition of the filter . As the filter loads with impurities it gradually loses its wicking capability .
11 1. Unplug humidifier before removing the filters. We recommend moving the humidifier to an area where floor coverings are not susceptible to water damage, i.e. kitchen or bath areas. 2. Open the pivoting lid and remove water bottles and set aside. Grasp the fan assembly front center and rear center .
12 T o make cleaning easier , the humidifier cabinet should be empty and completely dried out. T o accomplish this, use the following method: a. On the back side of the humidifier cabinet, find the float retainer . In normal operating mode, the retainer will be positioned in the bottom of the slot in the cabinet.
13 Cleaning and Maintenance (cont’d.) Step 2: T o Remove Parts a. Open the pivoting lid and remove water bottles nd set aside. Grasp the fan assembly front center and rear center . Lift off and set aside on a clean flat surface. The filter housings are now accessible.
14 T roubleshooting CAUTION: Use only EP A Registered Bacteriostat. Use of other water treatment products may damage the filter elements. Under no circumstances should you use water treatment products designed for Roto belt or Ultrasonic humidifiers. Trouble Digital display not illuminated.
15 Repair Parts Parts List for MoistAIR ® Humidifier Model No. HD14070 MD QUARKSP6647 HD14070:SP6647 .qxd 12/10/2009 3:39 PM Page 15.
Key No Part No. Description 1 828741-2 Lid, Stationary 2 828855-2 Lid, Pivoting 3 831680-1 Control Assembly 4 824690 “Side-Fill Cap” 5 828192 Bottle, Left (Includes Key Nos. 4 & 7) 6 828726 Bottle, Right (Includes Key Nos. 4 & 7) 7 509229-1 Cap, V alve Assembly 8 828199-10 Cabinet 9 823726 Rail, Kick 10 STD601 107 Screw , Pan Hd.
17 W arranty Moist AIR ® PRODUCTS HUMIDIFIER W ARRANTY POLICY EFFECTIVE APRIL 1, 2008 SALES RECEIPT REQUIRED AS PROOF OF PURCHASE FOR ALL W ARRANTY CLAIMS . This product is warranted against defects in workmanship and materials for one year from the date of sale except for motors, which are warranted for two years.
c 2009 Part No. SP6647 Form No. SP6647-1 Printed in U.S.A 12/09 Essick Air Products For more information about MoistAIR ® humidifiers, visit our website at www .moistair .com MD ® MD FOR TECHNICAL HELP , CALL (800) 547-3888 FROM USA OR (888) 744-4687 FROM CANADA (Please have complete model number) QUARKSP6647 HD14070:SP6647 .
デバイスMoistAir HD14070の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
MoistAir HD14070をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMoistAir HD14070の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。MoistAir HD14070の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。MoistAir HD14070で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
MoistAir HD14070を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMoistAir HD14070の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、MoistAir HD14070に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMoistAir HD14070デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。