NapoleonメーカーCastlemore GDS26Nの使用説明書/サービス説明書
ページ先へ移動 of 32
1 W415-0607 / A / 01.18.08 $10.00 CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL ST ANDARDS: ANSI Z21.88 • CSA 2.33 FOR VENTED GAS FIREPLACE HEA TERS. INST ALLA TION AND OPERA TION INSTRUCTIONS Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .
2 W415-0607 / A / 01.18.08 • Do not burn wood or other materials in this stove. • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the stove.
3 W415-0607 / A / 01.18.08 NAPOLEON® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Cer tifi cate. NAPOLEON® products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0607 / A / 01.18.08 FOR YOUR SATISFACTION, THIS STOVE HAS BEEN TEST- FIRED TO ASSURE ITS OPERATION AND QUALITY! Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 1 1 inches water column for propane. Maximum inlet gas pressure is 7 inches water column for natural gas and 13 inches water column for propane.
5 W415-0607 / A / 01.18.08 35 1 / 2 ” 37” 18 1 / 8 ” 23 5 / 8 ” 4” DIA. 7” DIA. GAS LINE ACCESS ELECTRICAL ACCESS 29 1 / 8 ” DIMENSIONS FIGURE 1a VENTING VENTING LENGTHS AND AIR TERMINAL L OCA TIONS Use only Wolf Steel, Simpson Dura-V ent, Selkirk Direct T emp or American Metal Amerivent venting components.
6 W415-0607 / A / 01.18.08 16” MINIMUM 40 FT MAXIMUM 3 FT MINIMUM 16” MINIMUM 40 FT MAXIMUM 3 FT MINIMUM TYPICAL VENT INST ALLA TIONS FIGURE 2a FIGURE 3a * Refer to "V enting" Section The maximum vent length for a corner installation is 20" of horizontal run, in addition to the 45° offset.
7 W415-0607 / A / 01.18.08 FIGURE 6 MINIMUM AIR TERMINAL L OCA TION CLEARANCES.
8 W415-0607 / A / 01.18.08 VENTING APPLICA TION FL O W CHART STOVE VENT EXIT REAR EXIT TOP EXIT Horizontal T ermination V ertical T ermination V ertical T ermination V ertical rise is equal to or grea.
9 W415-0607 / A / 01.18.08 90° 90° 90° H 1 V 2 H 2 V 1 Simple venting con fi guration (only one 90° elbow) For vent con fi gurations requiring more than one 90° elbow , the following formulas apply: F or mula 1: H T < V T F or mula 2: H T + V T < 40 feet Example 1: V 1 = 3 ft V 2 = 8 ft V T = V 1 + V 2 = 3 + 8 = 1 1 ft H 1 = 2.
10 W415-0607 / A / 01.18.08 V 2 90° H 3 H 1 90° H 2 H 1 V 1 Simple venting con fi guration (only one 90° elbow) Example 2: V 1 = V T = 6 ft H 1 = 3 ft H 2 = 5 ft H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .03(two 90° elbows - 90°) = .03(180° - 90°) = 2.
11 W415-0607 / A / 01.18.08 See graph to determine the required vertical rise V T for the required horizontal run H T For vent con fi gurations requiring more than two 90° elbows the following formu.
12 W415-0607 / A / 01.18.08 V 1 V 2 90° 45° 90° 90° Simple venting con fi guration (only two 90° elbows) Example 5: V 1 = 4 ft V 2 = 1.5 ft V T = V 1 + V 2 = 4 + 1.5 = 5.5 ft H 1 = 2 ft H 2 = 1 ft H 3 = 1 ft H 4 = 1.5 ft H R = H 1 + H 2 + H 3 + H 4 = 2 + 1 + 1 + 1.
13 W415-0607 / A / 01.18.08 REQUIRED VER TICAL RISE IN FEET V T HORIZONT AL VENT RUN PLUS OFFSET IN FEET H T The shaded area within the lines represents acceptable values for H T and V T . Example 6: V 1 = 5 ft V 2 = 6 ft V 3 = 10 ft V T = V 1 + V 2 + V 3 = 5 + 6 + 10 = 21 ft H 1 = 8 ft H 2 = 2.
14 W415-0607 / A / 01.18.08 VERTICAL THR OUGH EXISTING CHIMNEY This appliance is designed to be attached to a 3" co-linear fl exible vent system running the full length of a masonry chimney .
15 W415-0607 / A / 01.18.08 REAR EXIT CONVERSION FIGURE 19 4” Gasket 7” Cover Plate 7” Gasket 4” Gasket 4” Collar 7” Gasket 7” Collar Outer T op 4” Cover Plate In order to convert the .
16 W415-0607 / A / 01.18.08 1. Determine the air terminal location, cut and frame a 9" square opening in the ceiling and the roof to provide the minimum 1" clearance between the vent pipe / liner and any combustible material. T ry to center the vent pipe location midway between two joists to prevent having to cut them.
17 W415-0607 / A / 01.18.08 SCREWS & W ASHERS 4" COUPLER SELF DRILLING #8x1/2" 7" RIGID VENT PIPE SEALANT HIGH TEMPERA TURE 4" FLEXIBLE VENT PIPE 7" RIGID VENT PIPE 1. Attach the telescopic sleeve to the last section of 7" rigid vent pipe.
18 W415-0607 / A / 01.18.08 RESTRICTING VERTICAL VENTS V ertical termination installations exiting either from the rear or the top flue collar of the stove may display a very active flame.
19 W415-0607 / A / 01.18.08 FIGURE 30 FIGURE 31 RESTRICTOR PLA TE 1. Remove the front and the door from the stove. 2. Remove the screws securing the baf fl e plate. Figure 31 . Note: The baf fl e rests on two screws that are attached to the back of the fi rebox.
20 W415-0607 / A / 01.18.08 FIGURE 34 MINIMUM MANTEL, SHELF OR CEILING CLEARANCES 1” 2” 47 1 / 2 ” 35 1 / 2 ” 5” BRICK COMBUSTIBLE NON-COMBUSTIBLE 29 1 / 8 ” MINIMUM PLUS RISE * 0” IF NON-COMBUSTIBLE FINISHING IS USED SUCH AS BRICK AND STONE.
21 W415-0607 / A / 01.18.08 BL O WER INST ALLA TION ELECTRICAL INST ALLA TION TO BE DONE BY A QUALIFIED INST ALLER and must be connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the current ANSI/NFP A 70 NA TIONAL ELECTRICAL CODE in the United States.
22 W415-0607 / A / 01.18.08 90° FINISHING GLASS DOOR INST ALLA TION AND REMO V AL 1. Lift the top cast piece off of the unit. 2. Pull handle forward and rotate 90º to unlatch the door .
23 W415-0607 / A / 01.18.08 1. Place the rear log as shown, ensuring the holes on the underside are placed onto the 2 pins of the log support. In order to assemble the log set, the glass door must be removed, see Glass Door Installation and Removal in the FINISHING section of this manual.
24 W415-0607 / A / 01.18.08 FIGURE 46 B A TTERY H OLDER G AS V AL VE P ILOT A SSEMBL Y I GNITION M ODULE P ILOT G AS L INE Orange (I) [through independent conduit] Yellow (S) [through Gas line conduit.
25 W415-0607 / A / 01.18.08 1. ST OP! READ THE ABOVE SAFETY INFORMA TION ON THIS LABEL. 2. TURN REMOTE W ALL SWITCH T O OFF POSITION. 3. TURN OFF ALL ELECTRIC POWER TO THE STOVE AND REMOVE BA TTERIES. 4. THIS ST OVE IS EQUIPPED WITH AN IGNITION DEVICE WHICH AUTOMA TICALL Y LIGHTS THE PILOT .
26 W415-0607 / A / 01.18.08 NOTE: Check and adjust, if necessary , the primary air to 7 / 16 ” for propane and 1 / 4 ” for natural gas. Replace the screws. 7. T urn on the gas supply and check for gas leaks by brushing on a soap and water solution.
27 W415-0607 / A / 01.18.08 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon® d ealer or distributor. When ordering replacement parts always give the following information: 1.
28 W415-0607 / A / 01.18.08 ATTE NTION-C HAUD CAUTION - HOT 27 44 35 18 6 7 46 17 5 11 1 3 2 23 8 26 29 31 32 34 34 28 34 25 24 33 41 38 37 40 39 21 16 4.
29 W415-0607 / A / 01.18.08 Pilot will not light. V erify the "S" wire for the sensor and the "I" wire for the ignitor are connected to the correct terminals (not reverse) on the module and pilot assembly . V erify no loose connections, electrical shorts in the wiring or ground out to any metal object.
30 W415-0607 / A / 01.18.08 Flames are very ag- gressive. - V enting action is too great. T ighten door clamps Restrict vent exit with restrictor plate. See Restricting V ents. - Door is ajar Main burner fl ame is a blue, lazy , transparent fl ame. - Blockage in vent.
31 W415-0607 / A / 01.18.08 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Deale.
32 W415-0607 / A / 01.18.08 NO TES.
デバイスNapoleon Castlemore GDS26Nの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Napoleon Castlemore GDS26Nをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNapoleon Castlemore GDS26Nの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Napoleon Castlemore GDS26Nの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Napoleon Castlemore GDS26Nで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Napoleon Castlemore GDS26Nを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNapoleon Castlemore GDS26Nの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Napoleon Castlemore GDS26Nに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNapoleon Castlemore GDS26Nデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。