Monessen HearthメーカーBTU/Hrの使用説明書/サービス説明書
ページ先へ移動 of 32
W arning: This is an unvented gas- fired heater . It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. See page 8. This appliance may be installed in an aftermarket, permanently located, manuf actu red ( mobile ) hom e, wh ere not prohibited by local codes.
2 49D0090 49D0090 3 CONTENTS Important Safety Information .......................... 3 Specifications ................................................... 5 Local Codes ...................................................... 5 Product Identification ...
2 49D0090 49D0090 3 INST ALLER Please leav e these instructions with the o wner . OWNER Please retain these instructions for future reference . IMPORT ANT Read this owner’s manual carefully and completely before trying to assemble, operate, or service this heater .
4 49D0090 49D0090 5 IMPORT ANT SAFETY INFORMA TION Continued fr om page 3 10. Thi s appl ianc e is onl y for use wit h the ty pe of g as ind icat ed on the rating plate. This appliance is not con vertible for use with other gases. 11. Do not place propane/LP supply tank(s) inside an y struc- ture.
4 49D0090 49D0090 5 NA TURAL GAS NOTE: An external regulator is required to reduce supply pressure to a maximum of 10 1 / 2 " W .C. on natural gas systems operating at higher pressure. Thermostat Pressur e Regulator Pressure Setting: 4" w .c.
6 49D0090 49D0090 7 PRODUCT IDENTIFICA TION AND ASSEMBL Y Figure 1 - V ent-Free Gas Log Space Heater SAFETY DEVICE Th is he ate r ha s a pi lot with an O xyg en De ple tio n Se nsi ng (OD S) s afet y shu tof f syst em. Th e ODS /pil ot i s a req uir ed feature for vent-free room heaters.
6 49D0090 49D0090 7 ASSEMBL Y INST ALLING LOGS NOTE: For easier installation, lay heater on its back. 1. Slide screen up to remov e. 2. Remov e log from inside of base. Discard protecti ve packag- ing. 3. Gently slide log on log retaining pin on base assembly (see Figure 3) .
8 49D0090 49D0090 9 FRESH AIR FOR COMBUSTION AND VENTILA TION W ARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air .
8 49D0090 49D0090 9 FRESH AIR FOR COMBUSTION AND VENTILA TION DETERMINING FRESH-AIR FLOW FOR HEA TER LOCA TION DETERMINING IF YOU HA VE A CONFINED OR UNCONFINED SP ACE Use this worksheet to determine if you ha ve a conned or unconned space.
10 49D0090 49D0090 1 1 V entilated Crawl Space Inlet Air Outlet Air Outlet Air Outlet Air V entilated Attic T o Attic T o Crawl Space FRESH AIR FOR COMBUSTION AND VENTILA TION VENTILA TION AIR FROM INSIDE BUILDING This fresh air would come from an adjoining unconfined space.
10 49D0090 49D0090 1 1 INST ALLA TION This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’ s circulating blower while using heater .
12 49D0090 49D0090 13 .
12 49D0090 49D0090 13 Never install the heater • in a bedroom or a bathroom • in a recreational vehicle • where curtains, fu rni tu re, cl ot hin g, or oth er fl amm ab le objects are less than .
14 49D0090 49D0090 15 .
14 49D0090 49D0090 15 Continued B. MOUNTING HEA TER ON OPTIONAL HEARTH BASE T ools needed: • #2 Phillips scre wdriv er • slotted scre wdriv er • electric drill (if securing base to oor) The o.
16 49D0090 49D0090 17 Shipping Screw Bottom of Heater Holes for Securing Heater to Floor Mounting Holes Sheet Metal Screws INST ALLA TION Continued Securing Hearth Base to Floor 1. Position hearth base in desired location. Mark hol es for drilling (See Figure 11) .
16 49D0090 49D0090 17 INST ALLA TION Use only new , black iron or steel pipe. Internally- tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1 / 2 " or greater diameter to allow proper gas volume to heater . If pipe is too small, undue loss of pressure will occur .
18 49D0090 49D0090 19 Figure 15 - Equipment Shutoff V alve Open Closed Equipment Shutoff V alve Propane/LP Supply T ank Thermostat Gas V alve Location Equipment Sutoff V alve Pressure T esting Gas Supply Piping System T est Pressures In Excess Of 1 / 2 PSIG (3.
18 49D0090 49D0090 19 OPERA TING INSTRUCTIONS A. This appli ance is equip ped with an ignit ion de vice which automatically lights the pilot. If the piezo is not working properly , see “Match Lighting Instructions, ” page 21. B. BEF OR E OP ERA TIN G sm ell al l ar oun d t he a ppl i- ance area for gas.
20 49D0090 49D0090 21 OPERA TING INSTRUCTIONS 1. STOP! Read the safety information label. 2. Make sure the manual shutof f valv e is fully open. 3. This gas log set is equipped with an ignition de vice (piezo) which automatically lights the pilot.
20 49D0090 49D0090 21 T O TURN OFF GAS T O HEA TER SHUTTING OFF HEA TER 1. T urn control knob clockwise to OFF position to completely shut off the heater . 2. If applicable: T urn off all electric po wer to the heater . SHUTTING OFF BURNER ONL Y (PILOT ST A YS LIT) T urn control knob clockwise to the PILO T position.
22 49D0090 49D0090 23 INSPECTING HEA TER Check pilot ame pattern and burner ame pattern often. PILOT FLAME P A TTERN Figure 20 sho ws a correct pilot ame pattern. Figure 21 sho ws an incorrect pilot ame pattern. The incorrect pilot ame is not touching the thermocouple.
22 49D0090 49D0090 23 TROUBLESHOOTING REMEDY 1. Replace pilot 2. Replace pilot 3. Reconnect ignitor cable 4. Free ignitor cable if pinched by any metal or tubing. K eep ignitor cable dry 5. Replace ignitor cable 6. Replace piezo ignitor 1. T urn on gas supply or open equipment shutof f valv e 2.
24 49D0090 49D0090 25 TROUBLESHOOTING REMEDY 1. Clean burner (see “Cleaning and Mainte- nance,” page 26) or replace burner orice 2. Replace burner orice 3. Contact local gas company 1. Contact local gas company 2. Clean burner (see “Cleaning and Mainte- nance,” page 26) or replace burner orice 1.
24 49D0090 49D0090 25 If you smell gas • Shut off gas supply . • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immed iately ca ll your ga s supplie r from a ne ighbor ’ s pho ne.
26 49D0090 49D0090 27 Figure 24 - Injector Holder On Outlet Burner Tube Primary Air Inlet Hole Ports/Slots Injector Holder Burner T ube CLEANING AND MAINTENANCE Y ou must keep control areas, burner , and circulating air passageways of heater clean. In spe ct the se are as of hea ter be for e e ach us e.
26 49D0090 49D0090 27 ILLUSTRA TED P ARTS LIST Failure to position the parts in accordance with these diagrams or failure to use only parts specifically a p p r o v e d wi t h t h i s a p p l i a n c e m a y result in property damage or personal injury .
28 49D0090 49D0090 29 ACCESSORIES Hearth Base HHB Brass Louvers LBHH BRASS LOUVERS - LBHH Polished brass louvers — tw o (2) top and three (3) bottom HEARTH BASE - HHB For locating heater on the oor . Includes brass trim. Complete installation instructions included.
28 49D0090 49D0090 29 ACCESSORIES THERMOST A T FORCED AIR BLOWER - BLOHH Provides better heat distribution. Makes heater more efcient. Compete installation and operating instructions included.
30 49D0090 49D0090 31 NOTES.
30 49D0090 49D0090 31 NOTES.
May 2002 P/N 49D0090 • Rev . 1 MONESSEN HEAR TH SYSTEMS LIMITED LIFETIME W ARRANTY POLICY LIFETIME W ARRANTY The follo wing components are warranted for life to the original o wner , subject to proof of purchase: Firebox, Combustion Chamber , Heat Exchanger , Grate and Stainless Steel Burners.
デバイスMonessen Hearth BTU/Hrの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Monessen Hearth BTU/Hrをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMonessen Hearth BTU/Hrの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Monessen Hearth BTU/Hrの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Monessen Hearth BTU/Hrで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Monessen Hearth BTU/Hrを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMonessen Hearth BTU/Hrの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Monessen Hearth BTU/Hrに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMonessen Hearth BTU/Hrデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。