Monessen HearthメーカーM400BFCの使用説明書/サービス説明書
ページ先へ移動 of 24
647 BFC cover 8/18/00 djt M400BFC Balanced Flue (Closed Combustion) Heat-Circulating Fireplace For use in the U.S. / Canada Underwriter ’s Laboratories Report No.
2 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 M400BFC Listed UL127 / ULC-S610 Standard for Factory Built Fireplaces Safety Information ...................................................................................... 3 Specifications and Framing .
3 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Safety Information Please Read This Manual Before Installing and Using Fireplace IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instruc- tions may result in a possible fire hazard and will void the warranty .
4 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 M400BFC Balanced Flue Heat-Circulating Fireplace Fig. 1 M400BFC specifications and framing. 6 " (16mm) 56O " (13mm) 56O ".
5 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 FP554a BFC Fireplace and chase parts identification circulating model 8/21/00 djt T ermination Cap Storm Collar Pan Flashing Draftstop Stando.
6 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 D Rise B G H B Offset C E 6 FT . G H A Hearth Floor Chimney Section CHIMNEY FLUE EXIT Elbow FP269 MBUF 5/16/96 rev . 5/25 TCS8A Support Example 1 Example 2 Example 3 Chimney Requirements - Offset Installations Notes: G + H cannot exceed 20 feet.
7 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Planning Information Preplanning an installation is very important to ensure safety and to save time and money . An installer must predetermine where a fireplace will be set and how the chimney system will be run.
8 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30’ (9 m) above the hearth. Chimney supports are required if the vertical height exceeds 30’ (9 m).
9 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 FPC555a Platform insulation BFC model 8/21/00 djt Hard Flat Surface Insulation Platform FPC555a Fig.
10 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Offset Installation In order to clear an obstruction, it may be necessary to offset chimney from vertical. This is accomplished by using elbows. Use the 30° Offset Elbow table on Page 5 to determine proper offset and parts required.
1 1 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Positioning, Safety Strips, Securing the Fireplace Slide fireplace into position. Lift the fireplace front slightly and slide the metal safety strips under front bottom edge about 1 Zx ” (38 mm), allowing the remainder to extend in front of firebox.
12 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Installing the Chimney System Start by attaching the first chimney section to the collar on top of the fireplace. Install the pipe as pictured in Figure 14. When you get a good lock, you will hear the pipe clearly snap together .
13 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Firestop spacers are not available for , nor are they required on vertical walls. DO NOT put any sealant around the area where the outer pipe slides through the firestop spacer . If you seal this area, it may cause a fire hazard.
14 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 FRONT VIEW SIDE VIEW Air Space Clearances FPC559a BFC AIR SP ACES circulating models 8/21/00 djt Standoff Combustible framing material MUST NOT penetrate AIR SP ACE (shaded areas).
15 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 MA81 rev. 8/5/97 1 Zx " Ref. B C Combustible materials are permitted within a shaded area shown in Figure 21 titled Minimum W all Clearances. * * * MA81 Fig. 20 Combustible mantel clearances.
16 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Side W all Protection Adjacent combustible side walls that are within mini- mum dimensions shown in Figure 24 of the fireplace opening must be protected with MHSC W all Shield Model SP40 or a specifically built wall shield described in Figure 18.
17 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 W ARNING: Hearth extension must be installed in accordance with Figure 23 and must not cover the bottom front opening of the circulating model.
18 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Installing Line for Gas Logs MHSC fireplaces are designed to accept a 1/2” (13 mm) gas line for installation of an approved gas appliance. (MHSC manufactures a wide variety of gas logs for use in MHSC fireplaces.
19 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 647 BFC parts 2008 2/08 djt 1 2 3 5 6 7 8 9 10 1 1 12 13 14 16 15 19 18 17 4 24 20 22 21 25 23 23 26 27 28 29 MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
20 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 M400BFC Balanced Flue Fireplace (continued) 17. Blower Assembly - FKSX-A 20000620 18. Grate Retainer 2353179 19. Junction Box Assembly 3126161 20. Ceramic Glass Panel (two per fireplace) 30004352 21.
21 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 The following accessories for this appliance are available from your local Monessen distributor . Should you need ad- ditional information beyond what your distributor can furnish, contact: MHSC, 149 Cleveland Drive, Paris, KY 40361, Attn: T echnical Services.
22 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Chimney Components Component Description Model Number Chimney Support Used to support chimney for each of TCS8A 30’ vertical height and 6.
23 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 LIMITED W ARRANTY Factory-Build Fireplace and Components (Except Blowers) What is Covered and For How Long Five-Y ear Coverage: For five yea.
MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www .mhsc.com.
デバイスMonessen Hearth M400BFCの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Monessen Hearth M400BFCをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMonessen Hearth M400BFCの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Monessen Hearth M400BFCの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Monessen Hearth M400BFCで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Monessen Hearth M400BFCを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMonessen Hearth M400BFCの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Monessen Hearth M400BFCに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMonessen Hearth M400BFCデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。