National InstrumentsメーカーPXI NI PXI-8105の使用説明書/サービス説明書
ページ先へ移動 of 73
PXI NI PXI-8105 User Manual NI PXI-8105 User Manual April 2006 371755B-01.
Support Worldwide Technical Support and Product Info rmation ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Aust in, Texas 78759-3504 USA Tel: 512 683 0100 Worldwide O.
Important Information Warranty The NI PXI-8105 em bedded controller is warranted against defects in materials and workm anship for a period of one year from the date of shipment, as evidenc ed by receipts or othe r documentation.
Compliance Compliance with FCC/Canada Radio Frequency Interference Regulations Determining FCC Class The Federal Communications Commission (FCC) has rules to protect wireless co mmunications from inte rference. The FCC places digital electronics into two classes.
© National Instruments Corpor ation v NI PXI-8105 User Manual Contents About This Manual How to Use the Documentation Se t ............. .............. ........... .............. .............. ............. vii Conventions ............ .............
Contents NI PXI-8105 User Manual vi ni.com Chapter 3 I/O Information Front Panel Connectors ............... .............. .............. .............. .............. .............. ............ 3-1 Front Panel............... .............. .........
© National Instruments Corporat ion vii NI PXI-8105 User Manual About This Manual This manual contains detailed instructions for instal ling and configuring your National Instruments NI PXI-8105 embed ded controller kit.
About This Manual NI PXI-8105 User Manual viii ni.com monospace bold Bold text in this font denotes the messages and responses that the com puter automatically print s to the screen. Th is font also emphasizes lines o f code that are dif ferent from the other examples.
© National Instruments Corporat ion 1-1 NI PXI-8105 User Manual 1 Introduction Benefits of PXI The PXI (PCI eXtensions for Inst rument ation) industry standard, an open specification governed by the PXI Sy stems Alliance (PXISA), defines a compact modular PC platform for test, measurement, and control systems.
Chapter 1 Introduction NI PXI-8105 User Manual 1-2 ni.com NI PXI-8105 Description The NI PXI-8105 PXI/CompactPCI embedded computer is a high-performance PXI/CompactPCI system controll er. The NI PXI-8105 controller integrates st andard I/O features in a single unit by using state-of-the-art packaging.
Chapter 1 Introduction © National Instruments Corporat ion 1-3 NI PXI-8105 User Manual NI PXI-8105 Functional Description The NI PXI-8105 is a modular PC in a PXI 3U-size form factor. Figure 1-1 is a functional block diagram of the NI PXI-8105. Foll owing the diagram is a description of each logic block show n.
Chapter 1 Introduction NI PXI-8105 User Manual 1-4 ni.com The NI PXI-8105 consists of the following logic blocks on the CPU module and the I/O module. The CPU module has the following logic blocks: • Socket 479 CPU is the socket definition for the Intel ® Core ™ Duo processor T2500.
Chapter 1 Introduction © National Instruments Corporat ion 1-5 NI PXI-8105 User Manual control of NI hardware. I nstru ment driv ers are av ailable at ni.
Chapter 1 Introduction NI PXI-8105 User Manual 1-6 ni.com Y ou can expand the timing an d triggering functi onality of your PXI system with PXI Timing and Synchronization products.
© National Instruments Corporat ion 2-1 NI PXI-8105 User Manual 2 Installation and Configuration This chapter contains information about installing and co nfiguring your NI PXI-8105 controller. Installing the NI PXI-8105 This section contains general inst allation instru ctions for the NI PXI-8105 .
Chapter 2 Installation and Configuration NI PXI-8105 User Manual 2-2 ni.com 4. Remov e the protecti ve plas tic cov e rs from the four bracket-retaining screws as sho wn in Figure 2-1. Figure 2-1. Removing Protective Screw Caps 5. Make sure the injector/ejector handl e is in its downward position.
Chapter 2 Installation and Configuration © National Instruments Corporat ion 2-3 NI PXI-8105 User Manual 7. Raise the injector/ejector handle until th e module firmly seats into the backplane receptacle connec tors. The front panel of the NI PXI-8105 should be ev en with the front panel of the chassis.
Chapter 2 Installation and Configuration NI PXI-8105 User Manual 2-4 ni.com Figure 2 -2 shows an NI PXI-8105 installed in the system controll er slot of a National Instruments PX I-1042 chassis. Y ou can place PXI devices in any other slots. Figure 2-2.
Chapter 2 Installation and Configuration © National Instruments Corporat ion 2-5 NI PXI-8105 User Manual BIOS Setup You can change the NI PXI-8105 configuration settings in the BIOS setup. The BIOS is the low-level interface be tween the hardware and PC software that configures and t ests your hardware when yo u boot the sy stem.
Chapter 2 Installation and Configuration NI PXI-8105 User Manual 2-6 ni.com • <+> and <–> —Use these keys to c ycle be tween all av ailable settings for a selected conf iguration option. • <Tab> —Use this key to select time and date f ields.
Chapter 2 Installation and Configuration © National Instruments Corporat ion 2-7 NI PXI-8105 User Manual Caution Changing settings in this menu may resu lt in an unstable or unbootable controller . If this happens, follow the procedures outlined in the System C MOS section to restore BIOS settings to their factory defaults.
Chapter 2 Installation and Configuration NI PXI-8105 User Manual 2-8 ni.com • Parallel Port Mode —The PC industr y has cr eated se veral different modes of operation for this port over the years. Usually , the default setting works for all applications.
Chapter 2 Installation and Configuration © National Instruments Corporat ion 2-9 NI PXI-8105 User Manual that may be hot-plugged in the Expr essCard slot . This setting is only applicable if ExpressCard Hot-Plug Resources is set to Enabled . The default v alue for this setting is 8 PCI buses.
Chapter 2 Installation and Configuration NI PXI-8105 User Manual 2-10 ni.com Note Scanning for Option ROMs on de vices behind a PCI bridge cannot be disabled. PCI Device x Option ROM Scan —This setting selects whether PCI device x will be scanned for an option ROM.
Chapter 2 Installation and Configuration © National Instruments Corporat ion 2-11 N I PXI-8105 User Manual • USB FDC —A USB based floppy disk driv e. • PCI SCSI —A SCSI driv e (hard disk driv e or CD-R OM) connected through a SCSI controller in the PXI chassis.
Chapter 2 Installation and Configuration NI PXI-8105 User Manual 2-12 ni.com Complete the f ollo wing steps to clear the CMOS contents: 1. Power of f the chassis. 2. Remov e the controller from the chassis. 3. Move the jumper on W7 from pins 1–2 to pins 2 –3, as shown in Figure 2-3.
Chapter 2 Installation and Configuration © National Instruments Corporat ion 2-13 N I PXI-8105 User Manual Drivers and Software Files and Directories Instal led on Y our Hard Drive Your hard dr ive includ es a directory called images in its root that contains software and soft copi es of manuals for the installed devi ces.
Chapter 2 Installation and Configuration NI PXI-8105 User Manual 2-14 ni.com Chassis Configuration Configuration of the PXI system is handled th rough Measurement & Automation Explor er (MAX), incl uded with th e software pre-installed on your controller.
Chapter 2 Installation and Configuration © National Instruments Corporat ion 2-15 N I PXI-8105 User Manual Basic PXI System Conf iguration 1. Launch MAX. 2. In the Configuration tree, click the Devices and Interfaces branch to expand it. 3. If the PXI system contro ller has not yet been configured, it is labeled PXI System (Unidentified) .
Chapter 2 Installation and Configuration NI PXI-8105 User Manual 2-16 ni.com different size modules in each slot is supported, but system performance will be slower than using two matched modules. Ho we ver , tw o mismatched modules will result in better per formance than using a single module.
Chapter 2 Installation and Configuration © National Instruments Corporat ion 2-17 N I PXI-8105 User Manual Hard Drive Recover y NI PXI-8105 controllers include tw o methods of restoring the original factory condition of your hard drive.
Chapter 2 Installation and Configuration NI PXI-8105 User Manual 2-18 ni.com As an alternati ve to a USB CD-R OM dr iv e, you can use an external SCSI CD-R OM with a PXI-SCSI adapter . Note For additional assistance with installing or changing an operati ng system, refer to KnowledgeBas e 2ZKC02OK at ni.
© National Instruments Corporat ion 3-1 NI PXI-8105 User Manual 3 I/O Information Front Panel Connectors Table 3-1 lists various I/O interfaces and their corresponding NI PXI-8105 external connectors, bus interfaces, a nd functions.
Chapter 3 I/O Information NI PXI-8105 User Manual 3-2 ni.com Front Panel Figure 3-1 shows t he front panel layou t and dimensio ns of the NI PXI-8105. Dimensions are in inches [millimeters]. Figure 3-1. NI PXI-8105 Front Panel Layout an d Dimensions 4.
Chapter 3 I/O Information © National Instruments Corporat ion 3-3 NI PXI-8105 User Manual DVI-I Figure 3-2 shows t he location and pi nouts for the DVI-I connector on the NI PXI-8105. Table 3-2 lists and describes the DVI-I conn ector signals. Figure 3-2.
Chapter 3 I/O Information NI PXI-8105 User Manual 3-4 ni.com 11 TMDS Data1/3 Shield 12 Reserved 13 Reserved 14 +5 V Power 15 Ground (for +5 V) 16 Hot Plug Detect 17 TMDS Data0 – 18 TMDSData0+ 19 TMD.
Chapter 3 I/O Information © National Instruments Corporat ion 3-5 NI PXI-8105 User Manual COM1 Figure 3-3 shows the location and pinouts for the COM1 connector on the NI PXI-8105. Table 3-3 lists and describes the COM1 conn ector signal. Figure 3-3. COM1 Connector Location and Pinout Table 3-3.
Chapter 3 I/O Information NI PXI-8105 User Manual 3-6 ni.com Ethernet Figure 3-4 shows the locatio n and pinouts for t he Ethernet connector on t he NI PXI-8105.
Chapter 3 I/O Information © National Instruments Corporat ion 3-7 NI PXI-8105 User Manual Parallel Port Figure 3-5 shows t he location and pi nouts for the IEEE 128 4 (parallel) connector on the NI PXI-8105. Table 3-6 lists and describes the IEEE 1284 connector signals.
Chapter 3 I/O Information NI PXI-8105 User Manual 3-8 ni.com Table 3-6. Parallel Port Connector Signals Pin Default Conf iguration (LPT) Signal Name Signal Description 1 BUSY Device Busy 2 SLCT Select.
Chapter 3 I/O Information © National Instruments Corporat ion 3-9 NI PXI-8105 User Manual Universal Serial Bus Figure 3-6 shows t he location and pi nouts for the Univ ersal Serial Bus (USB) connectors on the NI PXI-8105. Table 3-7 lists and descri bes the USB connector signals.
Chapter 3 I/O Information NI PXI-8105 User Manual 3-10 ni.com Tr i g g e r The TRG connector is the software-c ontrolled trigger connection for routing PXI triggers to or from the backplane tri gger bus. Figure 3-7 shows the TRG connector location on the NI PXI-8105.
Chapter 3 I/O Information © National Instruments Corporat ion 3-11 N I PXI-8105 User Manual GPIB (IEEE 488.2) Figure 3-8 shows t he location and pi nouts for the GPIB co nnector on the NI PXI-8105. Table 3-9 l ists and describes the GPIB connector si gnals.
Chapter 3 I/O Information NI PXI-8105 User Manual 3-12 ni.com ExpressCard/34 Slot The NI PXI-8105 controller is equipped with an ExpressCard/ 34 slot on the front panel, which p rovides I/O ex pansion and options for removab le storage, Ethernet, and a variety of other I/O.
Chapter 3 I/O Information © National Instruments Corporat ion 3-13 N I PXI-8105 User Manual Table 3-10. ExpressCard Connector Signals Pin Signal Name Signal Descri ption 1 GND Ground 2 USBD – USB D.
Chapter 3 I/O Information NI PXI-8105 User Manual 3-14 ni.com Front Panel Features The NI PXI-8105 controller has the following front-panel feat ures: • A controller reset pushbutton (press the butt.
© National Instruments Corporat ion 4-1 NI PXI-8105 User Manual 4 Common Configuration Questions This chapter answers common configuration questions you may have when using the NI PXI-8105 embedded controller.
Chapter 4 Common Configuration Qu estions NI PXI-8105 User Manual 4-2 ni.com • An external USB mass storage device such as a USB hard dri ve or CD-R OM • An external USB floppy dr i ve • Most PCI-based boards that provide an Option R OM Note There are some limitatio ns when boo ting from a USB device.
Chapter 4 Common Configuration Q uestions © National Instruments Corporat ion 4-3 NI PXI-8105 User Manual What if I don’t ha ve a Y -splitter cable? Can I still use a mo use and keyboard? If you do not hav e a Y -splitter cable, plug a USB keyboard into any USB connector .
Chapter 4 Common Configuration Qu estions NI PXI-8105 User Manual 4-4 ni.com How do I install software from a CD? The compact size of the NI PXI-8105 does not allo w for an inte grated CD-R OM dri ve. Y ou ha ve the follo wing options: • USB CD-ROM —Y ou can install from a U SB CD-R OM using a bootable installation CD .
Chapter 4 Common Configuration Q uestions © National Instruments Corporat ion 4-5 NI PXI-8105 User Manual Figure 4-2. Installing a DDR2 SO-DIMM in an NI PXI-8105 Controller How do I flash a new BIOS? Y ou can download the ne w BIOS from ftp.ni.com/support/pxi/ .
Chapter 4 Common Configuration Qu estions NI PXI-8105 User Manual 4-6 ni.com PXI Configuration How do I use the SMB trigger on the fr ont panel? For de tails, refer to th e PXI Features section of Chapter 2, Insta llation and Configuration .
© National Instruments Corporat ion 5-1 NI PXI-8105 User Manual 5 T roubleshooting This chapter answers common troubleshooting quest ions you may have when using the NI PXI-8105 embedded co mputer. What if the NI PXI-8105 does not boot? Sev eral problems can cause a controller not to boot.
Chapter 5 T roubleshooting NI PXI-8105 User Manual 5-2 ni.com My control ler boots f ine until I get t o Windo ws, at which poi nt I cannot read the scr een. This may include garbled output, white screen, black screen, or an out of synch message from the monitor .
Chapter 5 T roubleshooting © National Instruments Corporat ion 5-3 NI PXI-8105 User Manual As an alternativ e method, complete the following steps: 1. Power of f the chassis. 2. Remov e the controller from the chassis. 3. Move the jumper on W7 from pin s 1–2 to pi ns 2–3 as shown in Figure 5-1.
© National Instruments Corporat ion A-1 NI PXI-8105 User Manual A Specifications This appendix lists the electrical , mechanical, and en vironmental specifications of the NI PXI-8105 embedded computer . Electrical Physical Board dimensions ..........
Appendix A Specifications NI PXI-8105 User Manual A-2 ni.com Operating Environment NI PXI-8105 Ambient temperature range .............5 to 50 °C in an NI PXI-1042 chassis (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2). Refer to the datasheet linked from the NI PXI-8105 Embedded Controller product page at ni.
Appendix A Specifications © National Instruments Corporat ion A-3 NI PXI-8105 User Manual Shock and Vibration Operational shock ........ .............. ............ 30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC-60068-2-27. Test profile developed in accordance with MIL-PRF-28800F.
Appendix A Specifications NI PXI-8105 User Manual A-4 ni.com CE Compliance This product meets the essential re quirements of applicable European Directi ves, as amended for CE marking, as follo ws: Low-Voltage Directive (safety) ..............73/23/EEC Electromagnetic Comp atibility Directive (EMC) .
© National Instruments Corporat ion B-1 NI PXI-8105 User Manual B T echnical Support and Professional Ser vices Visit the following sections of the National Instruments Web site at ni.com for technical support an d professional services: • Support —Online technical support resources at ni.
Appendix B T echnica l Support and Professional Services NI PXI-8105 User Manual B-2 ni.com If you searched ni.com and could not find the answers you need, contact your local off ice or NI corporate h eadquarters. Phone numbers for our worldwide of f ices are listed at the front of this manual.
© National Instruments Corporat ion G-1 NI PXI-8105 User Manual Glossar y Symbol Pref ix V alue nn a n o 1 0 –9 µ micro 10 –6 m milli 10 –3 k kilo 10 3 Mm e g a 1 0 6 Gg i g a 1 0 9 Tt e r a 1 0 12 Symbols ° Degrees. Ω Ohms. % Percent. A A Amperes.
Glossary NI PXI-8105 User Manual G-2 ni.com B B Bytes. backplane An assembly , typi cally a printed circuit board, with connectors and signal paths that bus the connector pins. BIOS Basic Input/Output System—BIOS functions are the fundamental le vel of an y PC or compatible computer .
Glossary © National Instruments Corporat ion G-3 NI PXI-8105 User Manual DRAM Dynamic RAM (Random Access Memo ry)—Storage that the computer must refresh at frequent interv als. D VI-I Direct V ideo Interface, Integrated—A video technology enabling the use of both analog and digital video sign als.
Glossary NI PXI-8105 User Manual G-4 ni.com I I/O Input/output—The techniqu es, media, and devices used to achie ve communication between machines and users. IDE Integrated Dri v e Electronics—Har d disk and built-in controller . IEEE Institute of Electrical and Electronics Engineers.
Glossary © National Instruments Corporat ion G-5 NI PXI-8105 User Manual MB Megab ytes of memory . MTBF Mean time between failure. MTTR Mean time to repair . N NI-488 or NI-488.2 The National Instru ments software for GPIB sy stems. NI-D A Q The National Instruments software for data acquisitio n instruments.
Glossary NI PXI-8105 User Manual G-6 ni.com R RAM Random Access Memory—the computer’ s primary workspace. RAMD A C Random Access Memory Digital to Analog Con verter—the VGA controller chip that maintains the co lor palette and con v erts data from memory into analog si gnals for the monitor .
Glossary © National Instruments Corporat ion G-7 NI PXI-8105 User Manual V V V olts. VGA V id eo Graphics Array—The minimu m video display standard for all PC s.
© National Instruments Corporat ion I-1 NI PXI-8105 User Manual Index A Advanced Setup menu, 2-6 A T A-100 IDE logic block, 1-4 B BIOS checking settings, 4-1 flashing new BIOS, 4-5 setup Advanced Set.
Index NI PXI-8105 User Manual I-2 ni.com D data storage, 3-14 DDR SO-DIMMs installing, 2-15 , 4-4 figure, 2-16, 4-5 DDR2 SO-DIMMs from National Instruments (n ote), 2-16, 4-4 Declaration of Conformity.
Index © National Instruments Corporat ion I-3 NI PXI-8105 User Manual installation See also conf iguratio n injector/ejector handle position (caution), 2-2 NI PXI-8105 installed in a PXI chassis (fig.
Index NI PXI-8105 User Manual I-4 ni.com troubleshooting, 5-1 upgrading RAM, 2-15, 4-4 NI resources, B-1 NI support and services, B-1 NI-D A Qmx, 1-5 NI-VISA, 1-6 O operating en vironment specificatio.
Index © National Instruments Corporat ion I-5 NI PXI-8105 User Manual T technical support, B-1 training and certification (NI resources), B-1 trigger, 3-10, 4-6 connector location and pinout (figure).
デバイスNational Instruments PXI NI PXI-8105の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
National Instruments PXI NI PXI-8105をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNational Instruments PXI NI PXI-8105の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。National Instruments PXI NI PXI-8105の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。National Instruments PXI NI PXI-8105で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
National Instruments PXI NI PXI-8105を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNational Instruments PXI NI PXI-8105の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、National Instruments PXI NI PXI-8105に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNational Instruments PXI NI PXI-8105デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。