1 W415-0533 / E / 02.09.06 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.
2 W415-0533 / E / 02.09.06 WARNING • Do not burn wood or other ma terials in this f ir eplace . • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
3 W415-0533 / E / 02.09.06 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. PATENTS U.S. 5.303.693.801 - CAN. 2.073.41 1, 2.082.915.
4 W415-0533 / E / 02.09.06 THIS GAS FIREPLACE SHOULD BE INST ALLED AND SERV - ICED BY A QUALIFIED INST ALLER to conform with local codes. In absence of local codes, install the BG D42 to the current Na- tional Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes.
5 W415-0533 / E / 02.09.06 Use only Wolf S teel, Simp son Dura-V ent, Selkirk Direct Temp or American Metal Amerivent venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air terminal locations for ei- ther system are set out in this manual and must be ad- hered to.
6 W415-0533 / E / 02.09.06 * Recommended to prevent condensation on windows and thermal breakage ** Using a Napoleon soffit heat shield, W585-0096, or equivalent, the distance may be reduced to a minimum of 18". It is recommended to maximize the distance to vinyl clad soffits.
7 W415-0533 / E / 02.09.06 Use the GD401 periscope kit to locate the air termination above grade. The periscope must be installed so that when final grading is completed, the bottom air slot is located a minimum of 12 inches above grade. The maximum allow- able vent length depends on the fireplace, as illustrated.
8 W415-0533 / E / 02.09.06 VERTI C AL TERMINA TION HORIZONT AL TERMINA TION vertical rise is equal to or greater than the horizontal run horizontal run + verti- cal rise to maximum of 40 feet vertical.
9 W415-0533 / E / 02.09.06 ELBO W VENT LENGTH V AL UES DEFINITIONS HORIZONT AL TERMINA TION REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFFSETS IN FEET (H T ) FIGURE 5 .
10 W415-0533 / E / 02.09.06 V 1 HORIZONT AL TERMIN A TION See graph to determine the re- quired vertical rise V T for the re- quired horizontal run H T . For vent configurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.
11 W415-0533 / E / 02.09.06 90° 90° V 1 H 1 H 2 V 2 45° 90° 45° VERTICAL TERMIN A TION Example 3: V 1 =5 f t V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 =3 f t H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .
12 W415-0533 / E / 02.09.06 H 1 VERTICAL TERMIN A TION For vent configurations requiring more than one 45º and one 90° elbow , the following formulas apply: F or mula 1: H T < 3V T F or mula 2: H.
13 W415-0533 / E / 02.09.06 This application occurs when venting through a roof. Installation kits for various roof pitches are available from your Napo- leon dealer .
14 W415-0533 / E / 02.09.06 AIR TERMINAL CONNECTOR INNER FLEX LINER OUTER FLEX LINER INNER SLEEVE HIGH TEMPERA TURE SEALANT ROOF SUPPORT FIGURE 18 A VENT SHIELD MUST BE USED IF THE W ALL TERMINAL IS INST ALLED ON COMBUSTIBLE, EXTERIOR SURF ACES. 1. Cut or frame a hole in an exterior wall with a minimum round or square opening of 10½ inches.
15 W415-0533 / E / 02.09.06 STORM COLLAR FLASHING CAULKING WEATHE R SEALA NT 2” AIR INL ET BASE FIGURE 25 The vent system must be supported approximately every 3 feet for both vertical and horizontal runs.
16 W415-0533 / E / 02.09.06 V ertical terminations may display a very active flame. As this appearance is not desirable, the vent exit must be restricted using restrictor plate, W500-0205. This reduces the velocity of the exhaust gases, slowing down the flame pattern and creating a more traditional appearance.
17 W415-0533 / E / 02.09.06 It is best to frame your fireplace after it is positioned and the vent system is installed. Use 2x4's and frame to local building codes. FIGURES 31-33. It is not necessary to install a hearth extension with this fireplace system.
18 W415-0533 / E / 02.09.06 NAILING TA B 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws supplied. Secure through the centre of the top and bottom slots in the nailing tab and then through the existing holes in the corner posts.
19 W415-0533 / E / 02.09.06 TO INST ALL THE UPPER L OUVRES: Insert the upper louvres into the slots on both brackets. TO INST ALL THE L OWER L OUVRE ASSEMBL Y: At- tach each hinge to the fire- bo x with 2 screws. Position the hinge screen into place and with the con- trol door open, secure to the firebox using three screws.
20 W415-0533 / E / 02.09.06 3. T ear the glowing embers into pieces and place along the front row of ports covering all of the burner area in front of the small logs (#2 & #3). Care should be taken to shred the embers into thin, small irregular pieces as only the exposed edges of the fibre hairs will glow .
21 W415-0533 / E / 02.09.06 INST ALLA TION T O BE DONE BY A QUALIFIED IN- ST ALLER and must be electrically con- nected and grounded in accord- ance with local codes.
22 W415-0533 / E / 02.09.06 ELECTRICAL INST ALLA TION T O BE DONE BY A QUALI- FIED INST ALLER and must be connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 C ANADIAN ELECTRICAL CODE in Canada or the ANSI/NFP A 70 NA TIONAL ELECTRICAL CODE in the United S tates.
23 W415-0533 / E / 02.09.06 • Turn off all gas to the fireplace. • Open windows. • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour's phone.
24 W415-0533 / E / 02.09.06 Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow . Air shutters have been factory set open according to the chart below: These settings are for the maximum horizontal vent run.
25 W415-0533 / E / 02.09.06 # P ART NO . DESCRIPTION 1 W357-0001 PIEZO IGNITER 2 W680-0004 THERMOPILE 3 W680-0005 THERMOCOUPLE 4 W010-0800 N A TUR AL GAS PILOT ASSEMBL Y 4 W010-0801 PROPANE GAS PILOT .
26 W415-0533 / E / 02.09.06.
27 W415-0533 / E / 02.09.06 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor . - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed.
28 W415-0533 / E / 02.09.06 Pilot goes out while standing; Main burner is in 'OFF' position. Gas piping is undersized. - turn on all gas appliances and see if pilot flame flutters, dimin- ishes or extinguishes, especially when main burner ignites.
デバイスNapoleon Fireplaces BGD42Nの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Napoleon Fireplaces BGD42Nをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNapoleon Fireplaces BGD42Nの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Napoleon Fireplaces BGD42Nの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Napoleon Fireplaces BGD42Nで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Napoleon Fireplaces BGD42Nを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNapoleon Fireplaces BGD42Nの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Napoleon Fireplaces BGD42Nに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNapoleon Fireplaces BGD42Nデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。