Napoleon FireplacesメーカーGD80NTの使用説明書/サービス説明書
ページ先へ移動 of 28
1 W415-0447 / B / 05.24.05 W415-0447 / B / 05.24.05.
2 W415-0447 / B / 05.24.05 WHA T T O DO IF Y OU SMELL GAS WARNINGS & SAFETY PRECA UTIONS.
3 W415-0447 / B / 05.24.05 PG2-6 INTR ODUCTION W arnings and Safety Precautions W arranty Dimensions General Instructions General Information Care of Glass & Plated Parts 6- 11 VENTING V ent lengt.
4 W415-0447 / B / 05.24.05 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. PA TENTS U.S. 5.303.693.801 - CAN. 2.073.41 1, 2.082.915.
5 W415-0447 / B / 05.24.05 Pur ge all g as lines with the glass door of the fire place open. Assure tha t a continuous g as f low is at the b urner befor e cl o s i ng the door . Under e xtreme v ent configura tions , allow several min utes (5-15) for the flame to stabiliz e after ignition.
6 W415-0447 / B / 05.24.05 Do not use abrasive cleaners to clean plated parts. Buff lightly with a clean dry cloth. The glass is 3/16" ceramic glass available from your Napoleon / Wolf S teel Ltd. dealer . DO NOT SUBSTITUTE MA TERIALS. Clean the glass after the first 10 hours of operation with a recommended gas fireplace glass cleaner .
7 W415-0447 / B / 05.24.05 when (H T ) < (V T ) Simple venting configuration (only one 90° elbow) VERTICAL RISE IN FEET V T FIGURE 4 See graph to determine the required vertical rise V T for the required horizontal run H T .
8 W415-0447 / B / 05.24.05 H 2 H 1 V 1 90° See graph to determine the required verti- cal rise V T for the required horizontal run H T . V 1 = V T = 6 ft H 1 =3 f t H 2 =5 f t H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .03(two 90° elbows - 90°) = .03(180° - 90°) = 2.
9 W415-0447 / B / 05.24.05 REQUIRED VERTICAL RISE IN FEET V T HORIZONT AL VENT RUN PLUS OFFSET IN FEET H T The shaded area within the lines represents acceptable values for H T and V T .
10 W415-0447 / B / 05.24.05 MAXIMUM VERTICAL RISE IN FEET V T HORIZONT AL VENT RUN PLUS OFFSET IN FEET H T The shaded area within the lines represents acceptable values for H T and V T . See graph to determine the required vertical rise V T for the required horizontal run H T .
11 W415-0447 / B / 05.24.05 AIR TERMINAL INST ALLA TIONS * * * * * Recommended to prevent condensation on windows and thermal breakage ** ** ** ** ** It is recommended to use a hea t shield and to maximiz e the distance to vinyl clad soffits. *** *** *** *** *** The periscope GD-201 requir es a minimum 18 inches c lear ance fr om an inside corner .
12 W415-0447 / B / 05.24.05 ROUND OR SQUARE HOLE 12.500" 16.000" c /c 14 7 / 16 " 13" FIGURE 13 This application occurs when venting through an exterior wall. Having determined the air terminal location, cut and frame a hole in an exterior wall.
13 W415-0447 / B / 05.24.05 FIGURE 19 4. Insert the liners through the firestop maintaining the required clearance to combustibles. Secure to the exterior wall and make weather tight by sealing with caulking (not supplied).
14 W415-0447 / B / 05.24.05 FIGURE 23 The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use W olf Steel vent spacers or equivalent every 3 feet and either side of each elbow to maintain the minimum 1¼" clearance between the outer and inner vent pipes.
15 W415-0447 / B / 05.24.05 Pr oceed once the vent installa tion is complete . Note : All gas connections must be contained within the fireplace when complete . 1. The fireplace is de- signed to accept a ½" gas supply line. The fireplace is equipped with a ½" manual shut-off valve, and an 18" listed flexible gas connector .
16 W415-0447 / B / 05.24.05 WARNING Facing and/or finishing material must never o verhang into the fireplace opening. Do not distor t or f o rce the fr ame kit components. W hen using a r ough finish material (i.e.; stone), maintain a ¼” - ½” border from the framing components.
17 W415-0447 / B / 05.24.05 FIGURE 34 MANTLE CLEARANCES Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clearance needed.
18 W415-0447 / B / 05.24.05 Before the glass door can be removed, the control doors must be removed and the hearth strip and screen assembly must be removed. Lift the hearth strip up and away from the front of the fire- place. The curtain assembly can be removed by lifting the rod out from the three hooks at the top inside edge of the door opening.
19 W415-0447 / B / 05.24.05 Glowing embers are NOT recommended. The burner has been designed to achieve maximum glow without embers. 4. Place log #4, with the charred branch pointed inward. Locate the pins into the holes in log#1 and log#2, this will hold the rear log in position.
20 W415-0447 / B / 05.24.05 BLO WER REPLACEMENT The Napoleon MADISON comes equipped with a heat circu- lating blower . The blower is pre-wired and is controlled by the remote control supplied with the unit. For control details, see operation. Pg . 22.
21 W415-0447 / B / 05.24.05 FIGURE 48 1. Unplug the cord from the junction box 2. Pull the the tab on the receiver lock forward. 3. Pull up on the receiver and disconnect the wires. 4. Install the new receiver (see schematic Pg.23) . 1. Remove the hearth strip.
22 W415-0447 / B / 05.24.05 The timer setting is used to maintain the desired room temperature for a specific length of time (1 to 120 minutes) that you want the fireplace to operate. Press the TIMER button once. The LCD will blink "_ _ _". Adjust the time using the up or down arrow keys.
23 W415-0447 / B / 05.24.05 A . This fireplace is equipped with a pilot which must be lit by hand while following these instructions exactly . B. Before operating smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will settle on the floor .
24 W415-0447 / B / 05.24.05 Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports. The flame may not appear yellow immediately; allow 15 to 30 minutes for the final flame colour to be established.
25 W415-0447 / B / 05.24.05 # P ART NO . DESCRIPTION 1 W135-0205 # 1 - REAR LOG 2 W135-0206 # 2 - MIDDLE LOG - NG 3 W135-0207 #3 - RIGHT LOG 4 W135-0208 #4 - LEFT LOG 5 W135-0218 #5 - CROSSOVER LOG 6 .
26 W415-0447 / B / 05.24.05 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf S teel Ltd.
27 W415-0447 / B / 05.24.05 White / grey film forms. Sulphur from fuel is being de- posited on glass, logs or com- bustion chamber surfaces. - clean the glass with a gas fireplace glass cleaner . DO NOT CLEAN GLASS WHEN HOT . If deposits are not cleaned of f regularly , the glass may become per- manently marked.
28 W415-0447 / B / 05.24.05 Remote wall switch is in "OFF" position; main burner comes on when gas knob is turned to "ON" posi- tion. W all switch is mounted up- side down - reverse. Faulty valve. - replace. - replace. Remote wall switch is grounding.
デバイスNapoleon Fireplaces GD80NTの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Napoleon Fireplaces GD80NTをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNapoleon Fireplaces GD80NTの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Napoleon Fireplaces GD80NTの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Napoleon Fireplaces GD80NTで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Napoleon Fireplaces GD80NTを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNapoleon Fireplaces GD80NTの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Napoleon Fireplaces GD80NTに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNapoleon Fireplaces GD80NTデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。