1 W415-0319 / E / 01.17.07.
2 W415-0319 / E / 01.17.07 Hood Louvre Bracket Hinge Screen Louvre Installation & Removal Heat Shield S tand Off Removal Logo Placement 16-17 OPTIONS Patented Catalytic Glass Door Blower Installat.
3 W415-0319 / E / 01.17.07 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in t heir work.
4 W415-0319 / E / 01.17.07 This fireplace may be installed in an aftermarket per- manently located, manufactured (mobile) home, where not pr ohibited by local codes . This fireplace is only for use with the type of gas indi- cated on the r a ting plate .
5 W415-0319 / E / 01.17.07 This heater shall not be installed in a confined space or unusually tight construction unless pro- visions are provided for adequate combustion and ventila tion air .
6 W415-0319 / E / 01.17.07 50 If in this example a solid door separates Room 1 from Room 2, the volume of Room 2 could not be used. In this case the maximum BTU/h would be: Maximum BTU/h: 800 x 1000 =.
7 W415-0319 / E / 01.17.07 FIGURES 4 a-d PENINSULA OPEN-END SEE-THRU 4-SIDED.
8 W415-0319 / E / 01.17.07 Note: In order to avoid the possibility of exposed insula- tion or vapour barrier coming in contact with the fireplace body , it is recommended that the walls of the fireplace enclosure be “finished” (ie: drywall/sheetrock), as you would finish any other outside wall of a home.
9 W415-0319 / E / 01.17.07 Combustible materials may be installed flush with the front of the fireplace but must not cover any of the black face- areas of the fireplace. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas.
10 W415-0319 / E / 01.17.07 FIGURE 14 Note: In order to avoid the possibility of exposed insula- tion or vapour barrier coming in contact with the fireplace body , it is recommended that the walls of the fireplace enclosure be “finished” (ie: drywall/sheetrock), as you would finish any other outside wall of a home.
11 W415-0319 / E / 01.17.07 Install the base panels as illustrated in steps 1-4 on page 9. Both side panels sit under the bracket tab . Holding the side panel in position, bend down the tab to secure.
12 W415-0319 / E / 01.17.07 Combustible materials may be installed flush with the front of the fireplace but must not cover any of the black face- areas of the fireplace. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas.
13 W415-0319 / E / 01.17.07 PHAZER TM logs, glowing and charcoal embers, exclusive to Napoleon fireplaces, provide a unique and realistic glow- ing effect that is dif ferent in every installation. T ake the time to carefully position the embers for a maximum glowing effect.
14 W415-0319 / E / 01.17.07 The curtain mesh must be kept fully closed during opera- tion to help prevent accidental burns from occurring. The heater must not be used when the hood is re- moved. Hook the hood over the lip of the curtain support plate.
15 W415-0319 / E / 01.17.07 L36 L OUVRE INST ALLA TION FIGURE 32 a-c HOOD Attach the hood by pressing the top flange into the clips along the top of the louvre opening. Secure using a screw through the centre slot. LOWER LOUVRES Insert the hinge clips into the slots located at the bottom left and right corners of the unit.
16 W415-0319 / E / 01.17.07 Notes: Ornamental insets can not be used in conjunction with the catalytic door When using a catalytic door , glassed doors must be used on all other side or end openings. This unique patented catalytic system was designed to provide unparalleled safety and peace of mind.
17 W415-0319 / E / 01.17.07 Remove the thermodisc bracket from the top of the firebox. Remove the thermodisc from the bracket supplied in the blower kit and install the thermodisc into the fireplace bracket. Then replace the bracket in the location it was removed.
18 W415-0319 / E / 01.17.07 When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob is depressed. 1. STOP! Read the above safety information on this la- bel. 2. Set the thermostat to lowest setting. 3. Turn off all electric power to the fireplace.
19 W415-0319 / E / 01.17.07 THIS PROCEDURE MUST BE PERFORMED BY A QU ALIFIED SERVICE PERSON! Inspect the pilot for any visible contamination or debris (usually lint, pet hair , spider webs, carpet fibre, etc.) and remove. Disconnect the pilot from the pilot tubing line.
20 W415-0319 / E / 01.17.07 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor .
21 W415-0319 / E / 01.17.07.
22 W415-0319 / E / 01.17.07 Main burner goes out; pilot stays on. Pilot flame is not large enough or not engulfing the thermopile - service or replace Oxygen Depletion Sensor System - correct piping and/or regulator to provide correct pressure Thermopile shorting - clean thermopile connection to the valve.
23 W415-0319 / E / 01.17.07 White / grey film forms on the glass of the optional cata- lytic door . Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a recommended gas fireplace glass cleaner .
24 W415-0319 / E / 01.17.07 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Deale.
デバイスNapoleon Fireplaces fireplacesの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Napoleon Fireplaces fireplacesをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNapoleon Fireplaces fireplacesの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Napoleon Fireplaces fireplacesの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Napoleon Fireplaces fireplacesで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Napoleon Fireplaces fireplacesを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNapoleon Fireplaces fireplacesの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Napoleon Fireplaces fireplacesに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNapoleon Fireplaces fireplacesデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。