Napoleon FireplacesメーカーGT8Pの使用説明書/サービス説明書
ページ先へ移動 of 22
1 W415-0619 / B / 03.03.08 INST ALLA TION AND OPERA TION INSTRUC TIONS W olf Steel Ltd., 24 Napoleon Rd ., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 ww w .napoleonreplaces .com • ask@napoleon.on.ca CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL ST ANDARDS: CSA 2.
2 W415-0619 / B / 03.03.08 PG 2-5 INTRODUCTION W arranty General Instructions General Information Care of Glass and Plated Parts Dimensions 5-10 VENTING V enting Lengths and Air T erminal Locations Ve.
3 W415-0619 / B / 03.03.08 ® ® ® ® ® ® ® ® ® ® ® ®® ® ® ® ® e following ma te rials and workmanship in your new NAPO LEON® gas firepla ce are waanted agains t defects for as long as you own the fireplace.
4 W415-0619 / B / 03.03.08 THIS GAS FIREPLACE SHOULD BE INST ALLED AND SERVICED BY A QUALIFIED INST ALLER to conform with local codes. Installation practices vary from region to region and it is impor.
5 W415-0619 / B / 03.03.08 3 / 4 43 GAS LINE ACCESS ELECTRICAL ACCESS FIGURES 1a-c The glass is 3/16” ceramic glass, available from your Napoleon® / Wolf Steel Ltd. dealer . Clean the glass after the fi rst 10 hours of operation with a recommended gas fi replace glass cleaner .
6 W415-0619 / B / 03.03.08 For safe and proper operation of the fi replace follow the venting instruction exactly . Deviation from the minimum or the maximum vertical vent length can create dif fi culty in burner start-up and/or carboning.
7 W415-0619 / B / 03.03.08 TYPICAL VENT INST ALLA TIONS - HORIZONT AL TERMINA TION MIN MAX FIGURE Allowable 3” vent connections (excluding fi replace and air terminal connections) N/A 1 Rise per fo.
8 W415-0619 / B / 03.03.08 TYPICAL VENT INST ALLA TIONS - VERTICAL TERMINA TION 24” MIN. MINIMUM VERITICAL 4” MIN. FIGURE 3a 24” MIN. MINIMUM VERITICAL MAXIMUM HORIZONT AL 5 FT MAX.
9 W415-0619 / B / 03.03.08 O O B B G A F C H H L K J M MINIMUM AIR TERNMINAL L OCA TION CLEARANCES N D E O FIGURE 4.
10 W415-0619 / B / 03.03.08 INST ALLA TION / FRAMING WALL AND CEILING PRO TECTION This application occurs when venting through an exterior wall. Having determined the air terminal location, cut and frame a hole in an exterior wall with a minimum square opening of 8” wide x 8” high.
11 W415-0619 / B / 03.03.08 1. Stretch the 3” fl exible vent pipe to the required length taking into account the additional length needed for the fi nished wall surface.
12 W415-0619 / B / 03.03.08 HIGH TEMPERA TURE SEALANT 1 1 / 2 ” OVERLAP SCREWS 1. Install the 3” fl exible vent pipe to the fi replace. Secure with 3 screws and fl at washers. Seal the joint and screw holes using Mill Pac sealant (W573-0007 not supplied).
13 W415-0619 / B / 03.03.08 Do NOT use the fireplace if any part has been under water . Call a qualified service technician IMMEDIA TEL Y to have the fi replace inspected for damage to the electrical circuit. IT IS NECESSAR Y T O HARD WIRE THIS FIREPLACE.
14 W415-0619 / B / 03.03.08 FRAMING FIGURES 21a,b&c NAILING T AB INST ALLA TION Attach the 4 nailing tabs supplied to the sides of the outer shell as illustrated using the 8 self-tapping screws included in the manual baggie. FIGURE 20 The has been designed to be installed mid-way up a wall.
15 W415-0619 / B / 03.03.08 2” MIN.* 12” MIN. TO COMBUSTIBLES (to ceiling or mantle) 1 1 / 2 ” MIN. * Any protruding finishing material installed in this space (ie. baseboards) must leave 2” of unobstructed clearance to allow for full rotation of the control door .
16 W415-0619 / B / 03.03.08 FIGURE 28 RECEIVING SLOTS DOOR STOP CHAIN FRAME/FRONT INST ALLA TION 1. Align the two holes in the upper portion of the hinge on the control door to those in the bottom trim bracket, secure using two of the #8 x 1/2” hex head screws supplied.
17 W415-0619 / B / 03.03.08 LK8 LIGHT INST ALLA TION (OPTIONAL) 1 . T urn off the electrical and gas supply to the fi replace. 2 . Remove the frame from the unit by removing the 2 black securing screws from the top, and the 2 silver hex head securing screws from the bottom.
18 W415-0619 / B / 03.03.08 A. This fi replace is equipped with an ignition device which automatically lights the burner . Do not try to light by hand. B. Before operating, smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor .
19 W415-0619 / B / 03.03.08 Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner ports. The fl ame may not appear yellow immediately; allow 15 to 30 minutes for the fi nal fl ame color to be established.
20 W415-0619 / B / 03.03.08 # P ART NO. DESCRIPTION 1 W225-0216 DOOR FRAME 2* W562-0008 DOOR GASKET 3* W010-1736 DOOR LA TCH ASSEMBL Y 4 W010-1743 GLASS C / W GASKET 5* W300-0088 GLASS 6 W100-0104 BUR.
21 W415-0619 / B / 03.03.08 TR OUBLE SHOO TING GUIDE BEFORE A TTEMPTING TO TROUBLESHOOT , PURGE YOUR UNIT AND INITIALL Y LIGHT THE IGNITOR AND THE MAIN BURNER WITH THE GLASS DOOR OPEN . SYMPTOM PROBLEM TEST SOLUTION Electrode sparks, burner ignites, electrode continues to spark for complete 7 seconds, burner shuts down.
22 W415-0619 / B / 03.03.08 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS.
デバイスNapoleon Fireplaces GT8Pの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Napoleon Fireplaces GT8Pをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNapoleon Fireplaces GT8Pの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Napoleon Fireplaces GT8Pの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Napoleon Fireplaces GT8Pで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Napoleon Fireplaces GT8Pを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNapoleon Fireplaces GT8Pの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Napoleon Fireplaces GT8Pに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNapoleon Fireplaces GT8Pデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。