Napoleon FireplacesメーカーGE38NT-Mの使用説明書/サービス説明書
ページ先へ移動 of 28
1 W415-0429 / C / 1 1.04.05 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.
2 W415-0429 / C / 1 1.04.05 WARNING • Do not burn wood or other ma terials in this fi r e place. • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
3 W415-0429 / C / 1 1.04.05 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT T O CHANGE WITHOUT PRIOR NOTICE DUE T O ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. PA TENTS U.S. 5.303.693.801 - CAN. 2.073.41 1, 2.082.
4 W415-0429 / C / 1 1.04.05 THIS GAS FIREPLACE SHOULD BE INST ALLED AND SERV - ICED BY A QUALIFIED INST ALLER to conform with local codes. Installation practices vary from region to region and it is i.
5 W415-0429 / C / 1 1.04.05 Use only Wolf S teel or Simpson Dura-V ent Model DV -GS venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air termi- nal locations for either system are set out in this manual and must be adhered to.
6 W415-0429 / C / 1 1.04.05 AIR TERMINAL INST ALLA TIONS * * * * * Recommended to prevent condensation on windows and thermal breakage * * * * * * * * * * It is recommended t o u s e a h ea t s h i el d a n d t o m a x im i ze t h e d i s ta n c e t o v i ny l cl a d s o f f i ts.
7 W415-0429 / C / 1 1.04.05 Use the GD201 periscope kit to locate the air termination above grade. The periscope must be installed so that when final grading is completed, the bottom air slot is located a minimum of 12 inches above grade. The maximum allow- able vent length depends on the fireplace, as illustrated.
8 W415-0429 / C / 1 1.04.05 for the following symbols used in the venting calcula- tions and examples are: > - greater than > - equal to or greater than < - less than < - equal to or less .
9 W415-0429 / C / 1 1.04.05 H 2 H 1 V 1 90° when (H t ) > (V t ) Simple venting configuration (only one 90° elbow) See graph to determine the required ver- tical rise V T for the required horizontal run H T . V 1 = V T = 6 ft H 1 =3 f t H 2 =5 f t H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .
10 W415-0429 / C / 1 1.04.05 Example 4: V 1 =5 f t V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 =1 f t H 2 =3 f t H 3 = 2.5 ft H R = H 1 + H 2 + H 3 = 1 + 3 + 2.5 = 6.5 ft H O = .03(four 90° elbows - 90°) = .03(90 + 90 + 90 + 90 - 90) = 8.1 ft H T = H R + H O = 6.
11 W415-0429 / C / 1 1.04.05 F or mula 1: H T < 3V T F or mula 2: H T + V T < 40 f eet Example 5: V 1 =2 f t V 2 =1 f t V 3 = 1.5 ft See graph to determine the required vertical rise V T for the required horizontal run H T . For vent configurations requiring elbows, the following for- mulas apply: FIGURE 13 V T = V 1 + V 2 + V 3 = 2 + 1 + 1.
12 W415-0429 / C / 1 1.04.05 FIGURE 15 This application oc- curs when venting through a roof. Installa- tion kits for various roof pitches are available from your Napoleon dealer .
13 W415-0429 / C / 1 1.04.05 Use only approved aluminum flexi- ble liner kits marked: "W olf Steel Appr oved V enting" as identif ied by the stamp only on the 7” outer liner . 1. Cut or frame a hole in an exterior wall with a minimum round or square opening listed on page 5.
14 W415-0429 / C / 1 1.04.05 FIGURE 25 The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use W olf S teel vent spacers every 3 feet and either side of each elbow to maintain the minimum 1¼" clearance between the outer and inner vent pipes.
15 W415-0429 / C / 1 1.04.05 Proceed once the vent installation is complete. 1. Move the fireplace into position and secure using the nailing tabs and/or secure to the floor through the ¼"diam- eter holes located at either end of the base. 2. Route a 3/8" N.
16 W415-0429 / C / 1 1.04.05 37 3 / 4 " 6 " 1 7 3 / 4 " INSIDE CHASE 37 3 / 4 " 40 1 / 8 " 56 3 / 4 " 37 3 / 4 " 39 1 / 4 " 17 3 / 4 " 7 " 4 " It is not necessary to install a hearth extension with this fireplace system.
17 W415-0429 / C / 1 1.04.05 Lift up and remove the upper louvres. Open the valve control door . Release the top and bot- tom door latches, located at the right side of the door . T o close the door, repeat in re- verse order . The door latch holes are elongated for door levelling.
18 W415-0429 / C / 11.04.05 4. Place the bottom of log #6 against the right side of the firebox. The upper branch rests against log #1 . The lower branch rests against the 4th and 5th grate posts. Remove the backing of the logo supplied and place on the glass viewing door, as indicated.
19 W415-0429 / C / 1 1.04.05 FIGURE 46 7. Remove the flame effect panel by removing the 6 screws. 8. Remove the flame generator by sliding to the left and dislodging the neoprene tube from the motor shaft. Next, slide the flame generator to the right to remove the shaft from the nylon bearing.
20 W415-0429 / C / 1 1.04.05 1. Turns electric flame on/off. 2. Turns gas flame on/off. 3. Activates gas flame adjustment. 4. Activates fan adjustment. 5. Adjusts options #3 & #4 up. 6. Sets the timer . 7. Adjusts options #3 & #4 down. 8. Sets the time.
21 W415-0429 / C / 1 1.04.05 • Turn off all gas to the fireplace. • Open windows. • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour's phone.
22 W415-0429 / C / 1 1.04.05 This fireplace requires 6 amps, 120 volt and a 60 hz grounded circuit. Do NOT use the fireplace if any part has been under water . Call a qualified service tec hnician IMMEDIA TEL Y to have the fireplace inspected for damage to the electrical cir- cuit.
23 W415-0429 / B / 05.25.04 Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow . Air shutters have been factory set open according to the chart below: These settings are for the maximum horizontal vent run.
24 W415-0429 / C / 11.04.05 GD 2 20 (5 FT) # P AR T NO . DESCRIPTION 37* W010-0397 4" FLEXIBLE ALUMINIUM LINER - (5 FT ) C / W SP ACERS 37* W410-0017 7" FLEXIBLE ALUMINIUM LINER - (5 FT ) GD330 (10 FT) # P AR T NO .
25 W415-0429 / C / 1 1.04.05 48 45 44 46 47 12 13 * 16 14 11 55 22 21 39 66 50 51 60 59 ATTENTION-CHAUD C A U T I O N - H O T 40 2 A U T O O N / O F F M A N U A L O N / O F F F l a m e F a n Tim e r C l o c k 24 27 28 26 7 3 4 5 1 6 23 20 29 17 25 33 30 31 32 34 35 36 * W ARNING: This is a fast acting thermocouple.
26 W415-0429 / C / 1 1.04.05 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor . - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed.
27 W415-0429 / C / 1 1.04.05 Remote control - Dead batteries. - Make sure batteries are charged. not working - No power to the unit. - Make sure main power is on. - Power turned off. - Turn on manual power switch. - Power button on control - Make sure the power button is on REMOTE setting.
28 W415-0429 / C / 11.04.05 Excessive noise - Flame generator motor is - Consult your local dealer. coming from the unit. faulty. Odour - Initial curing process. - Run the main burner until odour ceases. - Dust has settled in the - Consult your local dealer.
デバイスNapoleon Fireplaces GE38NT-Mの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Napoleon Fireplaces GE38NT-Mをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNapoleon Fireplaces GE38NT-Mの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Napoleon Fireplaces GE38NT-Mの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Napoleon Fireplaces GE38NT-Mで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Napoleon Fireplaces GE38NT-Mを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNapoleon Fireplaces GE38NT-Mの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Napoleon Fireplaces GE38NT-Mに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNapoleon Fireplaces GE38NT-Mデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。