Napoleon FireplacesメーカーGD82NT-Tの使用説明書/サービス説明書
ページ先へ移動 of 31
1 W415-0583 / B / 05.23.07 INST ALLA TION AND OPERA TION INSTRUCTIONS Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.on.ca INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED T O AND REMAIN WITH THE HOMEOWNER.
2 W415-0583 / B / 05.23.07 PG 2-5 INTRODUCTION W arranty Dimensions General Instructions General Information Care of Glass & Plated Parts 5-9 VENTING V ent lengths V enting Specifi cations Air T .
3 W415-0583 / B / 05.23.07 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT T O CHANGE WITHOUT PRIOR NOTICE DUE T O ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. P A TENTS U.S. 5.303.693.801 - CAN. 2.073.41 1, 2.082.
4 W415-0583 / B / 05.23.07 Under extreme vent confi gurations, allow several minutes (5-15) for the fl ame to stabilize after ignition. Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing and operating the fi replace.
5 W415-0583 / B / 05.23.07 24" 16" 8" Do not use abrasive cleaners to clean glass. Buff lightly with a clean dry cloth. The glass is 3/16” ceramic glass available from your Napoleon® / Wolf Steel Ltd. dealer . DO NOT SUB- STITUTE MA TERIALS.
6 W415-0583 / B / 05.23.07 VER TICAL RISE IN FEET V T FIGURE 4 when (H T ) < (V T ) Simple venting confi guration (only one 90° elbow) See graph to determine the required vertical rise V T for the required horizontal run H T .
7 W415-0583 / B / 05.23.07 H 2 H 1 V 1 90° See graph to determine the required verti- cal rise V T for the required horizontal run H T . V 1 = V T = 6 ft H 1 = 3 ft H 2 = 5 ft H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .0 3 (t wo 90° elbows - 90°) = .03(180° - 90°) = 2.
8 W415-0583 / B / 05.23.07 REQUIRED VER TICAL RISE IN FEET V T HORIZONT AL VENT RUN PLUS OFFSET IN FEET H T when (H T ) < (V T ) FIGURE 9 For vent confi gurations requiring more than zero 90° elb.
9 W415-0583 / B / 05.23.07 FIGURE 12.
10 W415-0583 / B / 05.23.07 This application occurs when venting through a roof. Installation kits for various roof pitches are available from your Napoleon® dealer .
11 W415-0583 / B / 05.23.07 1. Move the fi replace into position. 2. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
12 W415-0583 / B / 05.23.07 1. Move the fi replace into position. 2. Fasten the roof support to the roof using the screws pro- vided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
13 W415-0583 / B / 05.23.07 FLUE COLLAR RESTRICTOR PLA TE TOP OF THE FIREBOX Proceed once the vent installation is complete. Note : All gas connections must be contained within the fi replace when complete. 1. The fi replace is designed to accept a ½” gas supply line.
14 W415-0583 / B / 05.23.07 WARNING F acing and/or fi nishing material must ne ver o verhang into the fi replace opening. Do not distor t or force the fr ame kit components. W hen using a rough fi nish materi- al (i.e.; stone), maintain a ¼” - ½” bor der from the fr aming components.
15 W415-0583 / B / 05.23.07 FIGURE 32 MANTLE CLEARANCES 0 34 7 8 9 11 13 12 5 6 7 10 12 H E I G H T M A N T L E MANTLE WIDTH Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clearance needed. Do NOT use the fi replace if any part has been under water .
16 W415-0583 / B / 05.23.07 Optional Front Glass Door Latches Retainer Before the glass door can be removed, the optional front must be removed. The glass door is secured to the top front edge of the fi rebox. Pull the handles of the latches forward, then lift the hooks out from the slots in the door frame to release the top of the door .
17 W415-0583 / B / 05.23.07 FIGURE 39 TOP EDGES BOTTOM EDGES Next, remove the 6 screws that secure the burner base. Once the gas has been disconnected, the burner train assembly will lift out. TOP SIDE OF ROCK CLUSTER 4. After rocks have been placed on the bowl, add the remaining rock by inserting the pin into the hole shown in Fig 40.
18 W415-0583 / B / 05.23.07 BOWL BURNER CURVED DECORA TIVE PA N E L BURNER BOTTOM BURNER BASE S E E - T H R U W I N D O W ELECTRODE BOX (AA Battery Required) CONTROL P ANEL CONTROL P ANEL BA TTER Y REPLACEMENT 1. Remove the optional front. (Instructions on Pg.
19 W415-0583 / B / 05.23.07 Yo u r comes equipped with our Night Light TM . The light has been pre-wired and is controlled from the remote control. If in the event the lamp or lens needs to be replaced, follow the instructions below .
20 W415-0583 / B / 05.23.07 5. F AN SPEED SETTING This function controls the speed of the hot air circulating fan. T o change the fan speed, use the UP and Down button until the cursor (small triangle) is left of the fan icon. Set to one of 4 levels included or turned off (level 4 means full speed) 6.
21 W415-0583 / B / 05.23.07 CHILD SAFETY LOCK-OUT This function is to deactivate con- trol button. The function is active when the lock icon is lit. T o activate this function press the ON / OFF butto.
22 W415-0583 / B / 05.23.07 DIP SWIT CH NUMBER (0 = ON / 1 = OFF) FIGURE 57.
23 W415-0583 / B / 05.23.07 A. This fi replace is equipped with a pilot which must be lit by hand while following these instructions exactly . B. Before operating smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor .
24 W415-0583 / B / 05.23.07 AIR SHUTTER OPENING Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner ports.
25 W415-0583 / B / 05.23.07 CONVERSION KIT This conversion kit shall be installed by a qualifi ed service agency in accordance with the manufacturer ’ s instructions and all applicable codes and requirements of the authority having jurisdiction.
26 W415-0583 / B / 05.23.07 # P ART NO. DESCRIPTION 1 W135-0275 OUTER ROCKS 2 W135-0304 SINGLE ROCK 3 W135-0277 BOWL 4 GL-655 ROCK SET ASSEMBL Y 5 W565-0090 WIRE MESH 6* W390-0002 DOOR LA TCH ( EA ) 7.
27 W415-0583 / B / 05.23.07 35 34 16 48 46 45 22 19 28 18 20 AUX ON 0:00 00 ON/OFF FEATURE SELECT 21 25 23 24 26 1 2 17 4 11 9 13 12 10 54 40 41 42 43 55 39 3 5.
28 W415-0583 / B / 05.23.07 White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a gas fi replace glass cleaner . DO NOT CLEAN GLASS WHEN HOT . If deposits are not cleaned off regularly , the glass may become per- manently marked.
29 W415-0583 / B / 05.23.07 Remote wall switch is in “OFF” position; main burner comes on when gas knob is turned to “ON” position. W all switch is mounted upside down - reverse. Faulty valve. - replace. - replace. Remote wall switch is ground- ing.
30 W415-0583 / B / 05.23.07 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS.
31 W415-0583 / B / 05.23.07 NOTES.
デバイスNapoleon Fireplaces GD82NT-Tの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Napoleon Fireplaces GD82NT-Tをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNapoleon Fireplaces GD82NT-Tの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Napoleon Fireplaces GD82NT-Tの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Napoleon Fireplaces GD82NT-Tで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Napoleon Fireplaces GD82NT-Tを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNapoleon Fireplaces GD82NT-Tの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Napoleon Fireplaces GD82NT-Tに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNapoleon Fireplaces GD82NT-Tデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。