USER GUIDE SCC-RL Y01 Relay Module The SCC-RLY01 contains on e single-pole double-thro w (SPDT) nonlatching relay capable of switching 5 A at 30 VDC when using an SC-2345 or SC-2350 , or 250 VAC when using an SCC-68. Any single E/M Series DAQ device digital input/output (P0) l ine 0 to 7 can control the SCC-RLY01.
SCC-RL Y01 Relay Module User Guide 2 ni.com bold Bold text denotes items that you must select or click in the software, such as menu items and dialog box options. Bold text also denotes parameter names. italic Italic text denotes variables, emphasis , a cross-reference, or an introduction to a key concept.
© National Instruments Corporation 3 SCC-RL Y01 Rel ay Module User Guide – Documentation for your hardware – Documentation for your software ❑ T o ols – 1/8 in. flathead scre wdri ver – Numbers 1 and 2 Phillips screwdriv ers – W ire insulation stripper Y ou can do wnload NI documents from ni.
SCC-RL Y01 Relay Module User Guide 4 ni.com Figure 1. SCC-RL Y01 Circuit Diagram Caution When connecting signals >60 VDC to th e SCC-RL Y01 module in the SCC-68, you must use the high-voltage backshell. Figure 2 shows the high-voltage backshell. Figure 2.
© National Instruments Corporation 5 SCC-RL Y01 Rel ay Module User Guide Caution The SCC-RL Y01 module is derated to 30 V maximum switching voltage in the SC-2345 carrier regardless of any other v oltage markings found on the SCC-RL Y01 module case. Signal bandwidth.
SCC-RL Y01 Relay Module User Guide 6 ni.com I/O connectors ............... .............. ............One 20-pin right-angle male connector One 3-pin screw-term inal block Field-wiring diameter ........... ......... .........28 to 16 AWG Maximum W orking Voltage Maximum working voltage refers to the signal voltage plus the common-mode vo ltage.
© National Instruments Corporation 7 SCC-RL Y01 Rel ay Module User Guide Safety This product meets the requirements of the follow ing standards of safety for electrical equipment for measurement, con.
SCC-RL Y01 Relay Module User Guide 8 ni.com Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible man ner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.
National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for mor e informat ion about Nationa l Instruments trademarks. Other product and compan y names mentioned herein are trademarks or trade names of their respective companie s.
デバイスNational Instruments SCC-RLY01の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
National Instruments SCC-RLY01をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNational Instruments SCC-RLY01の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。National Instruments SCC-RLY01の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。National Instruments SCC-RLY01で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
National Instruments SCC-RLY01を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNational Instruments SCC-RLY01の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、National Instruments SCC-RLY01に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNational Instruments SCC-RLY01デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。