Operation Manual LRM 2200SI LASER RANGE FINDER MONOCULAR 105 Sparks Ave., Toronto, ON M2H 2S5, Canada.
ii.
iii IMPORTANT INFORMATION Read prior to activa tion You have ju st purc hased a sophisti cated electro- optical de vice that emits i nvisible l aser radiat ion.
iv Caution - use of optical instrum ents such as binoculars, loupes, mirrors, lenses , etc. wi th this product increases eye hazard Avoid eye exposure to direct la ser beam or its close reflec.
TABLE OF CONTENTS 1. BRIEF DESCRIPTIO N ............................................. 2 Principle of operation .......................................................... 2 Key Featur es .....................................................
2 10. CUSTOMER SUP PORT ......................................... 24 11. QUAL ITY CERTIFICATE ..................................... 25 CAREFULLY READ ALL THE INSTRUCTIONS BEFORE USING THE UNIT ! FAILURE TO OBEY THE INSTRUCTIONS WILL VOID THE WARRANTY AND MA Y CAUSE INJURY! 1.
3 measurement allows height ca l culation. The unit m easures azimuth simultaneously as we ll. Speed o f an object m oving closer or further from the unit can also be calculated using the time-of-flight pri nciple.
4 2 3 4 5 6 7 1 8 2. DEVICE APPEARANCE Fig. 1. Front view 1 - Eyepiece 2 - Objective lens 3 - Laser em itter lens 4 - Receiver lens 5 - M (Mo de) butto n 6 - A (Acti on) but ton 7 - Body of the de vic.
5 Fig.2. Rear view 1 - Eyepiece 10 - Tripod socket 9 - Battery compartment cover 12 - Classification 11 - Identification imprint imprint, shown below 9 11 1 12 10.
6 3. DELIVERY SET Standard delivery set LRM 2200SI is supplied in a set comprised of the following: Qty LRM 2200SI 1 9V Lithium (non-magnetic) battery 1 Soft carrying c ase Cleaning cloth 1 1 Neck str.
7 4. SPECIFICATION S Optics Magnificatio n Objective lens diameter Exit pupil diameter Field of view Type of coating 7x 25 mm 3.6 mm 8 Fully multi-coated optics Range Finder Laser Measuring range .
8 Inclinometer Measuring elevation range ±80 o Accuracy ±1 o Speed Detector Measured spee d range 5-400 km /h Accuracy ±2 km/h Power Battery 9V Lithium (non-magnetic) Battery capacity Min 5,000 mea.
9 5. OPERATION INSTRUCTIONS 1 – Low battery indi cator 2 – Reticle (either -¦- or ) 3 – Units of measurem ent 4 – Measurement resul t 5 – Target q uality i ndicator 6 – Lase r active indicat or 7 – Setup m ode indicat or 8 – Ready mode indicat or 4 6 2 1 5 3 8 7 Fig.
10 Changing b attery To install a battery: Slide the battery compartm ent cover down (Fig. 2) Install the battery, observing correct polarity Do not force the battery while placing back inside the compartment.
11 Measuring procedure When the unit is powered off the LCD will appear blank . To activate the unit p ress and hold A bu tton (Fig. 1) for half a second. The word ‘READY’ will appear on the display to indicate the unit is powered on. Pressing the A button (Fi g.
12 surface is more reflective tha n a ro ugh one. L arger targets reflect better than small ones. Ranging a target perpend icular to the laser beam provides better results th an the one positioned under a sharp angle to the beam . Weather con ditions that influen ce air tra nsparency (rain, fog, snow, mist) reduce maximum range.
13 Note: Even with target selection logic the unit may not always be able to range the desired target as its reflectivity may be too low to produce enough laser beam refl ections for statistically reliable calculation. A warning will be displayed if th e result is not statistically reliable.
14 o Distance from meters to yards o Speed from km/h to m ph 2 rEc – allows data recall of the last 10 m easurement results: o CLr – Clears all measurem ents SEt – allows the user to sel.
15 calibration simi lar to one conducte d during pro duction pro cess. To perform the accuracy correction, select corr from the CAL menu. Perform correc tion accor ding to re quired measurement parame.
16 Magnetic Nort h (not True Nort h). If the unit detect s large installation errors (u nit is not well levelled or not aimed to the North), then LCD will show resu lt “444” and “99”, which means that correction was not pe rformed d ue to incorrect set up.
17 Minimal gating distance of 000 m will be initially set, further pressing M button will increase gating distance by 100 m up to 2,100 m. When the de sired distance is reached – select it by pressing Action button. OVER 100M – indicates that gating is active To deactivate gating choose gating v alue zero or switch to the default m ode.
18 measured in the Scan ning m ode, though both will be quickly displayed, the second one m ay be di fficult to register by e ye. Nevertheless all data is recorded and may be recalled (see Data Recall mode for details.) Data Recall mode In Data Recall mode results of the last 10 measurements can be displayed.
19 Pressing A button at any moment within the list of recalled results brings the unit to Ready to Measure mode. Choosing cLr at the end of recalled data will erase the device memory.
20 6. BEST MEASURING TECHNIQUE Laser range finder measures di stance by catching laser beam reflected from the target. Ever ything that improves reflection increases the measurement reliability and maximum range. 1. Use tripod when ranging remote targ ets.
21 7. STORAGE AN D MAINTENANCE The unit is a s ophisticated precisi on optical i nstrument equi pped with laser and electronics. Ther efore, it should be handled with due care. Keep away from direct sunlight. Avoid impacts, jolts, dust, moisture, and sharp changes of temperature.
22 8. TROUBLESHOOTING The ranging does not work. The displa y is transparent. Check the charge of the battery. Replace it if it is weak. The ranging mode does n ot work. The display shows res ults of the last measurement or is transp arent. Wait for 16 second s, and press the Actio n button again.
23 9. WARRANTY NEWCON warrants this product against defects in m aterial and workmanshi p for one year from the date of the ori ginal pur chase. Longer warranty is available, subject to the terms of the specific sales contract.
24 10. CUSTOMER SUPPORT Should you experien ce any difficulties with your NEWCON OPTIK product, consult this manual first. If the problem remains unresolved, c ontact our cust omer suppo rt departm ent at (416) 663-6963 or toll f ree at 1-877-368-6666 .
25 11. QUALITY CERTI FICATE The unit has passed the quality inspection. Production date Serial number Quality Inspector Purchase date.
26.
27.
NEWCON OPTIK Printed in Canada R1 – 02.12.
デバイスNewcon Optik LRM 220SIの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Newcon Optik LRM 220SIをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNewcon Optik LRM 220SIの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Newcon Optik LRM 220SIの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Newcon Optik LRM 220SIで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Newcon Optik LRM 220SIを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNewcon Optik LRM 220SIの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Newcon Optik LRM 220SIに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNewcon Optik LRM 220SIデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。