Mustang SurvivalメーカーMD1250の使用説明書/サービス説明書
ページ先へ移動 of 16
MD12 50 T A CTIC AL INFLA T ABLE SIDE POUCH LP.
DO NO T REMO VE PRIOR T O S ALE Warning: This document is for the use of licensed users only . No part of this document may be reproduced, transmitted, or transcribed in any form or by any means without the express permission of Mustang Survival Corp.
C ONTENTS Introduction ................................................................................................... 1 Product Familiarization and Readiness ....................................................... 2 Readiness Checklist ..........
INTRODUCTION This manual provides instructions and guidelines for safely using and maintaining Mustang Survival MD1250 T actical Inflatable Side Pouch Life Preservers (LPs). The MD1250 LP provides flotation capability with minimum bulk or interference using separate, independently operated left and right LPs.
PRODUCT F AMILIARIZA TION AND READINESS The MD1250 T actical Inflatable Side Pouch LPs are used in right/left pairs, and can be attached to an LE belt, or integrated P ALS webbing and MOLLE vest. Right-hand LPs have the letter R on the attachment webbing straps (Figure 2); left-hand LPs have the letter L.
R eadiness Checklis t If the inflat or expiry date has p assed, Must ang Survival r ecommends wat er te sting the MD1250 LP t o become familiar with it s in-wat er functionality . When all boxes are checked, the LP is ready for use: F Status indicator is green.
2. Release the attachment webbing straps on the back of the LP by pulling up on each strap just below the bottom edge of the pull-the-dot snap. 3. Feed the attachment webbing straps on the back of the LP through the P ALS webbing. 4. Reattach the pull-the-dot snaps by pushing down on the top edge of the snap opposite the dot.
4. Release the mouthpiece, and turn the locking ring counterclockwise to close the inflator valve and lock the mouthpiece in place. DONNING THE INFLA TED LP Once the LPs have been inflated through manual, automatic, or oral inflation, tuck the inflated cells underneath each arm (Figure 6).
4. Release the mouthpiece, and turn the locking ring counterclockwise to close the inflator valve and lock the mouthpiece in place. 5. Complete repacking of the LP – see Repacking the LP . RE - ARMING THE LP CA UTION: The MD 12 50 LP must be deflat ed befor e being re-armed.
12. Ensure that the status indicator on the replacement inflator cap is green, the lanyard for the beaded manual inflation handle is present, and the locking ring is locked. 13. T o test for leakage, inflate the LP using the oral inflator tube – see Inflating the LP .
10. Ensure the bladder fabric is wrapped tightly around the CO 2 cylinder and the hydrostatic inflator (Figures 14–16). 11. Remove the vacuum fitting from the oral inflation tube. 12. Detach the automatic/manual conversion cap (MA7219) from the hydrostatic inflator .
Final P acking 1. Ensure the opening in the cover fabric is secured around the hydrostatic inflator . The water inlet valve should be easily accessible.
• Visually inspect the expiry date on the hydrostatic inflator . If the expiry date has passed, replace the inflator – see Re-arming the LP . T esting f or Leak s Perform this test every 180 days, or more frequently if the LP is exposed to extreme conditions.
T esting the A utomatic In flat or NO TE: A left/ right pair of fully armed MD12 50 LPs and t wo MA7 214 -10 re- arm kits are requir ed for this t est. 1. Attach the LPs to the left and right sides (see W earing the LP). 2. Enter water of an appropriate depth to keep the head above the surface.
A CCE SS ORIES MA7214-10 Re-Arm Kit: 33 gram CO 2 replacement cylinder and inflator cap (two kits required for each pair of MD1250 LPs) MA7219 Auto/Manual Conversion Cap GLOSSARY T erm Definition LP L.
Mustang Survival and seahorse design is a register ed trademark of Mustang Survival Corp. Our commitment to quality has earned our Bur naby facilities ISO 9001 registration, the highest of all international standards. This is our guarantee you are r eceiving the ultimate in design and manufacturing.
デバイスMustang Survival MD1250の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Mustang Survival MD1250をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMustang Survival MD1250の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Mustang Survival MD1250の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Mustang Survival MD1250で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Mustang Survival MD1250を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMustang Survival MD1250の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Mustang Survival MD1250に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMustang Survival MD1250デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。