National InstrumentsメーカーNI 785xRの使用説明書/サービス説明書
ページ先へ移動 of 74
Intelligent DAQ NI R Series Intellig ent DAQ User Manual NI 781xR, 783xR, NI 784xR, and NI 785xR D evices R Series Intelligent DAQ User Manual June 2008 370489F-01.
Support Worldwide Technical Support and Product Info rmation ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Aust in, Texas 78759-3504 USA Tel: 512 683 0100 Worldwide O.
Important Information Warranty The NI 7811R/ 7813R/7830R/ 7831R/7833R/ 7841R/7842 R/7851R/78 52R/7853R/78 54R is warrant ed against defects i n materials and workmanshi p for a period of on e year from the da te of shipment, as evidenced by receip ts or other do cumentation.
Compliance Compliance with FCC/Canada Radio Frequency Interference Regulations Determining FCC Class The Federal Communications Commission (FCC) has rules to protect wireless co mmunications from inte rference. The FCC places digital electronics into two classes.
© National Instruments Corporation v R Series Intelligent DAQ User Manual Contents About This Manual Conventions ............ .............. .............. .............. ........... ............... .............. .............. ....... v ii Related Documentation .
Contents R Series Intelligent DAQ User Manual vi ni.com Types of Signal Sources ........ .............. ............ .............. .............. .............. .............. ...... 2-8 Floating Signal Sources ... .............. .............. .....
© National Instruments Co rporation vii R Series Inte lligent DAQ User Manual About This Manual This manual describes the electrical and mechanical aspects of the National Instruments 781 x R/ 783 x R/784 x R/785 x R devices and contains information about programming and using the devices.
About This Manual R Series Intelligent DAQ User Manual viii ni.com monospace T ext in this font denotes text or ch aracters that you should ent er from the keyboard, sections of code, programming examples, and syntax examples.
About This Manual © National Instruments Corporation ix R Series Intelligent DAQ User Manual information about using the FPGA Module to create VIs that run on the NI 78 xx R device.
About This Manual R Series Intelligent DAQ User Manual x ni.com Additional Resources The following documents contain information you migh t find helpful: • NI Dev eloper Zone tutorial, Field Wiring and Noise Considerati ons for Analog Signals , at ni.
© National Instruments Corporation 1-1 R Series Intelligent DAQ User Manual 1 Introduction This chapter describes the NI 781 x R/783 x R/784 x R/785 x R, the concept of the Reconfigurable I/O (RIO) device, optional software and equipment for using the NI 78 xx R, and safety information about the NI 78 xx R.
Chapter 1 Introduction R Series Intelligent DAQ User Manual 1-2 ni.com instrument (VI) to the FPGA. Using the FPGA Module, you can graphically design the timing an d functionality of the R Series device.
Chapter 1 Introduction © National Instruments Corporation 1-3 R Series Intelligent DAQ User Manual PXI-specific features are implemen ted on the J2 connector of the CompactPCI b us. T able 1-2 lists th e J2 pins used by the NI PXI-78 xx R. The NI 78 xx R is compatible with any CompactPCI chassis with a sub-bus that does not driv e these lines.
Chapter 1 Introduction R Series Intelligent DAQ User Manual 1-4 ni.com Flexible Functionality Flexible function ality allows the N I 78 xx R to match indi vidual application requirements and t o mimic th e functionality of fixed I/ O devices.
Chapter 1 Introduction © National Instruments Corporation 1-5 R Series Intelligent DAQ User Manual Reconfigurable I/O Architecture Figure 1-1 shows an FPGA connected to fixed I/O resources and a bus interface. The fix ed I/O resources include A/D con verters (ADCs), D/A con verters (D A Cs), and digital I/O lines.
Chapter 1 Introduction R Series Intelligent DAQ User Manual 1-6 ni.com The FPGA does not retain the VI when the R Series de vice is po wered off, so you must reload the VI each time you po wer on the de vice. Y ou can load the VI from onboard flash memory or from software o ver the b us interf ace.
Chapter 1 Introduction © National Instruments Corporation 1-7 R Series Intelligent DAQ User Manual Note If you use the R Series device without the FPGA Module, you can use the RIO Device Setup utilit.
Chapter 1 Introduction R Series Intelligent DAQ User Manual 1-8 ni.com Cables and Accessories National Instruments offers a v ariety of product s you can use with R Series devices, including cables, connect or blocks, and other accessories, as shown in Table 1-3.
Chapter 1 Introduction © National Instruments Corporation 1-9 R Series Intelligent DAQ User Manual Custom Cabling NI offers a variety of cables for connecting signals to the N I 78 xx R. If you need to develop a custom cable, a nont erminated shiel ded cable is available from NI.
Chapter 1 Introduction R Series Intelligent DAQ User Manual 1-10 ni.com • Pollution Degree 3 means that conductiv e pollution occurs, or dry , nonconductiv e pollution occurs that becomes conductive due to condensation. Y ou must insulat e signal connectio ns for the m aximum voltage for w hich the device is rated.
Chapter 1 Introduction © National Instruments Corporation 1-11 R Series Intelligent DAQ User Manual • Measurement Category III is for measurements performed in the building installation at the distribution le vel.
© National Instruments Corporation 2-1 R Series Intelligent DAQ User Manual 2 Hardware Over view of the NI 78 xx R This chapter presents an overview of the hardware functi ons and I/O connectors on the NI 78 xx R. Figure 2-1 shows a block diagram for the NI 781 x R.
Chapter 2 Hardware Overv iew of the NI 78x x R R Series Intelligent DAQ User Manual 2-2 ni.com Figure 2-2. NI 7830R Block Diagram RTSI/PXI Triggers PXI Local Bus (NI PXI-7830R only) Connector 0 (MIO) .
Chapter 2 Hardware O verview of the NI 78x x R © National Instruments Corporation 2-3 R Series Intelligent DAQ User Manual Figure 2-3. NI 783 1R/7833R/784 x R/785 x R Block Diagram NI 7811R Over view The NI 7811R has 1 60 bidirectional DIO lines and a V irtex-II XC2V100 0 FPGA.
Chapter 2 Hardware Overv iew of the NI 78x x R R Series Intelligent DAQ User Manual 2-4 ni.com NI 7831R/7833R Over view The NI 7831R/7833R each have eight independent, 16-bit AI channels; eight independent, 16-bi t AO channels; 96 bidirecti onal DIO lines that you can configure individually for input or ou tput; and a V irtex-II XC2V3000 FPGA.
Chapter 2 Hardware O verview of the NI 78x x R © National Instruments Corporation 2-5 R Series Intelligent DAQ User Manual Input Modes The NI 783 x R/784 x R/785 x R input mode is software configurab le. The input channels support three input mo des—differential (D IFF), referenced single ended (RSE), and nonreferenced single ended (NRSE).
Chapter 2 Hardware Overv iew of the NI 78x x R R Series Intelligent DAQ User Manual 2-6 ni.com Connecting Analog Input Signals The AI signals for the NI 783 x R/78 4 x R/785 x R are AI<0.. n >+, AI<0.. n >– , AIGND, and AISENSE. For the NI 7830R, n =4.
Chapter 2 Hardware O verview of the NI 78x x R © National Instruments Corporation 2-7 R Series Intelligent DAQ User Manual Connection of AI signals to the NI 783 x R/784 x R/78 5 x R depends on the input mode of the AI channels you are using and the typ e of input signal source.
Chapter 2 Hardware Overv iew of the NI 78x x R R Series Intelligent DAQ User Manual 2-8 ni.com T ypes of Signal Sources When configuring t he input channels and making signal connections, you must first det ermine whether the signal sources are fl oating or ground referenced.
Chapter 2 Hardware O verview of the NI 78x x R © National Instruments Corporation 2-9 R Series Intelligent DAQ User Manual Figure 2-5 summarizes the recommended in put mode for both types of signal sources.
Chapter 2 Hardware Overv iew of the NI 78x x R R Series Intelligent DAQ User Manual 2-10 ni.com Differential Connection Consid erations (DIFF Input Mode) In DIFF input mode, the NI 783 x R/784 x R/785 x R measures the difference between the positive and negative input s.
Chapter 2 Hardware O verview of the NI 78x x R © National Instruments Corporation 2-11 R Series Intelligent DAQ User Manual Differential Connections for Ground-Referenced Signal Sources Figure 2-6 shows how to co nnect a gr ound-referenced signal source to a channel on the NI 783 x R/784 x R/785 x R configur ed in DIFF input mode.
Chapter 2 Hardware Overv iew of the NI 78x x R R Series Intelligent DAQ User Manual 2-12 ni.com Differential Connections for Nonreferenced or Floating Signal Sources Figure 2-7 shows how to connect a floa ting signal source to a channel on the NI 783 x R/784 x R/785 x R configured in DI FF input mode.
Chapter 2 Hardware O verview of the NI 78x x R © National Instruments Corporation 2-13 R Series Intelligent DAQ User Manual line to AIGND, connect it to AIGND th rough a resistor that is about 100 times the equiv alent source impeda nce. The resistor puts the signal path nearly in balance.
Chapter 2 Hardware Overv iew of the NI 78x x R R Series Intelligent DAQ User Manual 2-14 ni.com Use DIFF input connections for greater signal integrity for any input signal that does not meet the preceding conditions. Y ou can configure the NI 783 x R/784 x R/785 x R channels in softw are for RSE or NRSE input modes.
Chapter 2 Hardware O verview of the NI 78x x R © National Instruments Corporation 2-15 R Series Intelligent DAQ User Manual Single-Ended Connections for Grounded Signal Sources (NRSE Input Mode) To measure a grounded signal source with a single-ended input mode, you must configure the NI 783 x R/784 x R/785 x R in the NRSE input mode.
Chapter 2 Hardware Overv iew of the NI 78x x R R Series Intelligent DAQ User Manual 2-16 ni.com Common-Mode Signal Re jection Considerations Figure 2-6 and Figure 2-9 show connectio ns for signal sources that are already referenced to some ground point with respect to the NI 783 x R/784 x R/785 x R.
Chapter 2 Hardware O verview of the NI 78x x R © National Instruments Corporation 2-17 R Series Intelligent DAQ User Manual Connecting Analog Output Signals The AO signals are AO <0.. n > and AOGND. AO < 0 . . n > are the A O channels. A O GND is the ground reference signal for the A O channels.
Chapter 2 Hardware Overv iew of the NI 78x x R R Series Intelligent DAQ User Manual 2-18 ni.com NI 7830R has one RMIO and one RDIO connector for a total of 56 DIO lines. The NI 7831R/7833R/78 4 x R/785 x R has one RMIO and two RDIO connectors for a total of 96 DIO lines.
Chapter 2 Hardware O verview of the NI 78x x R © National Instruments Corporation 2-19 R Series Intelligent DAQ User Manual Figure 2-11. Example Digital I/O Connections Figure 2-11 shows DIO<0..3> configured for digital input and DIO<4..7> configured for digital ou tput.
Chapter 2 Hardware Overv iew of the NI 78x x R R Series Intelligent DAQ User Manual 2-20 ni.com The SHC68-68-RDIO was designed specifically for R Series de vices and is the NI-recommended cable for digital applications. If you are using the SH68-C68-S cable, howe ver , p lease no te the following considerations.
Chapter 2 Hardware O verview of the NI 78x x R © National Instruments Corporation 2-21 R Series Intelligent DAQ User Manual R TSI T rigger Bus The NI 78 xx R can send and receive triggers through the RTSI trigger bus. The RTSI bus provides ei ght shared trigger lines that connect to all the devices on the bus.
Chapter 2 Hardware Overv iew of the NI 78x x R R Series Intelligent DAQ User Manual 2-22 ni.com The PXI local bus right lines on the NI PXI-781 x R/783 x R are PXI/LBR<0..12> . The PXI l ocal bus left lines on the NI PXI-781 x R /783 x R are PXI/LBLSTAR<0.
Chapter 2 Hardware O verview of the NI 78x x R © National Instruments Corporation 2-23 R Series Intelligent DAQ User Manual Figure 2-12. PXI Star T rigger Connections in a PXI Chassis Refer to the PXI Hardware Specifica tion Revision 2.1 and PXI Sof tware Specification Revision 2.
Chapter 2 Hardware Overv iew of the NI 78x x R R Series Intelligent DAQ User Manual 2-24 ni.com Figure 2-13. Switch Location on the NI PCI-781 x R SW1, SW2, SW3.
Chapter 2 Hardware O verview of the NI 78x x R © National Instruments Corporation 2-25 R Series Intelligent DAQ User Manual Figure 2-14. Switch Location on the NI PXI-781 x R NI P XI- 7811 R Reconfig.
Chapter 2 Hardware Overv iew of the NI 78x x R R Series Intelligent DAQ User Manual 2-26 ni.com Figure 2-15. Switch Location on the NI PCI-783 x R SW1, SW2, SW3.
Chapter 2 Hardware O verview of the NI 78x x R © National Instruments Corporation 2-27 R Series Intelligent DAQ User Manual Figure 2-16. Switch Location on the NI PXI-783 x R Figure 2-17. Switch Settings Complete the following steps to pr e vent a VI stored in flash memory from loading to the FPGA: 1.
Chapter 2 Hardware Overv iew of the NI 78x x R R Series Intelligent DAQ User Manual 2-28 ni.com 3. Move SW1 to the ON position, as shown in Figure 2-17b.
Chapter 2 Hardware O verview of the NI 78x x R © National Instruments Corporation 2-29 R Series Intelligent DAQ User Manual (NI 784 x R/785 x R Devices) All NI 784 x R/78 5 x R devices ha v e a user-replac eable socketed fuse to protect the supply from ov ercurrent conditions.
Chapter 2 Hardware Overv iew of the NI 78x x R R Series Intelligent DAQ User Manual 2-30 ni.com 3. Replace the broken fuse while ref erring to Figure 2-18 fo r the fuse locations. Figure 2-18. NI 784 x R/785 x R Replacement Fuse Location 4. Reinstall the PCI or PXI de vice into the computer or PXI chassis.
Chapter 2 Hardware O verview of the NI 78x x R © National Instruments Corporation 2-31 R Series Intelligent DAQ User Manual Field Wiring Considerations (NI 783 x R/784 x R/785 x RO n l y ) Environmen.
© National Instruments Corporation 3-1 R Series Intelligent DAQ User Manual 3 Calibration (NI 783 x R/784 x R/785 x RO n l y ) Calibration is the process of determin ing and/or adjusting the accuracy of an instrument to m inimize measurement and output voltage errors.
Chapter 3 Calibration ( N I 783x R/784x R/785x R Only) R Series Intelligent DAQ User Manual 3-2 ni.com application. Internal calibration mini mizes the effects of any offset and gain drifts, partic ularly those due t o changes in temperature.
Chapter 3 Calibration (NI 7 83x R/784x R/785x R Only) © National Instruments Corporation 3-3 R Series Intelligent DAQ User Manual T o externally calibrate your de vice, use an e xternal reference se veral times more accurate than the de vice itself.
© National Instruments Corporation A-1 R Series Intelligent DAQ User Manual A Connecting I/O Signals This appendix describes how to make input and output signal connections to the NI 78 xx R I/O connectors. Figure A-1 sho ws the I/O connector pin assignments and locations for NI PCI-7811R/7813R and NI PXI-7811R/7813R.
Appendix A Connecting I/O Signals R Series Intelligent DAQ User Manual A-2 ni.com Figure A-1. NI 781 x R Connector Pin Assignments and Locations DGND DGND DGND DGND DGND DGND DGND DGND DGND DGND DGND .
Appendix A Connecting I/O Signals © National Instruments Corporation A-3 R Series Intelligent DAQ User Manual Figure A-2. NI 783 x R/784 x R/785 x R Connector Pin Assignments and Locations +5V DGND D.
Appendix A Connecting I/O Signals R Series Intelligent DAQ User Manual A-4 ni.com T o access the signals on the I/O connect ors, you must connect a cable from the I/O connector to a signal acces sory .
Appendix A Connecting I/O Signals © National Instruments Corporation A-5 R Series Intelligent DAQ User Manual Caution Connections that exceed any of the maximum ratings of input or output si gnals on the NI 78 xx R can damage the NI 78 xx R and the computer .
Appendix A Connecting I/O Signals R Series Intelligent DAQ User Manual A-6 ni.com Connecting to 5B and SSR Analog Signal Conditioning (NI 783 x R/784 x R/785 x R Only) NI provides cables that allo w y.
Appendix A Connecting I/O Signals © National Instruments Corporation A-7 R Series Intelligent DAQ User Manual Figure A-3 shows the connector pinouts when us ing the NSC68-262650 cable.
Appendix A Connecting I/O Signals R Series Intelligent DAQ User Manual A-8 ni.com Y ou can plug each of these 50-pin head ers directly into an 8-, 16-, 24-, or 32-channel SSR backplane for dig ital signal conditioning. One of th e 50-pin headers contains DIO<0.
© National Instruments Corporation B-1 R Series Intelligent DAQ User Manual B Using the SCB-68 Shielded Connector Block This appendix describes how to connect input and output signals to the NI 78 xx R with the SCB-68 shielded connector block. The SCB-68 has 68 screw terminals for I/O signal connections.
© National Instruments Corporation C-1 R Series Intelligent DAQ User Manual C T echnical Support and Professional Ser vices Visit the following sections of the award-winning National Instruments Web site at ni.com for technical support and professional services: • Support —T echnical support resources at ni.
Appendix C T echnical Support and Professional Services R Series Intelligent DAQ User Manual C-2 ni.com • Declaration of Conformit y (DoC) —A DoC is our claim of compliance with the C ouncil of th e European Communities using the manufacturer’ s declaration of conformity .
© National Instruments Corporation G-1 R Series Intelligent DAQ User Manual Glossar y Symbol Pref ix V alu e pp i c o 1 0 –1 2 nn a n o 1 0 –9 µ micro 10 –6 m milli 10 –3 k kilo 10 3 Mm e g a 1 0 6 Gg i g a 1 0 9 Numbers/Symbols ° Degrees. > Greater than.
Glossary R Series Intelligent DAQ User Manual G-2 © National Instruments Corporation Square root of. +5V +5 VDC source signal. A A Amperes. A/D Analog-to-digital . A C Alternating curren t. ADC Analog-to-digital con verter—An elect ronic de vice, often an integrated circuit, that con verts an an alog voltage to a digital number .
Glossary © National Instruments Corporation G-3 R Series Intelligent DAQ User Manual C CC e l s i u s . CalD A C Calibration D A C. CH Channel—Pin or wire lead to wh ich you apply or from which you read the analog or digital signal. Anal og signals can be single-ended or differential.
Glossary R Series Intelligent DAQ User Manual G-4 © National Instruments Corporation DIO Digital input /output. DIO< i > Digital input/ou tput channel signal. DMA Direct memory access—A method by which data can be transferred to/from computer memory from/to a device or memory on the bus while the processor does something else.
Glossary © National Instruments Corporation G-5 R Series Intelligent DAQ User Manual I I/O Input/output—The transfer of data to/from a computer sy stem in volving communications channels, operator interface de vices, and/or data acquisition and control interfaces.
Glossary R Series Intelligent DAQ User Manual G-6 © National Instruments Corporation N noise An undes irable electrical signal—Nois e comes from external sources such as the A C power line, motors,.
Glossary © National Instruments Corporation G-7 R Series Intelligent DAQ User Manual R RAM Random-access memory—The generic term for the read/write memory that is used in computers. RAM allows bits and bytes to be written to it as well as read from.
Glossary R Series Intelligent DAQ User Manual G-8 © National Instruments Corporation T THD T otal harmonic distortion—The rati o of the total rms signal due to harmonic distortion to the overall rms signal, in decibel or a percentage. thermocouple A temperature se nsor created by joining tw o dissim ilar metals.
デバイスNational Instruments NI 785xRの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
National Instruments NI 785xRをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNational Instruments NI 785xRの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。National Instruments NI 785xRの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。National Instruments NI 785xRで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
National Instruments NI 785xRを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNational Instruments NI 785xRの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、National Instruments NI 785xRに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNational Instruments NI 785xRデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。