NapoleonメーカーGDI-44Nの使用説明書/サービス説明書
ページ先へ移動 of 16
1 W415-0314 / C / 01.15.04 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.
2 W415-0314 / C / 01.15.04 WARNING • The fireplace insert is a vented gas-fired heater . Do not burn wood or other materials in this fireplace insert. • Adults and especially children should be alerted to the hazards of high surface temperatures and should sta y away to avoid burns or clothing ignition.
3 W415-0314 / C / 01.15.04 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001:2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0314 / C / 01.15.04 FOR YOUR SA TISF ACTION, THIS FIREPLACE INSERT HAS BEEN TEST -FIRED TO ASSURE ITS OPERA TION AND QUALITY! Minimum inlet gas supply pressure is 4.
5 W415-0314 / C / 01.15.04 Pro vide adequate v entilation air . Provide adequate accessibility clearance for ser vicing and operating the fir eplace inser t. Never obstruct the front opening of the fire- place inser t. Objects placed in front of the fireplace must be kept a minimum of 48" away from the front face of the unit.
6 W415-0314 / C / 01.15.04 2. Gently stretch the liners to the required lengths and in- sert into the chimney . Place the terminal onto the top of the chimney cap and fit the flashing plate to suit. Make weather tight by sealing with caulking (not supplied) and fasten to the chimney with screws and plugs (not supplied).
7 W415-0314 / C / 01.15.04 For ease of accessibility , an optional remote wall switch or millivolt thermostat may be installed in a convenient location. Route 2-strand solid core millivolt wire from the gas fireplace insert to the wall switch / millivolt ther- mostat.
8 W415-0314 / C / 01.15.04 Place the door into the two lower door brackets and secure at the top of the unit with two #10-24 screws. FIGURE 16 MANTLE W IDTH H E I G H T M A N T L E PHAZER TM logs, exclusive to Napoleon Fireplaces, pro- vide a unique and realistic glowing effect that is different in every installation.
9 W415-0314 / C / 01.15.04 Purge all gas lines with the glass door open. Assure that a continuous gas flow is at the burner before clos- ing the door . Allow sever al minutes (5-15) for the flame to stabilize after ignition. Do not operate the main burner of the in- sert with the door removed.
10 W415-0314 / C / 01.15.04 1. Turn off the electrical power and the gas supply to the fireplace insert. 2. Remove the fire viewing door . Remove the logs, log support and backwall. 3. Remove the blower access door held on with 10 screws. Replace the blower access door gasket when changing the blower .
11 W415-0314 / C / 01.15.04 Remove the pilot screw cap. Adjust the pilot screw to pro- vide properly sized flame. Turn in a clockwise direction to reduce the gas flow .
12 W415-0314 / C / 01.15.04 # P A R T # DESCRIPTION 1 W725-0039 RBT SH AW V ALVE - NG 1 W725-0040 RBT SH AW V ALVE - L P 2 W100-0075 BURNER TUBE 3 W010-0893 BURNER P AN 4* W455-0065 #45 FRONT BURNER O.
13 W415-0314 / C / 01.15.04 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
14 W415-0314 / C / 01.15.04 Main burner goes out; pilot stays on. Pilot flame is not large enough or not engulfing the thermopile. Thermopile shorting Remote wall switch wire is too long, too much resistance in the system Faulty thermostat or switch - turn up pilot flame.
15 W415-0314 / C / 01.15.04 Exhaust fumes smelled in room, headaches. - check all seals. Fireplace is spilling. Carbon is being de- posited on glass, logs or combustion chamber surfaces. Flame is impinging on the logs or combustion chamber . - check that the logs are correctly positioned.
16 W415-0314 / C / 01.15.04 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Deale.
デバイスNapoleon GDI-44Nの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Napoleon GDI-44Nをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNapoleon GDI-44Nの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Napoleon GDI-44Nの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Napoleon GDI-44Nで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Napoleon GDI-44Nを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNapoleon GDI-44Nの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Napoleon GDI-44Nに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNapoleon GDI-44Nデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。